You are on page 1of 2

PROCEDURE FOR BTS-240XL-II COMMISSIONING under BR9.

0 --July 21, 2008


Start  Programs  LMT291_1_18_02  Start LMT Author: Anjit Rajkarnikar
LMT Control Center window will appear
Wait for LOGON to become dark blue
Click on logon
Enter the Username: SAG
Enter Password: SAG
Connect and close

Click on Input handler


1. Download Software
Managed Element  Software Management
Double click on Software management  DNLALL.EXE
SRCPATH---c:\SW\BTSPLUS\HS011818.SWL (Command viewer: Dnlall.exe window will appear)
Overwrite yes (It will take 10 mins.) and after completion of download
2. Software Activation
Managed element  BSS functional BTSM (Double click)  Activate BTSM
BTSM: 0
FileID: HS011818.SWL (copy from relnotes.txt and paste)
FileSWV: 01-04-18-01-18-07_08-04-03 (copy from relnotes.txt and paste)
After giving activate SW BTS will ask for login again.
BTS will be in phase2
3. Creation as per Configuration
 BTSEP  Double click on Rack  Set Rack
Vendna: NSN / TypRack: BS240XL and Submit
 BPORT  CREATE BPORT
NAME: BPORT: 0 / L1PT: PCM30 CRC4 / LCONF: STAR/MULTI/ LOOP (as instructed)
BER : LOWER: E10_6 / UPPER: E10-3 ; L1RAT= Protocol signalling
LAPDLE  CREATE LAPDLE
NAME: LAPDLE: 0 (signaling cut off 32 channels) / LAPDCH: BPORT: BPORT0
TSL: 31 (Depending on SITE LINKAGE, 30 for Multidrop) / SSL: FULL_64KB
 BTSE  SETBTSEP
SALUNAM: NE346… (Shelf unique name as given in the BTS paper) For identification of the site in BSC.
Vendname: NSN
BTSM SETBTSM  TEI: 0 (Limited up to 63)
Create COSA
FCUMAIN  CREATE FCUMAIN (As equipped)
Eg: CREATE FCUMAIN [BASICS]: NAME:FUCMAIN:0&&11 FCUMODE: doubleCUMode
(Create FCU:1,3,4,5,6,7.After which lock and delete CUs which are not present asFCUs:0,2,8,9,10,11 in our config.)
 FCUTR CREATE FCUTR [BASICS] NAME: FCUTR: 0&&23
(Create FCUTR as: 2*FCU, 2*FCU+1 or delete those from 24 FCUTRs if not required)
DUVSWR CREATE DUVSWR (as equipped)
Creation of BTS-240XL -II with 4:2 combiners
CREATE DUVSWR: NAME=DUVSWR: 0 CELL NO=0 COMBMD=FourToTwo, WDDUVSWR=FCUMAIN4TX0 FCUMAIN5TX0
(Depending on the cable connections of CUs to DUAMCO)
CREATE DUVSWR: NAME= DUVSWR: 1 CELL NO=0 COMBMD=FourToTwo, WDDUVSWR= FCUMAIN4TX1 FCUMAIN5TX1

CREATE DUVSWR: NAME=DUVSWR: 10 CELL NO=1 COMBMD=FourToTwo, WDDUVSWR=FCUMAIN3TX0 FCUMAIN1TX0


CREATE DUVSWR: NAME=DUVSWR: 11 CELL NO=1 COMBMD=FourToTwo, WDDUVSWR=FCUMAIN3TX1 FCUMAIN1TX1

CREATE DUVSWR: NAME=DUVSWR: 4 CELL NO=2 COMBMD=FourToTwo, WDDUVSWR=FCUMAIN6TX0 FCUMAIN7TX0


CREATE DUVSWR: NAME=DUVSWR: 5 CELL NO=2 COMBMD=FourToTwo, WDDUVSWR=FCUMAIN6TX1 FCUMAIN7TX1

DULNA  CREATE DULNA (as equipped)

CREATE DULNA: NAME=DULNA: 0 CELL NO=0 COMBMD=FourToTwo, WDLNA=FCUMAIN4N FCUMAIN4N1 FCUMAIN5N FCUMAIN5N1
CREATE DULNA: NAME=DULNA: 1 CELL NO=0 COMBMD=FourToTwo, WDLNA= FCUMAIN4D FCUMAIN4D1 FCUMAIN5D FCUMAIN5D1

CREATE DULNA: NAME=DULNA:10 CELL NO=1 COMBMD=FourToTwo, WDLNA= FCUMAIN1N FCUMAIN1N1 FCUMAIN3N FCUMAIN3N1
CREATE DULNA: NAME=DULNA: 11 CELL NO=1 COMBMD=FourToTwo, WDLNA= FCUMAIN1D FCUMAIN1D1 FCUMAIN3D FCUMAIN3D1

CREATE DULNA: NAME=DULNA: 4 CELL NO=2 COMBMD=FourToTwo, WDLNA= FCUMAIN6N FCUMAIN6N1 FCUMAIN7N FCUMAIN7N1
CREATE DULNA: NAME=DULNA: 5 CELL NO=2 COMBMD=FourToTwo, WDLNA FCUMAIN6D FCUMAIN6D1 FCUMAIN7D FCUMAIN7D1

FANP  CREATE FANP (0TO 5 FOR BS240 AND 0 TO 7 FOR BS240XL)


For example: CREATE FAN: NAME=RACK: 0/FAN: 0&&7;
Creation of external alarm ENVABTSE
For Example:
CREATE ENVABTSE: NAME=RACK: 0/ENVABTSE: 2, INTINF=low, ASEV=CRITICAL, ASTRING= “MAINS FAILURE”;
CREATE ENVABTSE: NAME=RACK: 0/ENVABTSE: 3, INTINF=low, ASEV=MAJOR, ASTRING= “DC RECTIFIER FAIL”;
CREATE ENVABTSE: NAME=RACK: 0/ENVABTSE: 4, INTINF=HIGH, ASEV=MAJOR, ASTRING= “TEMPERATURE”;

INTEGRATION
Managed element BSS functional  Double click on BTSM  set BTSM: ABISLKSA: Terrestrial connection, TEI: 0
Managed element BSS functional  Double click on BTSM CONNBSC
Now Login again, BTS should be PH3

Set SW load safety


HS011692.SWL: 01-04-16-01-87-00_04-09-09
Get BTSM unlocked.

Color Combination of PCM Cable for BTS

===============================================

5 4 3 2 1
Tx: PURPLE GREEN gnd Gnd gnd

Rx: WHITE BLUE

In DDF

Blue - White (RX) || Green - Purple (Tx)

=====================================================

In BTS –BPORT

Green | Purple (Tx) Green purple

Blue | White (RX) Orange White

In Multidrop COnfig of BTS:

Cretae BPORT0 & BPORT1 in the Master BTS(Say BTS900)

Bport 0---TSL 31
Bport 1--TSL 30

Note:
Module OVPT is the interface module between the BSC and the BTSE (for the outdoor
versions in common with WAVEs,NTs or CSUs). Therefore, if a failure of the Abis link
is reported, the OVPT must be considered.!

When the OVPT fails, the PCM-line is also broken also for all subsequent BTSE, in the
event of a multidrop configuration.

Alarm Creation in BTS:

ENVABTSE: 2Mains failure


ENVABTSE: 3 rectifier
ENVABTSE: 4temperature