You are on page 1of 2

W.L.

combination

Refrigerating
C1010/C3010/C4010/C8010 Series
type dryer Filter and regulator lubricator integrated
Desiccant
type dryer Port size: 1/8 to 1
High polymer
membrane JIS symbol
dryer

Air filter

Auto. drain
/ others
F.R.L.
Specifications
(Module unit)
Descriptions C1010 C3010 C4010 C8010
F.R.L.
(Separate)
Compact
F.R.
Precise
regulator
F.R.L.
(Related
products)
Clean
F.R. Appearance
Electro
pneumatic
regulator
Air
booster
Speed
control valve

Silencer

Check valve
/ others
Filter/regulator W1000 W3000 W4000 W8000
Joint Component
/ tube Lubricator L1000 L3000 L4000 L8000
Vacuum
filter
Working fluid Compressed air
Vacuum Max. working pressure MPa 1.0
regulator
Withstanding pressure MPa 1.5
Suction
plate Ambient temperature range 5 to 60
Magnetic Filtration rating m 5
spring buffer
Set pressure range MPa 0.05 to 0.85 (Note 3) 0.05 to 0.85
Mechanical
pressure SW Min. drip flow (Note 1) m3/min (ANR) 0.015 0.03 0.065 0.065
Electronic
pressure SW
Relief With relief mechanism
Contact / close Oil capacity cm3 20 85 170 170 (MA x 360)
contact conf.
SW
Drain capacity cm 3
12 45 80 80 (Note 2)
Air sensor
Applicable oil Turbine oil Class 1 ISO VG32 (spindle oil can not be used)
Pressure SW Port size Rc, NPT, G 1/8, 1/4 (3/8 uses an adapter) 1/4, 3/8 (1/2 uses an adapter) 1/4, 3/8, 1/2 (3/4 uses an adapter) 3/4, 1 (1 1/4 uses an adapter)
for coolant
Small Product weight kg 0.31 0.97 1.45 3.57
flow sensor
Standard accessories Pressure gauge, bracket, bowl guard
Small
Note 1: The minimum drip flow is that at which five drops of turbine oil drip per minute at the set pressure of 0.5 MPa.
flow controller
Flow sensor Note 2: Drainage accumulates up to 170 cm3 only with the manual drain cock.
for air Note 3: The automatic drain's minimum operating pressure for "F" or "FF" with an automatic drain is 0.1 MPa. Initially generated drainage and air are purged until
Flow sensor pressure reaches 0.1 MPa.
for water Note 4: The minimum operation pressure of the automatic drain is 0.15 MPa for the "F1" and "FF1" with an automatic drain.
Total air Note 5: When using C1010 series "F1" with an automatic drain, the minimum operating pressure is 0.2 MPa and maximum operation pressure is 0.7 MPa.
system Refer to the maximum working flow table (page 318) for F1000-F1 with an automatic drain for details on maximum working flow. The working flow must be
Total air less than the maximum working flow.
system
(Gamma) Note 6: When element option "Y" is selected, refer to the maximum working flow table (page 318) for maximum flow. The working flow must be less than the
maximum working flow.
Ending

262 นิวเมติก.com
W.L Combination
How to order
How to order A Model no.
Refrigerating
type dryer
* Refer to page 244 for
C1010 6 C U SV A6

C1010

C3010

C4010

C8010
explanation of an option. Desiccant
type dryer
G Piping adapter set H Pressure gauge option (attached) High polymer
membrane
(Attached) Symbol Descriptions dryer
A Model no. B Port size Air filter
6 1/8
Auto. drain
B Port size 8 1/4 / others
10 3/8 F.R.L.
15 1/2 (Module unit)

20 3/4 *7 F.R.L.
(Separate)
25 1
Compact
C Port thread type Note 1 F.R.
C Port thread type Blank Rc thread Precise
regulator
N NPT thread
F.R.L.
G G thread (Related
products)
D Option Note 2 Clean
D Option F.R.
Blank Filter with manual drain cock, lubricator without manual cock
Electro
C Lubricator with manual cock pneumatic
regulator
Drainage F Filter/auto. drain w/ manual override (NO : Exhaust w/o pressurized)
Air
F1 Filter/auto. drain w/ manual override (NC : No exhaust w/o pressurized) booster
FF Filter/large auto. drain w/ manual override (NO : Exhaust w/ot pressurized) Speed
Note 3 FF1 Filter/large auto. drain w/ manual override (NC : No exhaust w/o pressurized) control valve
Blank Polycarbonate bowl Silencer
Bowl
Z Nylon bowl
material Check valve
M Metal bowl / others
Blank 5 m
Element Joint
Y 0.3 m (submicron) Note 4 / tube
Pressure Blank 0.05 to 0.85MPa Vacuum
filter
range L 0.05 to 0.35MPa
Vacuum
Blank With relief mechanism regulator
Relief
N Nonrelief type Suction
Blank With standard pressure gauge (G401) plate
Pressure
T W/o pressure gauge (gauge port (Rc1/4) is assembled / sealed) Magnetic
gauge spring buffer
T8 Pressure gauge attached (gauge port (Rc1/4) is assembled by open)
Flow Blank Standard flow (left right) Mechanical
pressure SW
direction X1 Reverse flow (right left)
Electronic
E Assembly attachment Pages 368 to 379, 392, 393 pressure SW
E Assembly attachment Contact / close
Blank Without assembly attachment type contact conf.
SW
U Assembly attachment type Note 5
S Pressure switch (P1100, 4100, 8100) Air sensor
P Pressure switch (P4000) Pressure SW
Assembled
V Shut-off valve (V1000, 3000) for coolant
K Lockout valve (V3010) Small
flow sensor
F Display unit Small
F Display
Blank MPa display, Rc thread flow controller
unit
Note on model no. selection J1 MPa display, NPT, G thread Flow sensor
for air
Note 1: When G threads or NPT threads are selected, the IN, OUT, G Piping adapter set (attached) Pages 394 to 396
Flow sensor
gauge port, and drainage discharge port (metal bowl Blank Not attached for water
automatic drain) are the target, as are attachments P and V. A6* 1/8 piping adapter set Total air
Note 2: Select options per drainage, bowl material, element, and A8* 1/4 piping adapter set system
regulator sections. When selecting options for several items, Total air
A10* 3/8 piping adapter set system
list options in order from the top. (Gamma)
Note 3: Refer to page 246 for the automatic drain use conditions. A15* 1/2 piping adapter set
Note 4: Refer to page 318 for maximum processing flow when A20* 3/4 piping adapter set Ending
option "Y" is selected. A25* 1 piping adapter set
Standard Series

Note 5: Assembly attachment installation position A32* 1 1/4 piping adapter set
Symbol Installation position Applicable model *Adaptor screw type
F.R.L. unit

C1010 to C8010 Blank Rc thread


S or P W + (S, P) + L
(Excluding 8000 for "P") N NPT thread
G G thread
V or K W + L + (V, K) C1010 to C4010
H Pressure gauge option (attached) Page 687
Note) Indicate "U" + "S", "P" , "V", and "K" when selecting Blank Not attached
an assembly attachment. G49P G49D-8-P10 (L: G49D-8-P04)
Use the combination custom combination G59P G59D-8-P10 (L: G59D-8-P04)
specifications other than the above. G40P G40D-8-P10 (L: G40D-8-P04)
Note 6: If NPT is selected for the "C" piping thread type, a NPT G50P G50D-8-P10 (L: G50D-8-P04)
pressure gauge is enclosed. If Rc or G thread is selected,
G41P G41D-8-P10 (L: G41D-8-P04)
an R thread pressure gauge is enclosed.
G52P G52D-8-P10 (L: G52D-8-P10)
Note 7: Piping adaptor A400-20 is attached on the both ends of C4010-20.

นิวเมติก.com
263

You might also like