SUBMITTAL MH026FNCA FJM 9,000 Btu/h Wall Mount
Job Name Location
Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #
Quietside 8750 Pioneer Blvd, Santa Fe Springs CA 90670 Tel : 562 699 6066, Fax : 562 699 4351
6 Pine Hill Dr, Carlisle PA 17013 Tel : 717 243 2535, Fax : 717 243 7917
www.quietside.com
Due to Samsung's policy of on-going product development specifications are subject to change without notice SUB-SAMNFORTE09 01/2008
SUBMITTAL MH035FECA FJM 12,000 Btu/h Slim Duct
Job Name Location
Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #
Quietside 8750 Pioneer Blvd, Santa Fe Springs CA 90670 Tel : 562 699 6066, Fax : 562 699 4351
6 Pine Hill Dr, Carlisle PA 17013 Tel : 717 243 2535, Fax : 717 243 7917
www.quietside.com
Due to Samsung's policy of on-going product development specifications are subject to change without notice SUB-SAMFJMDUCT12 01/2008
SUBMITTAL MH035FNCA FJM 12,000 Btu/h Wall Mount
Job Name Location
Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #
Quietside 8750 Pioneer Blvd, Santa Fe Springs CA 90670 Tel : 562 699 6066, Fax : 562 699 4351
6 Pine Hill Dr, Carlisle PA 17013 Tel : 717 243 2535, Fax : 717 243 7917
www.quietside.com
Due to Samsung's policy of on-going product development specifications are subject to change without notice SUB-SAMNFORTE12 01/2008
SUBMITTAL MH050FXCA2A Dual Zone Outdoor
Job Name Location
Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #
Specifications
General
Max Connected Capacity (Btu/h) 24,000
SEER Dependant on Indoor
Min Cooling Capacity (Btu/h) 6000.0
HSPF Dependant on Indoor
Heating COP Dependant on Indoor
Min Heating Capacity (Btu/h) 7,200
Refrigerant Type R410A
De-Hum (Pints/Hr) N/A
Power Voltage 208/230V-1Ph-60Hz Construction
Breaker Size 25A Outdoor unit shall be galvanized steel with a
RLA Cooling/Heating (Amps) 8.6/9.0A baked on powder coated finish for durability
Controls DDC
Heat Exchangers
Outdoor Unit MH050FXCA2A The heat exchangers shall be mechanically bonded fin
Outdoor Noise Level (Db) 50/51 to copper tube.
Width (Inches) 34 5/8"
Height (Inches) 25 1/8" Refrigerant System
Total Depth (Inches) 12 1/4" Compressor shall be a single hermetically sealed DC
Weight (lbs) 131 Inverter drive rotary type
Refrigerant shall be R410A.
Line Sets Refrigerant flow to each Indoor unit shall be controlled
Size 1/4" & 3/8" x 2 by Electronic Expansion Valve. Maximum of 2 Indoor
Max Line Set Length inc 100ft units can be connected to this unit
Max Vertical Separation of 50ft
Max Individual line set length 75ft Rated Matches
Charged with R410A for 25ft Unit can be matched as follows
Addl R410A charge required 0.2oz/ft over 25ft 2 x MH026 units either Neo Forte or Slim Duct
1 x MH026 + 1 x MH035, either neo Forte or Slim Duct
Certifications 2 x MH035 units either Neo Forte or Slim Duct
Safety UL & Ulc Using a single Indoor unit is not allowed
Performance ARI Certified
ARI Certification Reference # TBA Outdoor Fan
The outdoor unit fan shall be a propeller type driven
Warranty 5 Years Compressor by a single BLDC fan motor for optimum efficiency and
3 Years Parts accurate head pressure control
120 Days ltd labor
Controls
Options 25 or 50ft Line Sets Control signal shall be a DDC type signal
Condenser Brackets Controls shall integrate with a BMS system
Control wiring shall require 16AWG shielded wire
Unit operating range shall be
Cooling 23 DegF to 115 DegF
Heating 5 DegF to 75 DegF
Quietside 8750 Pioneer Blvd, Santa Fe Springs CA 90670 Tel :562 699 6066, Fax :562 699 4351
6 Pine Hill Dr, Carlisle PA 17013 Tel : 717 243 2535, Fax : 717 243 7917
www.quietside.com
Due to Samsung's policy of on-going product development specifications are subject to change without notice
SUB-SAMMH050 04-08
SUBMITTAL MH052FECA FJM 18,000 Btu/h Slim Duct
Job Name Location
Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #
Quietside 8750 Pioneer Blvd, Santa Fe Springs CA 90670 Tel : 562 699 6066, Fax : 562 699 4351
6 Pine Hill Dr, Carlisle PA 17013 Tel : 717 243 2535, Fax : 717 243 7917
www.quietside.com
Due to Samsung's policy of on-going product development specifications are subject to change without notice SUB-SAMFJMDUCT18 01/2008
SUBMITTAL MH052FNCA FJM 18,000 Btu/h Wall Mount
Job Name Location
Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #
Quietside 8750 Pioneer Blvd, Santa Fe Springs CA 90670 Tel : 562 699 6066, Fax : 562 699 4351
6 Pine Hill Dr, Carlisle PA 17013 Tel : 717 243 2535, Fax : 717 243 7917
www.quietside.com
Due to Samsung's policy of on-going product development specifications are subject to change without notice SUB-SAMNFORTE18 01/2008
SUBMITTAL MH080FXCA4A Quad Zone Outdoor
Job Name Location
Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #
Specifications
General
Max Connected Capacity (Btu/h) 36,000
SEER Dependant on Indoor
Min Cooling Capacity (Btu/h) 6,500 to 31,700
HSPF Dependant on Indoor
Heating COP Dependant on Indoor
Min Heating Capacity (Btu/h) 8500.0
Refrigerant Type R410A Construction
De-Hum (Pints/Hr) N/A Outdoor unit shall be galvanized steel with a
Power Voltage 208/230v-1Ph-60Hz baked on powder coated finish for durability
Breaker Size 25A
RLA Cooling/Heating (Amps) 12.3/12.6A Heat Exchanger
Control Voltage DDC The heat exchanger shall be mechanically bonded fin
to copper tube.
Outdoor Unit MH080FXCA4A
Outdoor Noise Level (Db) 55/55 Refrigerant System
Width (Inches) 34 5/8" Compressor shall be a single hermetically sealed DC
Height (Inches) 31 3/8" Inverter drive rotary type
Total Depth (Inches) 12 1/4" Refrigerant shall be R410A.
Weight (lbs) 156 Refrigerant flow to each Indoor unit shall be controlled
by Electronic Expansion Valve. Maximum of 4 Indoor
Line Sets units can be connected to this unit
Connection Sizes 1/4" x 3/8" x 2
1/4" x 1/2" x 2 Rated Matches
Max Line Set Length inc 225ft 1 x MH026 + 1 x MH052, either Neo Forte or Slim Duct
Max Vertical Separation of 98ft 2 x MH052, either Neo Forte or Slim Duct
Max Individual line set length 75ft 3 x MH026, either Neo Forte or Slim Duct
Charged with R410A for 25ft 2 x MH026 + 1 x MH035, either Neo Forte or Slim Duct
Addl R410A charge 3/8" line 0.2oz/ft over 25ft 2 x MH026 + 1 x MH052, either Neo Forte or Slim Duct
Addl R410A charge 1/2" line 0.3 oz/ft of 25ft 2 x MH035 + 1 x MH026, either Neo Forte or Slim Duct
3 x MH035, either Neo Forte or Slim Duct
Certifications 4 x MH026, either Neo Forte or Slim Duct
Safety UL & Ulc
Performance ARI Certified Outdoor Fan
ARI Certification Reference # TBA The outdoor unit fan shall be a propeller type driven
by a single BLDC fan motor for optimum efficiency and
Warranty 5 Years Compressor accurate head pressure control
3 Years Parts
120 Days ltd labor Controls
Control signal shall be a DDC type signal
Options 25 or 50ft Line Sets Controls shall integrate with a BMS system
Condenser Brackets Control wiring shall require 16AWG shielded wire
Operation range : Cooling 23 DegF to 115 DegF
Operation range : Heating 5 DegF to 75 DegF
Quietside 8750 Pioneer Blvd, Santa Fe Springs CA 90670 Tel:562 699 6066, Fax: 562 699 4351
6 Pine Hill Dr, Carlisle PA 17013 Tel : 717 243 2535, Fax : 717 243 7917
www.quietside.com
Due to Samsung's policy of on-going product development specifications are subject to change without notice
SUB-SAMMH080 04-08