You are on page 1of 4

2/13/2019 Detailing

Detailing
The actual process of detailing has not changed dramatically. However, many detailed provisions are di erent to those that were in BS 8110.

The main reference for detailing is the IStructE Standard Method of Detailing Structural Concrete, 3rd edition, which is named as NCCI in the
UK National Annex. Guidance can be found in Chapter 10 (Detailing) of How to Design Concrete Structures using Eurocode 2. The main
issues are discussed here.

Cover

The nominal cover should generally be speci ed by the designer (See 'How to Design Concrete Structures using Eurocode 2': Chapter 2,
Getting Started). The nominal cover should be shown on the drawings and should refer to the reinforcement nearest to the surface of the
concrete e.g. the links in a beam. The cover to the main bar should be at least equal to the size of that bar, plus the allowance for deviations,
cdev which is usually 10 mm depending on the quality assurance. In high exposures nominal covers will be greater.

Anchorage and lap lengths

Eurocode 2 introduces a range of factors (1 to 6) for use when calculating the appropriate anchorage and lap lengths. A number of
assumptions can be made that enable the Table 2 (below) to be developed for anchorage and lap lengths.

If the conditions noted in the table are not met then reference should be made to Eurocode 2. Lap lengths for unequal size bars may be
based on the smaller bar.

The top of sections > 250 mm thick and the top 300 mm of sections deeper than 600 mm are considered to provide poor bond conditions.
In these locations, bond strengths are reduced and anchorage and lap lengths are increased accordingly.

Eurocode 2 states that where possible laps in a member should be staggered and not located in areas of high stress. The arrangement of
lapped bars should comply with 'How to Design Concrete Structures using Eurocode 2': Detailing, see Figure 5.

Table 2: Anchorage and lap lengths for concrete class C25/30 (mm) 

 Extract from How to Design Concrete Structures using Eurocode 2: Detailing (page 90, Table 2)

Tension laps

https://www.concretecentre.com/Concrete-Design/Design-Codes/Eurocode-2/Detailing.aspx 1/4
2/13/2019 Detailing
Transverse tensile stresses occur at the ends of lapped bars. Where the diameter, f, of the lapped bars needs to be more than 20 mm
diameter transverse bars (i.e. links) should be provided close to the ends of the lapped bars.

Curtailment

Longitudinal reinforcement should be extended beyond the point at which it is no longer required for exural strength by a distal al which
may calculated or conservatively be taken as al = 1.125d (this is known as the ‘shift rule’).  Simpli ed rules are shown in Figures 8 and 10
below.

Figure 8: Simpli ed detailing rules for beams

Extract from How to Design Concrete Structures using Eurocode 2: Detailing (Page 92, Figure 8)

https://www.concretecentre.com/Concrete-Design/Design-Codes/Eurocode-2/Detailing.aspx 2/4
2/13/2019 Detailing

Figure 10: Simpli ed detailing rules for slabs

Extract from How to Design Concrete Structure using Eurocode 2: Detailing (Page 94, Figure 10) 

Punching shear reinforcement

There are detailed rules for punching shear reinforcement.

Detailing minima and maxima

The clauses and values for most detailing minima and maxima are given in Table 1 below:

Table 1 Detailing minima and maxima according to Eurocode 2

Item                                      EC2 Clause / Values


Beams                                   
Main Bars in Tension           
As,min                                       9.2.1.1 (1):    0.26 fctm/fykbd  ³ 0.0013 bd
As,max                                      9.2.1.1 (3):    0.04 bd
Main Bars in Compression
As,max                                      9.2.1.1 (3):    0.04 bd
Spacing of Main Bars           
smin                                         8.2 (2):         dg + 5 mm or f or 20mm
Smax                                         Table 7.2N or Table 7.3N
Links                                      
Asw,min                                     9.2.2 (5):    (0.08 b s Öfck)/fyk
sl,max                                       9.2.2 (6):    0.75 d
st,max                                       9.2.2 (8):    0.75 d £ 600 mm
st,maxcompression                            9.2.1.2 (3)  15f
 Slabs

https://www.concretecentre.com/Concrete-Design/Design-Codes/Eurocode-2/Detailing.aspx 3/4
2/13/2019 Detailing
Main Bars in Tension
As,min                                       9.2.1.1 (1):  0.26 fctm/fykbd  ³ 0.0013 bd
As,max                                      9.2.1.1 (3):  0.04 bd
Secondary Transverse Bars
As,min                                       9.3.1.1 (2): 0.2As for single way slabs
Spacing of Bars                     
smin                                         8.2 (2):    dg + 5 mm or f or 20mm
Smax                                         9.3.1.1 (3): main 3h £ 400 mm
                                                             secondary: 3.5h £ 450 mm
                                                              in places of maximum moment:
                                                                   main:  2h £ 250 mm
                                                                   secondary: 3h £ 400 mm
 Punching shear links
Asw,min                                     9.4.3 (2): Link leg = 0.053sr st Ö(fck)/fyk
Sr                                            9.4.3 (1):    0.75d
St                                            9.4.3 (1):    within 1st control perim.:  1.5d
                                                                      outside 1st control perim.:  2d
Columns                                
Main Bars in Compression
As,min                                       9.5.2 (2):   0.10NEd/fyk £ 0.002bh
As,max                                      9.5.2 (3):   0.04 bh
Links                                      
Min size                                 9.5.3 (1) 0.25f or 6 mm
Scl,tmax                                     9.5.3 (3): generally MIN (20fmin; b;  400 mm)
                                                               but within h of a slab or beam or in lap lengths MIN(12fmin; 0.6b; 240 mm)
                                               9.5.3 (6): No compression bar > 150 mm from a restrained bar

https://www.concretecentre.com/Concrete-Design/Design-Codes/Eurocode-2/Detailing.aspx 4/4