Is there any other Supplier in India otherthen following who can supply

420kV, 40 KA for 1 sec. Triple pole , Double Break , motor operated Isolator

1) GR POWER

2) Switchgear & Structurals (Inda) Pvt Ltd.

3) S & S Power

5) HIVELM

6) Siemens

Please help!!

With Regards

Vineet Dhiman

@@@@@@@@@

HORIZONTAL DOUBLE BREAK TYPE


 
ISOLATOR:  (HDB)
   
Double Break Isolators :
Type : DB
 Turn & twist mechanism with self
wiping contacts.
 Fixed & moving blades are made out
off hard drawn electrolytic copper
 Simultaneous operation of three poles
by individual/group with low
operating torque
 Type tested as per IS and IEC.
 Suitable for all typical substation
layouts.
 Structures to suit requirements.
 Motor/Manual operating
mechanisms.

 Terminal connectors of flexible/rigid


suitable for horizontal/vertical take-
off.
 
   
1

Rat
ed
vol kV 12 36 72.5 123 145 245 420
tag
e
upto
2 Rated Current 1250 4000 4000 4000 4000 4000 4000
Amps
3 Rated Short time withstand current kA peak 25 31.5 40 40 40 40 40
4 Rated peak withstand current kV rms 62.5 80 100 100 100 100 100
5 Power frequency withstand voltage - - - - - - - -
- a) To earth kV rms 28 70 140 230 275 460 520
- b) Across isolating distance kV rms 32 80 190 265 315 530 610
Lightning impulse withstand
6 - - - - - - - -
voltage 1.2/ 50  (micro sec.)  
- a) To earth kV peak 75 170 325 550 650 1050 1425
1425
- b) Across isolating distance kV peak 85 195 375 630 750 1200
(+240)
Switching impulse withstand
7 - - - - - - - -
voltage 250/ 2500 (micro sec)
           
  a) To earth kV peak 1050
- - - - - -
            900
  b) Across isolating distance kV peak
- - - - - - (+345)
 

@@@@@@@@@@@@@

- HORIZONTAL CENTRE BREAK TYPE


 
ISOLATOR: (HCB)
   
Centre Break Isolators :
Type : CB
 Self wiping contacts.
 Moving blade arms
are made out off
hard drawn
electrolytic
copper/aluminum
alloy.
 Simultaneous
operation of three
poles by
individual/group
with low operating
torque
 Type tested as per IS
and IEC.
 Suitable for all
typical substation
layouts.
 Structures to suit
requirements.
 Motor/Manual
operating
mechanisms.

 Terminal connectors
of flexible/rigid
suitable for
horizontal/vertical
take-off.
 
   
   
1

R
at
ed
kV 12 36 72.5 123 145 245 420
vo
lta
ge
upto
2 Rated Current 1250 4000 4000 4000 4000 4000 4000
Amps
Rated Short time kA
3 25 31.5 40 40 40 40 40
withstand current peak
Rated peak withstand
4 kV rms 62.5 80 100 100 100 100 100
current
Power frequency
5 - - - - - - - -
withstand voltage
- a) To earth kV rms 28 70 140 230 275 460 520
b) Across isolating
- kV rms 32 80 190 265 315 530 610
distance
Lightning impulse
6 withstand voltage 1.2/ - - - - - - - -
50  (micro sec.)  
kV
- a) To earth 75 170 325 550 650 1050 1425
peak
b) Across isolating kV 1425
- 85 195 375 630 750 1200
distance peak (+240)
Switching impulse
7 withstand voltage 250/ - - - - - - - -
2500 (micro sec)
kV            
  a) To earth 1050
peak - - - - - -
b) Across isolating kV             900
 
distance peak - - - - - - (+345)
 

   ©2007 GRPSL.All rights reserved


 @@@@@@@@@@@@@@@ Designed & Hosted by SNinfotech  
GRPSL will supply Motor operating / Manual operating mechanism boxes for its isolators, 
made of  M.S., S.S., Aluminium, with powder coating / epoxy paint, as per colour shade required
by customers / standards.

GRPSL have test facilities for conducting   IP.55/56 test, inhouse facilities to carryout Load Test,
IP x5 (Water jet) Test & H.V. Test (2 kV Test).

Cubicles are Type tested as per latest IS / IEC at third party test laboratories.

@@@@@@@@@@@@@@@@@@@

11 kV PORCELAIN CLAD
VACUUM CIRCUIT BREAKERS  
(OUTDOOR)
   
Technical specification for 11 KV Porcelain Clad Vacuum Circuit Breakers:
 
Service Outdoor
Type Vacuum Porcelain Clad
(Outdoor)
Rated voltage 11 kV
Rated current 630 / 1250 / 2000 Amps
Nominal (Max. ) Voltage 12 KV
Rated frequency 50 Hz
Basic Insulation level 75 / 95 kV peak
das Lightning impulse: 1.2 micro
sec.
Power frequency withstand voltage 28/35 KV rms for 1 Minute
Rated making capacity 33.2 / 50 / 62.5 kA peak
Rated short time current 12.5 / 20 / 25 kA for 3 sec.
Rated Breaking capacity 12.5 / 20 / 25 kA at 12 kV
Rated Auxiliary control voltage 24 / 110 / 220 V DC
Rated voltage of charging motor 220 / 230 V AC
Rated operating sequence 0-0.3 sec. CO-3 Min-CO
Overall Dimensions:
Height of the breaker (without structure) 2040 mm
Width of the breaker 1200 mm
Breadth of the breaker 500 mm
Total height of the breaker 3040 mm
(Including structure but excluding plinth height
400 mm)
Technical Clearances:
Distance between poles 300 mm (min)
Height of the bushing insulator 200 mm (min)
Creepage distance 300 mm (min)
Height of the live part 3000 mm (min)
 

   ©2007 GRPSL.All rights reserved


Designed & Hosted by SNinfotech  
 @@@@@@@@@@@@@@@@@@@@

  DOUBLE BREAK DISCONNECTORS

 DESIGNATION: DBR

 VOLTAGE: 12kV to 420kV

 CURRENT: Up to 4000A

 INTRODUCTION

The Double Break Disconnector is of simple design of three column centre post rotating
used in outdoor high voltage Sub-stations.  

The Disconnector is designed to operate under severe ICE conditions.

CONSTRUCTIONAL FEATURES 

 BASE ASSEMBLY:

The base frame is made out of a fabricated steel structure designed to withstand all the
external forces like wind load, short circuit force, terminal load and seismic force etc..

The centre rotating post is supported by two nos. ball bearing one at top & one at bottom of
the bearing housing with adequate distance between them to avoid wobbling of
Insulator.         

 CONTACTS :

The main contact is of modern design and has the following salient features 

 Reliable
 Robust in construction

 Good electrical & thermal conductivity

 High long & short time current carrying capacity

 Low contact resistance due to multi-point contact


 Suitable for use at high continuous and short time temperature

The Turn & Twist mechanism with self-wiping, pressure reliving spring-loaded contacts
results low contact resistance and ensures proper current transfer in all conditions.  

The mechanism is supported by stainless steel springs for effective closing and opening and
also ensures self locking in the closed condition.

 DEAD CENTRE MECHANISM

The 420kV Disconnector is equipped with the dead centre mechanism that ensures the
locking of disconnector in both close and open position in case of extreme external forces
such as wind force, short circuit force, seismic force etc.  

 LINKAGES

All transmission hinge points are provided with roller and socket type bearing with friction
free nylon washers to prevent any slackness and consequent lost motion.

The linkages are provided with left hand thread & right hand thread studs to achieve minute
adjustments during alignment of disconnector.

 SPECIFICATIONS

Rated Voltage kV 12   24 36 72.5 123 145 245 420


Rated Current upto A 4000
Short time current upto kA 25 25 31.5 31.5 31.5 40 40 40
Peak withstand current kA 63 63 80 80 80 100 100 100
Lighting Impulse To Earth kV 75 125 170 325 550 650 1050 1425
Withstand
voltage Across kV 85 145 195 375 630 750 1200 1425 + 240
Power frequency To Earth kV 28 50 70 140 230 275 460 520
Withstand Across kV 32 60 80 160 265 315 530 610
voltage (1 min.)
Switching To Earth kV               1050
impulse
withstand voltage Across                 900 +345

 
 

@@@@@@@@@@@@@@@@@

                                                                                                                                                   
CENTRE BREAK DISCONNECTOR 
DESIGNATION: HCB

VOLTAGE: 72.5kV to 420kV

CURRENT: Up to 4000A

INTRODUCTION 

The horizontal Centre Break Disconnector is of simple design of two post rotating Centre
Break contacts used in outdoor high voltage Sub-station.

The Disconnector is designed to operate under severe ICE conditions. 

 CONSTRUCTIONAL FEATURES 

 BASE ASSEMBLY:

The base frame is made out of a fabricated steel structure designed to withstand all the
external forces like wind load,  short circuit force, seismic force, terminal load etc.  

The rotating post is supported by two nos. ball bearing one at top & one at bottom of the
bearing housing with adequate distance between them to avoid wobbling of
Insulator.               

 CONTACTS:

The main contact is of modern design and has the following salient features 

 Reliable
 Robust in construction

 Good electrical & thermal conductivity

 High long & short time current carrying capacity

 Low contact resistance due to multi-point contact

 Suitable for use at high continuous and short time temperature

The jaw and fist type contacts are so designed that the current transfer takes place
through multi-point contacts that are equipped with stainless springs, which ensure low
contact resistance.  
Wiping action carried out during closing & opening of isolator and the design ensures low
operational torque & effective closing of contacts. 

The rotating contacts of 420kV disconnectors transfers the current from the terminal
stud to the moving blade through silver plated bronze ball contacts that are housed in a
bronze housing and pressed against the stud and housing though a stainless steel
spring. The rotating contact construction is completely sealed to ensure maintenance
free. 

 DEAD CENTRE MECHANISM

The 420kV Disconnector is equipped with the dead centre mechanism that ensures the
locking of disconnector in both close and open position in case of extreme external forces
such as wind force, short circuit force, seismic force etc.  

 LINKAGES

All transmission hinge points are provided with roller and socket type bearing with friction
free nylon washers to prevent any slackness and consequent lost motion.

The linkages are provided with left hand thread & right hand thread studs to achieve
minute adjustments during alignment of disconnector.

 SPECIFICATIONS

Rated Voltage kV 12   24 36 72.5 123 145 245 420


Rated Current upto A 4000
Short time current upto kA 25 25 31.5 31.5 31.5 40 40 40
Peak withstand current kA 63 63 80 80 80 100 100 100
Lighting Impulse To Earth kV 75 125 170 325 550 650 1050 1425
Withstand
voltage Across kV 85 145 195 375 630 750 1200 1425 + 240
Power frequency To Earth kV 28 50 70 140 230 275 460 520
Withstand Across kV 32 60 80 160 265 315 530 610
voltage (1 min.)
Switching To Earth kV               1050
impulse
withstand voltage Across                 900 +345

 
 

 @@@@@@@@@@@@@@@

                                                                                                     VERTICAL BREAK


DISCONNECTOR:

DESIGNATION:VB

VOLTAGE:25 kv

CURRENT: Up to 2000A

The vertical break disconnector is of simple design of two post insulator and one operating
rod insulator.

The arm moves vertical position by the operating rod insulator for disconnecting the line.
This design is mostly used in Indian Railways electrification / traction. 

The disconnector is suitable for mounting Horizontally or Vertically as per sub-station


layout. 

CONSTRUCTIONAL FEATURES: 

 BASE FRAME

Base frame is made our of a fabricated steel structure to withstand all the external forces
like wind load, short circuit force     and seismic force etc., 

 CONTACTS

Reverse  loop silver plated copper jaws results good electrical & thermal conductivity.
Current transfer takes place through line contact of fixed contacts supported by stainless
steel  springs, which ensures low contact resistance.

 LINKAGES

All transmission hinge points are provided with roller and socket type bearing with friction
free nylon washers to prevent any slackness and consequent lost motion.

 @@@@@@@@@@@@@@@@
EARTHING SWITCH

DESIGNATION: ES

VOLTAGE: 12kV to 420kV

  The Disconnector may be provided with built on earthing switches on either left hand
side or right hand side or on both side as per customer requirement. Maintenance
earthing switch can also be used for bus bar earthing during maintenance .  

The 420kV-earthing switch has got the following salient features 

      Self locking

During closing the earth switch makes a double movement 

a) The earthing blade rotates through 90 degrees to reach the vertical position i.e.
parallel to the insulator .

b) Subsequently the blade makes a vertical upward movement to the end position to
ensure a proper spring loaded contact.

This design results in the locking of the moving blade in the fixed female contact
preventing any opening due to short circuit, wind & any seismic forces, even if the
operating shaft gets disconnected. 

In order to ensure proper current transfer under all conditions, the earthing switch is
equipped with high pressure silver plated contacts at the bottom, which transfers
currents from moving blade to the base frame/earth. Flexible earth connections are not
required i.e. a maintenance free Earthing switch in its life time. 

A mechanical interlock between the disconnector and the eating switch prevent faulty
operations.

 
@@@@@@@@@@@@@@

  OPERATING MECHANISM:

        These Disconnectors or Earthing switches are offered with following types of

       Operating Mechanisms:

                                        1.Motor operating mechanism

                                        2.Manual with gear mechanism

                                        3.Manual operating mechanism

        1.MOTOR OPERATING MECHANISM

  The motor operating mechanism is provided with double stage reduction gear i.e. spur
gears at first stage and worm gear at second stage to achieve smooth operation and self
locking of the mechanism.

The gear can be operated by three phase AC Induction motors or Permanent Magnet DC
motors as per the customer’s requirement. Suitable thermal overload relays are provided
to protect the motor from overload.  

The control circuits may be DC or AC as per the Customer’s requirement.  

Auxiliary contacts for position indication and interlocking with other equipments are
housed in the operating mechanism. If required make before break (MBB) contacts can
also be fitted with the auxiliary contact as per customer’s requirement. 

In case of individual pole operated disconnectors, the operating mechanism are provided
with one master and two followers. All controls shall be from the master. Pole
discrepancy relays are provided in the master to detect any pole discrepancy.

The following features in the mechanism ensures safety and faultless operation.

 Provision for electrical interlocking with other equipment


 Interlocking between motor and manual operation

 Space heater with thermostat to protect the electrical components

   2. MANUAL WITH GEAR MECHANISM

The manual with gear operating mechanism is provided with worm and worm gear to
achieve smooth operation and self locking of the mechanism.

Auxiliary contacts for position indication and interlocking with other equipments are
housed in the operating mechanism.
   3. MANUAL OPERATING MECHANISM

The manual operating mechanism is provided with a handle to operate the disconnector /
earthing switch. Locking is being provided in both the close and open conditions.

If required electrical interlocking can be provided for interlocking with other equipments.

Auxiliary contacts for position indication and interlocking with other equipments are
housed in the operating mechanism.

  

@@@@@@@@@@@@@@