You are on page 1of 17

EQUIPMENT DATA SHEET

SW-CC HEAD TANK

SW-CC HEAD TANK PROCESS DATASHEET

B 13/April/17 Re-Issued for Internal Review PBN


GPS

A 01/Mar/17 Issued for Internal Review JAT PBN GPS


PRE CHK APP
REV DATE DESCRIPTION
COMPANY
TOTAL OR PARTIAL REPRODUCTION AND/OR UTILIZATION OF THIS DOCUMENT ARE FORBIDDEN WITHOUT PRIOR WRITTEN
AUTHORIZATION OF PT. WIJAYA KARYA Tbk.
PROYEK PEMBANGUNAN PABRIK FERONIKEL HALMAHERA TIMUR (P3FH)
Contract No: 430/92/DAT/2016 Item No: -
Document No. :

P3FH-PR-4222-PDS-1001-RB
2

EQUIPMENT DATA SHEET

SW-CC HEAD TANK

TABULATION OF REVISION SHEET

REVISION REMARKS REVISION REMARKS


SHEET SHEET
0 1 2 3 4 5 0 1 2 3 4 5
1 44
2 45
3 46
4 47
5 48
6 49
7 50
8 51
9 52
10 53
11 54
12 55
13 56
14 57
15 58
16 59
17 60
18 61
19 62
20 63
21 64
22 65
23 66
24 67
25 68
26 69
27 70
28 71
29 72
30 73
31 74
32 75
33 76
34 77
35 78
36 79
37 ATTACHMENT
38 1

P3FH-PR-4222-CAL-1001 – Rev. B Page 2 of 9


3
39 2
40 3
41 4
42 5
43 6

P3FH-PR-4222-CAL-1001 – Rev. B Page 2 of 9


EQUIPMENT DATA SHEET

SW-CC HEAD TANK

REVISION SHEET DESCRIPTION

NO PAGE SUBJECT DESCRIPTION OF CHANGE REV.

P3FH-PR-4222-CAL-1001 – Rev. B Page 3 of 9


EQUIPMENT DATA SHEET

SW-CC HEAD TANK

REVISION SHEET DESCRIPTION

1 Table of Revision Sheet ...….…....….…………………………………………………………….. 2

2 Revision Sheet Description ...….…....….………………………………………………………… 3

3 Table of Content...….…....….………………………………………………………………………. 4

4 Reference Documents…………………………...…………………………………………………. 5

5 Data Sheet Lists…………………………...………………………………………………………….. 6

6 General Note…..………………………...…………………………………………………………….. 7

7 SW-CC Head Tank Datasheet (sheet 1)…....…….….……………...………………… 8

8 SW-CC Head Tank Datasheet (sheet 2)…....…….….……………...………………… 9

P3FH-PR-4222-CAL-1001 – Rev. B Page 4 of 9


EQUIPMENT DATA SHEET

SW-CC HEAD TANK

REFERENCE DOCUMENTS

ANTAM ENGINEERING STANDARD

CODES AND STANDARDS

API 650 Welded Steel Tank for Oil Storage

JIS B2220 Steel Pipe Flanges

ASTM American Society for Testing and Material

Tata cara perencanaan ketahanan gempa untuk struktur


SNI-03-1726-2012
bangunan gedung dan non gedung

PROJECT DOCUMENTS

P3FH-PR-4000-DBS-1001 Proses Design Basis

P3FH-PR-4000-DBS-1002 Process Description

P3FH-PR-4222-CAL-1001 – Rev. B Page 5 of 9


EQUIPMENT DATA SHEET

SW-CC HEAD TANK

DATA SHEET LIST

REV ITEM NO. TAG NUMBER EQUIPMENT TYPE PAGE

A 1 4222-1 SW-CC Head Tank 1 8-9

A 2 4222-2 SW-CC Head Tank 2 8-9

A 3 4222-3 SW-CC Head Tank 3 8-9

P3FH-PR-4222-PDS-1001-REV.B Page 6 of 9
EQUIPMENT DATA SHEET

SW-CC HEAD TANK

GENERAL NOTES

1. VTA: Vendor to Advise, N/A: Not Applicable

2. Shell, bottom and roof thickness are minimum. Vendor shall check and guarantee them on strength.

3. Vendor to design tank stiffener for shell and roof and shall guarantee them on strength..

4. Vendor to design ladder with cage for access to tank roof.

5. All information marked with VTA (vendor to advise) on this form shall be filled in by the vendor at quotation stage.

6. Name plate shall be stainless steel

7. Nozzle necks in accordance with API 650 or other related standard

8. Vent with mesh and level indicator are to be supplied by Tank Vendor.

P3FH-PR-4222-PDS-1001-REV.A Page 7 of 9
EQUIPMENT DATA SHEET

DATA SHEET OF TANK

1 GENERAL INFORMATION
2 Tag Number: 4222-1, 4222-2, 4222-3 Quantity :
3 Location: Indoor X Outdoor Fluid Contained/Processed:
4 Hazardous Considerations Yes X No
5 Pressure Cyclic Yes X No, but variable level
6 Temperature Cyclic Yes X No
7
8 PROCESS SERVICE CONDITION
9 Operating Conditions Normal Pressure: Atmospheric
10 Operating Temperature: Ambient Design Temperature:
11 Product Stored : Water Specific Gravity:
12 Site Conditions Wind speed (m/s): 40 Earthquake factor:
13

14 TECHNICAL DATA

15 Code: API 650


16 Bottom Thickness (incl. CA): min. 8 mm Bottom Type Flat
17 Shell Thickness (incl. CA): min. 6 mm
18 Roof Thickness (incl. CA): min. 6 mm Roof Type Flat Umbrella/Dome
19 Slope 1/12 Cone Roof
20 Corrosion Allowance (CA) : 1.5 mm (Bottom / Shell)
21 Corrosion Allowance (CA) : 1 mm (Roof)
22
23
24 Fabrication / Construction Details
25 Tank Capacity (m3): 300
26 Tank Dimensions (mm): 9,500 inside dia X 4,500 height
27 Frangible Roof Joint No
28 Top Angle Turned Out In
29 Access Type Circular Stair Free Standing Stair
30 Heating Coil No Yes, Surface Area: sq m
31 Material Specifications
32 Shell, Bottom, Roof : A283 Gr.C
33 Structurals : A283 Gr.C
34 External Bolt/Nut: ASTM A193 Gr.B7/A194 Gr.2H or Eq
35 External Coating system Refer to Painting Specification

P3FH-PR-4222-PDS-1001-REV.B Page 8 of 9
36 Stress Relieving: No Yes
37 Personal protection No Yes
38 Insulation No Yes
39 Radiograhpy Spot Full
40 Hydrotest Full Water
41
42 General Note:
43 - Refer to previous sheet
44
45
46
47
48
49
50
51
52
53
54
55
56
57

58
59

P3FH-PR-4222-PDS-1001-REV.B Page 8 of 9
QUIPMENT DATA SHEET

DATA SHEET OF TANK

3 Units
Fluid Contained/Processed: Softened Water - Copper Cooling (SW-CC)

30 ° Celcius Minimum Temperature: 23 ° Celcius


1.000 Heating System : N/A
0.4 G Standard: SNI-03-1726-2012

Inward Slope 10° Outward Slope

Umbrella/Dome Supported Self-Supporting with Rafter


Cone Roof

Ladder with cage


Yes, Surface Area: sq m

Nozzles: - Flange ASTM A105 or Eq


- Neck ASTM A106 / A283 Gr.C / JIS SS400
Gasket : Non asbestos joint sheet

P3FH-PR-4222-PDS-1001-REV.B Page 8 of 9
P3FH-PR-4222-PDS-1001-REV.B Page 8 of 9
EQUIPMENT DATA SHEET

SW (CC) HEAD TANK

1 TANK SKETCH
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
A
19
20
21
22 B
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
P3FH-PR-4222-PDS-1001-REV.B Page 9 of 9
38
39
40
41
42
43
44
45
46
47 Note: - Nozzle orientation to be confirmed with piping design
48
49 CONNECTION SCHEDULE
50 Mark QTY Size. Rating Facing Standard
51 No. Reqd. (mm).
52
53
54
55
56 N07 A/B 2 40A 10K FF JIS B2220
57 N06 1 40A 10K FF JIS B2220
58 N05 1 350A 10K FF JIS B2220
59 N04 1 200A 10K FF JIS B2220
60 N03 1 200A 10K FF JIS B2220
61 N02 1 600 A 10K FF JIS B2220
62 N01 1 600 A 10K FF JIS B2220
63 MH2 1 500A API 650
64 MH1 1 500A API 650

P3FH-PR-4222-PDS-1001-REV.B Page 9 of 9
EQUIPMENT DATA SHEET

SW (CC) HEAD TANK

P3FH-PR-4222-PDS-1001-REV.B Page 9 of 9
NNECTION SCHEDULE
Description Remarks

Level Gauge
Level Gauge
Vent with bug screen/mesh
Drain
Overflow with internal pipe
Water Inlet with internal pipe
Water Outlet
Roof Manhole
Shell Manhole

P3FH-PR-4222-PDS-1001-REV.B Page 9 of 9