You are on page 1of 3

RENEWABLEENERGIES DLSUNWIND24VandDLSUNWIND12V Hybridsolar/windenergytrainer

DLSUNWIND24V

Description
Themaintargetofahybridpowersystemistocombinemultiplesourcestodelivernonintermittentelectric power,tryingtotakeadvantageofmultipleavailablerenewableenergies. TheTraineriscomposedoftwosubsystems,oneforthegenerationofelectricenergyfromsolarphotovoltaic energythroughasolarpanelandtheotherforthegenerationofelectricenergyfromwindenergythrougha windturbine. Inthistrainer,oneofthetwoinverters,actingasmaster,synchronizesthefrequencyofthesecondinverter, acting as slave, to allow creating a connection between the two outputs that operate as a single line with doubleavailablepower.

CharacteristicsoftheTrainers
TheTrainersarecomposedof: PFS 24Vversion 12Vversion

AEROGEN

DL9012

DL9013M

DL9013S

DL9044

DL9017

DL9018

DL9021

DL9022

DLSIMSUN

DL21001M

85W,12V Photovoltaic module mounted on a support with wheels and 185W,24V complete with graduated scale on one side for adjustment of the inclination and calibrated cell in the upper part for measuringthesolarirradiation. 400W wind turbine, with anemometer and wind direction sensormountedonastand.Thewindturbineisprovidedwitha dcmotorkitinordertousethetrainerinsidetheclassroomor incaseofabsenceofwind. Electronic regulator module for battery charging, with LCD displayforinformationonthestatusofthesubsystem.Itisable to display both solar voltage and battery voltage as well as charging current, AmpHour charge accumulation and temperature. DC/ACconvertermodule,withsinusoidaloutputtogeneratean 1200W 500W electricalnetwork(mains).Withacircuitbreakertoswitchon withtwo withone and off the inverter. It operates as master and it is provided 12Vbatteries 12Vbattery withcontrolpaneltosettheinverterconfigurationandcontrol alsofortheDL9013Smodule. DC/AC converter (or inverter) module. Same characteristics of Sameas Sameas theDL9013Minverter,butoperatingasslave.Theoutputcan above above bedefinedwhenconnectedtoDL9013M. Load module with a 20 W, 12Vdc halogen lamps and a 3W, 4supplied 2supplied 12Vdc LED lamp. Each lamp incorporates an On/OFF control independentswitch. Loadmodulewitha35W,mainshalogenlampanda3W,mains LED lamp. Each lamp incorporates an On/OFF control independentswitch. Variablelogarithmicrheostatmodule,80,6Amax.,toloadthe photovoltaic panel in order to detect the voltagecurrent characteristiccurves. Instrumentsmoduleformeasuringsolarparameters.Itdisplays: voltagesandcurrents,solarirradiance,temperatureofthesolar panel,electricpower. Instruments module for measuring wind parameters. It displays: voltages and currents, wind speed, wind direction, electricpower. Setoflampstolightthephotovoltaicsolarpanelinordertouse 2supplied 1supplied thetrainerinsidetheclassroomorincaseofacloudysky.The intensity of the light can be controlled by the operator locally throughapotentiometerorremotelythroughaDCsignal. Frameforthemodules.

Completewithasetofconnectingcablesandwithanexperimentmanual.

Thefollowingrepresentstheblockdiagramofthesystem. The two inverters operate in masterslave mode to generate a common mains that allows compensating therequestsforenergyfromtheendusers.

Photovoltaic panel

Charge regulator

Inverter (master)

Gene rated Mains

AC loads

Circuit breaker Instruments Battery

DC loads

AC loads

Synchronism

Windturbine

Charge regulator &controller

Inverter (slave)

Circuit breaker Instruments

DCloads

Battery

You might also like