You are on page 1of 52

Highly efficient mini energy pumps with energy label A

Heating Air-conditioning / Refrigeration Service water

Where service still means real services

Birals partners are among the best. Together we do our utmost to offer the final consumer a perfect service. A whole range of services help our partners to achieve their own high quality, economical performance. These services include: Service team Our personnel is on hand to offer fitters help and advice around the clock, seven days a week. Not only is our personnel familiar with our own pumps: our service team members also have expert knowledge of all kinds of different heating systems. They know where problems can occur and the solutions that are available. Delivery service We deliver pumps and spare parts where theyre needed. If necessary immediately, even before the heating system has had time to cool down.

Hotline A team of qualified experts advise fitters and planning engineers whenever they require support. Quickly and without fuss, so that problems can be solved on the spot whenever they arise. Documentation The more complex and varied heating systems become, the more crucial the correct choice and installation of the pumps. Our documentation, catalogues and PC programs considerably simplify these procedures. Training programs For fitters, planning engineers and junior personnel. Topics go far beyond the range and technology of our own pumps. They also include sales issues and general matters of work organization and business management. These services are financed through the price of our pumps, which are slightly higher than those of our competitors. Our successful customers have long known that nowadays there is nothing to be gained financially by purchasing a pump a little more cheaply. By paying just that little bit more, you can save time, avoid irritation, and prevent malfunctions. And thats what our services are there for.

Services: success for Biral partners


Repairs and spare-parts service 24-hour service

Delivery service Training and instruction


Documentation and layout aids

Advice Product structure according to application situation Outstanding pumps Swiss quality Product range Consulting services Long-term follow-up and support
Earnings potential

Introduction
Page 2 3 4 6 10 Biral innovator of energy label A technology Quality features of Biral heating circulating pumps The right pump at the right place Notes for project planning and installation Standards and obligations Old circulation pumps are true energy guzzlers Schedule for eco-design guidelines

Heating circulation pumps You enjoy your cosy warm home. And the Mini-Energy pump from Biral allows the heating water to circulate. Silently and with maximum efficiency!

Page 11 23

Single pumps Twin pumps

Cold water circulation pumps 31C outside temperature. The air-conditioning in the office ensures a comfortable working atmosphere. And the Mini-Energy cold water pump from Biral plays its part. With maximum efficiency.
Page 25 37 Single pumps Twin pumps

Intelligent service water pumps You turn on the shower as usual. And the AXW-smart from Biral already knows. Thanks to smart-technology!

Page 39

AXW smart

Service water pumps Seepark Hotel, Thoune. The man in suite 57 turns on the shower. And Biral AXW is on the spot with maximum efficiency.

Page 43

AXW, AW

Service water

Service water

Air-conditioning/ Refrigeration

Heating

Biral innovator of energy label A technology

A
T TES ON d ct PS oo du UM yg pro GP Ver wiss A 12-1 TIN ch e S type ipp. HEA Th w.kt
al Bir
ww 3 90 4 25 : 04 rvice o-Se Ab 17 266 044 ion: dakt Re r tobe 3. Ok 16 Nr. 2007 17 90

promoted by the Wuppertal Institute for Climate, Environment, Energy Co.

) 1,5 D( OO YG s t: VER On tegs pump n


eati 9h

007 9/2

Biral with EU energy label A One of the most effective methods countries can use to reduce the increasingly alarming pollution of the environment is to help make consumers aware of the consequences of their actions and indicate ways in which they can act more responsibly. If, in addition, costs simultaneously and increasingly punish negligent behaviour, as in the case of energy, there is added incentive to take remedial action. Electrical appliances, to which pumps also belong, are designated throughout Europe with standard labels. Coloured arrows indicate the energy efficiency of the appliance. This is subdivided into seven so-called energy classes: a class A appliance is particularly economical, while units of class G consume a great deal of energy. In this way the consumer can assess at a glance the energy efficiency of a unit.

Biral mini-energy pumps since 2000 As long ago as November 2000, Biral won the Wuppertal energy and environment prize, in addition to the Swiss Prix Eta Plus. This was achieved with the heating circulating pump MC 10, the efficiency of which exceeded all previous values.

AXW smart the intelligent Mini-Energy service water pump The world innovation AXW smart was distinguished with the VSK award at the VSK trade-fair in Utrecht. The jury congratulated Biral on this new product. The self-taught pump ensures maximum comfort with massive energy savings. The smart technology learns your consumption habits and provides hot water at the right time.

Biral Pioneers in power-saving heating circulation pumps The Product Test foundation tested nine heating pumps. The test criteria were energyefficiency, handling and suitable design for recycling. The Biral pump is highly economical and received the distinction very good!

Biral was already a leader at that time with regard to efficiency and has gradually enhanced its superiority. In the meantime of course heating systems of all sizes can be fitted with pumps bearing the A-label for maximum energy efficiency: for the sake of the environment and for greater operating reliability to save energy costs.

Quality features of Biral heating circulating pumps


Three main demands are made of our circulating pump: silent operation years of reliable use low energy consumption In order to satisfy these requirements in an increasingly better manner, Biral pumps have been continuously further developed for decades. Manufacture takes place in a modern plant in Mnsingen using the best and fully-proven materials. All circulating pumps are based on fully-proven mechanical components optimised over many years: The indestructible precision sliding bearings ensure silent operation and largely determine the long service life of the pump The high temperature resistance of the winding ensures a long service life. It permits use with high temperature media. The ingenious water supply to the rotor space ensures immediate lubrication of the bearings and even makes venting unnecessary when commissioning small pumps. The new A-series provides significant energy savings. The new motor technology permits energy savings up to 60 percent! Automatic pressure regulation with variable rate of flow ensures a further saving User-friendly operation permits simple adjustment to the required operating conditions The watts indicator shows the end user the current power consumption directly on the pump Various auxiliary modules permit integration of the pump in domestic control systems

The right pump at the right place


It is a fundamental Biral principle to offer exactly the right pump to suit every application.

Field of application

1- or 2-family home

Multiple dwelling Hospital Hotel Administration

A
Mini-Energy pumps Standard pumps Mini-Energy pumps

Radiator and floor heating Single pumps Heating

AX 12 13

MX 10 13 LX 321 323

A 12 A 401 A 402 V2 A 801 V2 A 802 A 1002

Twin pumps

Heating

AD 401 AD 402 V2 AD 652 V2 AD 802

Service water circulation Service water

Air-conditioning/ Refrigeration

Airconditioning/ cooling applications Geothermal Heat pump

A 12 KW A 401 KW

MX 10 13 LX 321 323

A 402 V2 KW A 801 V2 KW A 802 KW A 1002 KW

AXW 12 13 AXW 10 14 smart

WX 10 13

AXW 13 AW 15 AW 401 AW 402 V2 AXW 13 smart, 14 smart

Industry Commercial premises Office buildings

A
Standard pumps Mini-Energy pumps Standard pumps

M 14 15 LX 325 L 1004

A 12 A 401 A 402 V2 A 801 V2 A 802 A 1002

HX 301 802

MD 14 15 LXD 325 LD 1004

AD 401 AD 402 V2 AD 652 V2 AD 802

HXD 301 802

M 14 15 LX 325 L 1004

A 402 V2 KW A 801 V2 KW A 802 KW A 1002 KW

HX 301 802

WX 13 14 W 313 315 W 401 403

AXW 13 AW 15 AW 401 AW 402 V2 AXW 13 smart, 14 smart

WX 13 14 W 313 315 W 401 403

Notes for project planning and installation


1. Selection of circulating pump 2. Required operating pressure at circulating pump

Recommendation for regulated circulating pumps Regulated circulating pumps continually adjust the flowrate along a pre-defined characteristic with changing pipe characteristics.

Nevertheless it is also worthwhile here to make a careful choice of the right pump size.

If the operating pressure is too low, adequate lubrication of the pump sliding bearings (water lubrication) is not ensured and therefore their service life is reduced. The values specified should therefore be observed without fail. The required operating pressure depends on the type of pump, the maximum temperature of the medium and the static pressure. If the position of the expansion vessel is not ideal, the operating pressure at the pump inlet when operating the pump can be reduced further (see fig. 2).

This can lead to penetration of air and inadequate bearing lubrication. In this case the static operating pressure must be raised accordingly.

H E

Fig.: Choice of regulated pumps A = Optimum control range Range with the best degree of overall effectiveness B = Limited control range If possible select a smaller pump C = Limited control range The pump works but has limited control D = Outside the control range If possible avoid

Fig. 2: Pressure distribution = Overpressure range = Underpressure range E = Expansion vessel N = Neutral point H = Delivery head of pump

3. Requirements of medium

4. Pipeline connection and pump installation Anti-frost mixture Water/glycol mixture with up to 50% glycol is permitted. From 10% glycol proportion the delivery data of the pumps must be corrected according to fig. 3. Example H mixture = 30 kPa Q mixture = 7 m3/h Medium: 50% glycol mixture at 10 C operating temperature Factors according to fig. 4: Fh = 1,26 Fq = 1,57 Conversion of required pump operating point for water heat transfer H water = H mixture Fh = 30 1,26 = 37,8 kPa Q water = Q mixture Fq = 71,57 = 11 m3/h Circulating pump complying with operating point Q water / H water: Biral A 402 V2 Always fit pump between two shut-off devices Fit pump so that the motor shaft is horizontal, regardless of the position of the pump casing (fig. 4) The arrow on the pump casing shows the flow direction (fig. 5) Fit pump in pipeline free from stress When the pump is fitted do not work too closely with a welding flame The fitting of heating pumps on the inlet side reduces the danger of contamination. They should preferably be fitted on the return side if the temperature of the medium is very high.

Water treatment The guidelines of SWKI 97-1 and VDI 2035 Water treatment for heating, steam and air-conditioning systems should be observed. Overall hardness 7 to 14 fH (4-8 dH) pH value 8.3 to 9.5 (8.3 to max. 9 for systems with aluminium or non-ferrous metal components) Oxygen <0,1 mg/dm3 The systems must be thoroughly flushed before filling.

Fh: correction factor for delivery head

Fq: correction factor for flowrate

961083_00

Operating temperature C Fig. 3: Correction factors for pump characteristic compared with water delivery Fig. 4: Fitting pump

961082_00

Fig. 5: Flow direction

5. Settings on regulated circulating pumps

The regulated pumps can be operated in three different modes: Regulation with proportional operating pressure (PP) The internal regulation increases the differential pressure of the system with increasing flowrates. This desired regulation curve can be preset. This regulation is particularly suitable for the following systems: Two-pipe heating systems with thermostatic valves and long pipe sections valves with wide working range high pressure losses Floor heating systems with thermostatic valves and high pressure losses Systems with primary circuit pumps with high pressure loss. Regulation with constant operating pressure (CP) The internal regulation keeps the differential pressure of the system constant if the flowrate changes. This pressure can be preset. This regulation is particularly suitable for the following systems: Two-pipe systems with thermostatic valves and delivery head less than 2 m natural circulation (low pressure loss, large pipe dimensions) Floor heating systems with thermostatic valves Single-pipe heating systems with thermostatic valves and regulating valves Systems with primary circuit pumps with low pressure loss Regulation with constant speed (CS) With this form of regulation the internal pressure regulation is switched off. The speed of the pump can be adjusted to a constant value manually or by an external signal (auxiliary module 0 10 V). This form of regulation is particularly suitable for systems with constant pressure conditions (heat exchangers, boiler feed pumps, etc.) or for external system regulation.

Choice of regulation characteristic With changing pipeline resistance (K 1 K 2) regulated circulating pumps continuously adjust the flowrate along a pre-defined characteristic curve (fig. 6). The required regulation characteristic can be set by means of the rotary switch or key A2 (fig. 8).

Fig. 6: Continuous variation of pump speed in regulated pumps

Power limiting All regulated circulating pumps are supplied with preset power limiting. This characteristic curve is sufficient owing to the power reserve in the design. The limiting also saves energy and flow noise is reduced owing to over-dimensioned pumps. If full power is required, the pump can be changed over in the terminal box (see operating instructions).

Fig. 7: Power limiting for electrically regulated pumps Power limiting

Operation Regulated circulating pumps can be operated in three different regulation modes and in part have a so-called automatic minimum speed.

LED 1

A1: A2:

A2
LED 2

A3:

Form of regulation Regulation characteristics 15 6 max. pump characteristic Illuminated symbol for fault, ext. operation Proportional pressure Constant pressure Constant speed

A1

A3

Fig. 8: Setting regulation characteristic curves

Aut.

with and without automatic minimum speed

LED 1: Indication of regulation characteristic set LED 2: Indication of current rate . of flow V (25 100%)

Standards and obligations


Eco-design guidelines Commission regulation (EC) No 641/2009 of 22 July 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for glandless standalone circulators and glandless circulators integrated in products. The preparatory study shows that approximately 14 million circulators are placed on the Community market annually and that their most significant environmental impact out of all life-cycle phases is the use phase energy consumption amounting to 50 TWh in 2005, corresponding to 23 million tonnes of CO2 emissions. If no specific measures are taken, electricity consumption is predicted to increase to 55 TWh by 2020. The preparatory study shows that use phase electricity consumption can be significantly improved. This Regulation should quickly ensure the placing on the market of technologies that reduce the life-cycle environmental impact of circulators, leading to estimated electricity savings of 23 TWh by 2020, corresponding to 11 Mt of CO2 equivalent, compared with the situation, where no action is taken.

Old circulation pumps are true energy guzzlers


Electricity use per year in a detached house
Electric cooker Heating pump (standard) Tumble dryer Washing machine Freezer Fridge Dishwasher Oven TV set High-efficiency pump kWh/a 200 400 600 800 1000

Schedule for eco-design guidelines


01. 01. 2013 01. 08. 2015
EEI >0.27

From 1 January 2013, the energy efficiency index (EEI) of external wet rotor circulation pumps must not exceed a value of 0.27.
st

From 1st August 2015, the energy efficiency index (EEI) of external wet rotor circulation pumps, and wet rotor pumps integrated into products, must not exceed a value of 0.23. In April 2010, Biral removed traditionally controlled circulation pumps from its range and is already focused on the new energy-efficient technology, for heating as well as coldwater pumps. Biral is therefore already making a vital contribution to CO2 reduction.

EEI >0.23

Drinking water circulation pumps do not come under the eco-design guidelines. Nevertheless, Biral is already introducing high-efficiency energy-saving pumps into its range for this category.

10

Heating circulation pumps


AX 12 AX 13 A 12 A 401, A 500 A 402 V2 A 801 V2 A 802 A 1002
List of models DN Installation dimension 2170 mm 2180 mm 11/2180 mm 11/2130 mm 1130 mm 2170 mm 2180 mm 11/2180 mm 40220 mm 40250 mm 50220 mm 40220 mm 40250 mm 50270 mm 65270 mm 65340 mm 80360 mm 80360 mm 100450 mm Type AX 12, AX 13 A X 12-2, AX 13-2 AX 12-1, AX 13-1 AX 12-3, AX 13-3 AX 12-4, AX 13-4 A 12, A 13, A 14, A 15 A 12-2, A 13-2, A 14-2, A 15-2, A 16-2 A 12-1, A 13-1, A 14-1, A 15-1, A 16-1 A 401 A 401-1 A 500 A 402 V2 A 402-1 V2 A 501 V2, A 502 V2 A 651-1 V2 A 651 V2, A 652 V2 A 801 V2 A 802 A 1002 Perm. operating pressure PN 10 PN 10 PN 10 PN 10 PN 10 PN 10 PN 10 PN 10 PN 6/10 PN 6/10 PN 6-10 PN 6-16 PN 6-16 PN 6-16 PN 6-16 PN 6-16 PN 6 G/PN 16 PN 6 G/PN 10 PN 6 G/PN 10 Energy class A A A A A A A A A A A A A A A A A A A

40 50 40 50 65 80 80 100 G Standard design Special design

11

Heating

Standard

AX 12, AX 13 5 45 W

A 12 A 401, A 500 8 174 W

A 402 V2 A 801 V2 25 930 W

A 802 A 1002 501790 W

Fault or operating message (switchable)

Fault reporting

  

External speed, 0 10 V

External minimum speed

Thermal insulation shells

1)

Power limiting (can be deactivated) Automatic night reduction (can be activated)

 

961192_00

Connection Pump diagram L = Lead


N = Neutral line = PE wire, protective conductor

N L

N L

L N

Supply 1 230 V Back-up fuse 10 A

Supply 1 230 V Back-up fuse 10 A

Supply 1 230 V Back-up fuse 10 A

Supply 1 230 V Back-up fuse 10 A

51-54 fault or operating message (switchable) as NO contact: closes for fault/operation Contact loading max. 250 V~, 1 A 51-52 fault or operating message (switchable) as NC contact: opens for fault/operation Contact loading max. 250 V~, 1 A 7-8 Alarm external fault reporting Max. load: 250 V AC, 5 A

Alarm

54 52 51
max. 250 V 1A

54 52 51
max. 250 V 1A

7 8
max. 250 V 5A

1-2 External ON/OFF Control contact for switching the pump on and off externally 3-4 MIN Min. characteristic line 5-6 analogue input 0 10 V 5 = +10 V 6= 0V

Start/Stop Min

0-10V

+ -

1 2 3 4 5 6

12

1) Pumps AX 12,-1 -2, AX 13 -1,-2 are fitted as standard with a thermal insulation shell

Options

AX 12, AX 13 5 45 W

A 12 A 401, A 500 8 174 W

A 402 V2 A 801 V2 25 930 W

A 802 A 1002 501790 W

Signal module Operating message External ON/OFF External minimum speed Twin pumps function Not possible in combination with control module Control module External speed 0 10 V / 0 20 mA External ON/OFF PWM Multitherm interface Twin pumps function Not possible in combination with signal module Thermal insulation shells

 

Construction set for offset electronics installation Media temperature: up to 110 C

Connection Signal module diagram 10-11 control contact for switching


pump on and off externally 10-13 control contact for switching minimum speed on and off externally 61-64 operating or ready message (NO contact) 61-62 operating or ready message (NC contact) 91-92 twin pump

961178_00

13 11 10 91 92

64 62 61

Control module 10-11 control contact for switching pump on and off externally 81-82 Multitherm/PWM interface 71-72 analogue input 010 V or 020 mA for external speed setting 91-92 twin pump
961177_00

81 82 71 72 11 10 91 92

13

Heating

AX 12, -1, -2, -3, -4


Installation length Permissible operating pressure Permissible operating temp. Required operating pressure at at 75C water temperature at 90C water temperature at 110C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min 130/170/180 mm 10 bar +15C to +110C 500 m a.s.l. 0.05 bar 0.30 bar 1.10 bar 0.01 bar 2.3 kg 1230 V, 50 Hz 0.050.19 A 0.05 A 522 W 5W
140

124 78 29

158.4 129.4

AX 12 = 11/2,11/4,1,3/4 D = 2 L = 170 mm H = 235 mm AX 12-2 = 11/2,11/4,1,3/4 max.10 D = 2 L = 180 mm H = 245 mm

AX 12-1 = 1,3/4 D = 11/2 L = 180 mm H = 235 mm AX 12-3 = 1,3/4 D = 11/2 L = 130 mm H = 185 mm AX 12-4 = 1/2 D = 1 L = 130 mm H = 178 mm

961156_00

D
50.2

140

H [kPa]
ma x

H [m]

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 110 30 30 110 35 35 90 40 40 70 The pump is fitted with internal electric motor protection and requires no external motor protection. The pumps AX 12,-1,-2 are fitted with a thermal insulation shell.

min

P [W] 1

max

min
961056_02

AX 13, -1, -2, -3, -4


Installation length Permissible operating pressure Permissible operating temp. Required operating pressure at at 75C water temperature at 90C water temperature at 110C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min 130/170/180 mm 10 bar +15C to +110C 500 m a.s.l. 0.05 bar 0.30 bar 1.10 bar 0.01 bar 2.3 kg 1230 V, 50 Hz 0.050.38 A 0.05 A 545 W 5W
140

124 78 29

158.4 129.4

AX 13 = 11/2,11/4,1,3/4 D = 2 L = 170 mm H = 235 mm AX 13-2 = 11/2,11/4,1,3/4 max.10 D = 2 L = 180 mm H = 245 mm

AX 13-1 = 1,3/4 D = 11/2 L = 180 mm H = 235 mm AX 13-3 = 1,3/4 D = 11/2 L = 130 mm H = 185 mm AX 13-4 = 1/2 D = 1 L = 130 mm H = 178 mm

961156_00

D
50.2

140

0 20 ft 16 12 8 4 0 H0 [kPa] 50 40 30 20 10 0 60 P [W] 1 40 20 0 0 0

v(1") 0.5 0.2 0.4

1 0.6

1.5 0.8 1.0

2 1.2

m/s

2.5 l/s 1.6 H [m] 5 4 3 2

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 110 30 30 110 35 35 90 40 40 70 The pump is fitted with internal electric motor protection and requires no external motor protection. The pumps AX 13,-1,-2 are fitted with a thermal insulation shell.

ma

min
0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 m/h 6

1 0

max

min 2 4 6 8 10 12 14

961057_01

imp.g.p.m 20

14

A 12, -1, -2
92

188 49

201 152

Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min

170/180 mm 10 bar +15C to +110C 2) max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.25 A 0.14 A 833 W 819 W

A 12 = 11/2,11/4,1,3/4 D = 2 L = 170 mm H = 235 mm

137

max. 10
960947_00

A 12-1 = 1,3/4 D = 11/2 L = 180 mm H = 235 mm

A 12-2 = 11/2,11/4,1,3/4 D = 2 L = 180 mm H = 245 mm

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90 40 40 70 2) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module See page 48 for further details
1) As delivered with power limiting

A 13, -1, -2
92

188 49

201 152

Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min

170/180 mm 10 bar +15C to +110C 2) max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.35 A 0.14 A 850 W 819 W

A 13 = 11/2,11/4,1,3/4 D = 2 L = 170 mm H = 235 mm

137

max. 10
960947_00

A 13-1 = 1,3/4 D = 11/2 L = 180 mm H = 235 mm

A 13-2 = 11/2,11/4,1,3/4 D = 2 L = 180 mm H = 245 mm

0 20 ft 16 12 30 8 4 0 20 10 0 0 60 P [W] 1 40 20 0 0 H0 [kPa] 50

v(1") 0.5 0.2 0.4

1 0.6

1.5 0.8 1.0

2 1.2

m/s 2.5 l/s 1.6 H [m] 5 4

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90 40 40 70 2) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module See page 48 for further details

1) 40 5

5 4

6m ax
3

4 3 2 1

3
2 1

2 1 0 4.5 5 m/h 6

min
0.5 1 1.5 2 2.5 3 3.5 4

6 max

1
min
960990_02

10

12

14

imp.g.p.m 20

1) As delivered with power limiting

15

Heating

A 14, -1, -2
92

188 49

201 152

Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min

170/180 mm 10 bar +15C to +110C 2) max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.5 A 0.14 A 870 W 819 W

A 14 = 11/2,11/4,1,3/4 D = 2 L = 170 mm H = 235 mm

137

max. 10
960947_00

A 14-1 = 1,3/4 D = 11/2 L = 180 mm H = 235 mm

A 14-2 = 11/2,11/4,1,3/4 D = 2 L = 180 mm H = 245 mm

0 H [kPa] 60 50 40 30 8 4 0 20 10 0 0 70 P1 [W] 40 20 0 0 5 4 0

v(1") 0.4

1.5 0.8

2 1.2

2.5 1.6

m/s

3.5 2 l/s

4 2.4 H [m] 6 5 4

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90 40 40 70 2) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module See page 48 for further details

20 ft 16 12

1)

6m ax 4
3

3
2 1

3 2 1 1
6 max

2 1 0 7 m/h 9

min
2 3 4 5 6

1
min
960955_02

12

15

18

21 imp.g.p.m

30

1) As delivered with power limiting

A 15, -1, -2
92

188 49

201 152

Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min

170/180 mm 10 bar +15C to +110C 2) max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.8 A 0.25 A 8107 W 819 W

A 15 = 11/2,11/4,1,3/4 D = 2 L = 170 mm H = 235 mm

137

max. 10
960947_00

A 15-1 = 1,3/4 D = 11/2 L = 180 mm H = 235 mm

A 15-2 = 11/2,11/4,1,3/4 D = 2 L = 180 mm H = 245 mm

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90 40 40 70 2) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module See page 48 for further details

5 4 3

2 1

1) As delivered with power limiting

16

A 16-1, A 16-2
92

188 49

201 152

Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min

180 mm 10 bar +15C to +110C 2) max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.8 A 0.25 A 8107 W 819 W

A 16-1 = 1,3/4 D = 11/2 L = 180 mm H = 235 mm

137

max. 10
960947_00

A 16-2 = 11/2,11/4,1,3/4 D = 2 L = 180 mm H = 245 mm

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90 40 40 70 2) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module See page 48 for further details

6m ax

150

2
960948_01

1) As delivered with power limiting

A 401, A 401-1
92

188

224 204 40 149 110 100

Installation length A 401 A 401-1 Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min

220 mm 250 mm 10 bar +15C to +110C 2) max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 9 kg 1230 V, 50 Hz 0.11.25 A 0.14 A 8174 W 819 W

A 401 L = 220 mm A = 110 mm


14

18 88

A 401-1 L = 250 mm A = 125 mm

max. 10
960989_00

137

150

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90 40 40 70 2) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module See page 48 for further details

6m ax

150

2
960948_01

1) As delivered with power limiting

17

Heating

A 500
92

188 230.9 50 57 148.4 125 110

Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min

220 mm 10 bar +15C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 1230 V, 50 Hz 0.11.25 A 0.14 A 8174 W 819 W

14 220 137 18 102 max. 10


961398_00

110

165

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90/110 2) 40 40 70/110 2) The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module 2) construction set for offset electronics installation See page 48 for further details

6m ax

150

2
960948_01

1) As delivered with power limiting

18

A 402 V2, A 402-1 V2


Installation length A 402 V2 A 402-1 V2 Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min 220 mm 250 mm 6 16 bar +15C to +95C max. 40C 500 m a.s.l. 0.40 bar 0.85 bar 0.01 bar 14.5 kg 1230 V, 50 Hz 0.252 A 33 A 25420 W 3065 W

354 279 61

B1 40 1/4"

PN 6-16 110 100

A 402 V2 L = 220 mm A = 110 mm B1 = 151 mm B2 = 84 mm


14 18

961180_00

88 B2 160 150

M20x1.5

M16x15

A 402-1 V2 L = 250 mm A = 125 mm B1 = 171 mm B2 = 94 mm

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90/110 2) 40 40 70/110 2) The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module 2) construction set for offset electronics installation See page 48 for further details

1) As delivered with power limiting

A 501 V2
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min 270 mm 6 16 bar +15C to +95C max. 40C 500 m a.s.l. 0.20 bar 0.65 bar 0.01 bar 18.5 kg 1230 V, 50 Hz 0.251.3 A 0.4 A 35275 W 365 W

366 284 76

190 50 1/4"

PN 6-16 125 110

270

14 18 102

961181_00

135

M20x1.5

M16x15

107

160

165

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90/110 2) 40 40 70/110 2) The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module 2) construction set for offset electronics installation See page 48 for further details
1) As delivered with power limiting

19

Heating

A 502 V2
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min 270 mm 6 16 bar +15C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.65 bar 0.01 bar 19 kg 1230 V, 50 Hz 0.453.4 A 1A 70720 W 70200 W

366 284 76

190 50 1/4"

PN 6-16 125 110

270

14 18 102

961181_00

135

M20x1.5

M16x15

107

160

165

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90/110 2) 40 40 70/110 2) The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module 2) construction set for offset electronics installation See page 48 for further details
1) As delivered with power limiting

A 651 V2, A 651-1 V2


Installation length A 651 V2 A 651-1 V2 Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min 340 mm 270 mm 6 16 bar +15C to +95C max. 40C 500 m a.s.l. 0.35 bar 1.45 bar 0.01 bar 22 kg 1230 V, 50 Hz 1.22.4 A 0.7 A 50515 W 50145 W

T1 289 T2

B1 65 1/4"

PN 6-16 145 130

A 651 V2 L = 340 mm A = 170 mm B1 = 207 mm B2 = 119 mm 14 T1 = 381 mm 18 T2 = 81 mm

A 651-1 V2 L = 270 mm A = 135 mm B1 = 179 mm B2 = 98 mm T1 = 391 mm T2 = 73 mm

122 M20x1.5 M16x15


961182_01

B2

160

185

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90/110 2) 40 40 70/110 2) The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module 2) construction set for offset electronics installation See page 48 for further details

1) As delivered with power limiting

20

A 652 V2
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min 340 mm 6 16 bar +15C to +95C max. 40C 500 m a.s.l. 0.35 bar 1.45 bar 0.01 bar 23 kg 1230 V, 50 Hz 0.484.3 A 1A 70930 W 70220 W

381 289 81

207 65 1/4"

PN 6-16 145 130

340

14 18 122

M20x1.5

M16x15 961182_00

170

119

160

185

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90/110 2) 40 40 70/110 2) The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module 2) construction set for offset electronics installation See page 48 for further details
1) As delivered with power limiting

A 801 V2
Installation length Permissible operating pressure Special design Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min 360 mm 6 bar 16 bar +15C to +95C max. 40C 500 m a.s.l. 0.35 bar 1.45 bar 0.01 bar 25 kg 1230 V, 50 Hz 0.484.3 A 1A 70930 W 70220 W

417 319 62 180

193 80 1/4"

PN 6 150 18

PN 16 160 18

180

360

128 M20x1.5 M16x15


961392_00

128 200

107

160

200

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90/110 2) 40 40 70/110 2) The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module 2) construction set for offset electronics installation See page 48 for further details

1) As delivered with power limiting

21

Heating

A 802
Installation length Permissible operating pressure Special design Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature at 110C water temperature For every 100 m altitude Weight Voltage Current Regulation Power Regulation 360 mm 6 bar 10 bar +15C to +95C max. 40C 500 m a.s.l. 0.6 bar 1.0 bar 1.7 bar 0.01 bar 32 kg 1230 V, 50 Hz 0.59.3 A 501790 W

132

100 80 97

506 409

PN 6 160 150

PN 10 160 18

360

250

961333_00

128 200

18

128 200

196

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 1) 30 30 95/110 1) 35 35 90/110 1) 40 40 70/110 1) 1) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell See page 48 for further details
1) As delivered with power limiting

A 1002
Installation length Permissible operating pressure Special design Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature at 110C water temperature For every 100 m altitude Weight Voltage Current Regulation Power Regulation 450 mm 6 bar 10 bar +15C to +95C max. 40C 500 m a.s.l. 0.6 bar 1.0 bar 1.7 bar 0.01 bar 32 kg 1230 V, 50 Hz 0.59.3 A 501790 W

135

100 100 120

530 410

PN 6 170 18

PN 10 180 18

450

250

961347_00

160 220

160 220

196

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 1) 30 30 95/110 1) 35 35 90/110 1) 40 40 70/110 1) 1) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell See page 48 for further details
1) As delivered with power limiting

22

Twin pumps
AD 401 AD 402 V2 652 V2 AD 802

List of models

DN 40

Installation dimensions 40220 mm 40250 mm 50270 mm 65340 mm 80360 mm

Type AD 401 AD 402-1 V2 AD 501 V2, AD 502 V2 AD 651 V2, AD 652 V2 AD 802

Perm. operating pressure PN 6/10 PN 6-16 PN 6-16 PN 6-16 PN 6 G/PN 10

Energy class A A A A A

50 65 80

G Standard design Special design

23

Heating

AD 401
AD 401 A 401 The pumps are designed for individual operation in systems with higher safety requirements (P1 or P2) Parallel operation (P1 + P2) only permitted in constant speed mode (cs) or with external speed setting (0 10 V/0 20 mA) but not in controlled operation mode (cp or pp) Optional: Construction set for offset electronics installation (2 ) Control module (2 ) Signal module (2 ) Both module types with integral twin pump function 22h / 2h alternating operation

AD 401
218 297 50 156 PN 6-10 110 100

220

14 18

961174_00

88 150

AD 402 V2 AD 652 V2
B1 T2

T1 T3 M

PN 6-16 k2 k1

AD 402-1 V2 AD 501 V2 AD 502 V2 AD 651 V2 AD 652 V2

A 402-1 V2 A 501 V2
L1

A 502 V2 A 652 V2
L2 L3

14 18 DN
961213_00

A 651 V2

The pumps are designed for individual operation in systems with higher safety requirements (P1 or P2) Parallel operation (P1 + P2) only permitted in constant speed mode (cs) or with external speed setting (0 10 V/0 20 mA) but not in controlled operation mode (cp or pp) Optional: Construction set for offset electronics installation (2 ) Control module (2 ) Signal module (2 ) Both module types with integral twin pump function 22h / 2h alternating operation

B2

B3

B4

B2

AD 402-1 V2 PN 6-16 DN L1 B1 B2 B3 B4 D k1 (PN 6) k2 (PN 10/16) L2 L3 T1 T2 T3 M 40 250 500 160 72 108 150 100 110 112 144 342 73 267 M 20 1.5 M 16 1.5 kg 30

AD 501 V2 PN 6-16 50 270 578 162 132 123 165 110 125 115 124 349 83 266 M 20 1.5 M 16 1.5 45

AD 502 V2 PN 6-16 50 270 578 162 132 123 165 110 125 115 124 349 83 266 M 20 1.5 M 16 1.5 45

AD 651 V2 PN 6-16 65 340 588 162 130 135 185 130 145 152 158 370 93 269 M 20 1.5 M 16 1.5 55

AD 652 V2 PN 6-16 65 340 588 162 130 135 185 130 145 152 158 370 93 269 M 20 1.5 M 16 1.5 55

AD 802
479 497 97 400

AD 802

A 802

80

PN 6 150 18

PN 10 160 18

360

160

Alternating operation, 24h/24h See page 48 for further details Refer to individual pump for technical data

250

The pumps are designed for individual operation in systems with higher safety requirements (P1 or P2)

128
961334_00

128 200

121

120

120

118

200

24

Cold water circulation pumps


A 12 KW A 401 KW A 402 V2 KW A 652 V2 KW A 802 KW A 1002 KW

List of models

DN

Installation dimension 2170 mm 2180 mm 11/2180 mm

Type A 12 KW, A 13 KW A 14 KW, A 15 KW A 12-2 KW, A 13-2 KW, A 14-2 KW A 15-2 KW, A 16-2 KW A 12-1 KW, A 13-1 KW, A 14-1 KW A 15-1 KW, A 16-1 KW A 401 KW A 401-1 KW A 500 KW A 402 V2 KW A 402-1 V2 KW A 501 V2 KW, A 502 V2 KW A 651-1 V2 KW A 651 V2 KW, A 652 V2 KW A 801 V2 KW A 802 KW A 1002 KW

40 50 40 50 65 80 80 100 G Standard design Special design

40220 mm 40250 mm 50220 mm 40220 mm 40250 mm 50270 mm 65270 mm 65340 mm 80360 mm 80360 mm 100450 mm

Perm. operating pressure PN 10 PN 10 PN 10 PN 10 PN 10 PN 10 PN 6/10 PN 6/10 PN 6/10 PN 6-16 PN 6-16 PN 6-16 PN 6-16 PN 6-16 PN 6 G/PN 16 PN 6 G/PN 10 PN 6 G/PN 10

Energy class A A A A A A A A A A A A A A A A A

25

Air-conditioning/ Refrigeration

KW = modified version for cold water application. With special coating resistant to condensed water.

Standard

A 12 KW A 401 KW, A 500 KW 8 174 W Fault or operating message (switchable)

A 402 V2 KW A 801 V2 KW 25 930 W

A 802 KW A 1002 KW 50 1790 W

Fault reporting

  

External speed, 0 10 V

External minimum speed

Power limiting (can be activated) Automatic night reduction (can be activated) Media temperature: up to 10 C

  

961192_00

Connection Pump diagram L = Lead


N = Neutral line = PE wire, protective conductor

N L

L N

Supply 1 230 V Back-up fuse 10 A

Supply 1 230 V Back-up fuse 10 A

Supply 1 230 V Back-up fuse 10 A

51-54 fault or operating message (switchable) as NO contact: closes for fault/operation Contact loading max. 250 V~, 1 A 51-52 fault or operating message (switchable) as NC contact: opens for fault/operation Contact loading max. 250 V~, 1 A 7-8 Alarm external fault reporting Max. load: 250 V AC, 5 A

Alarm

54 52 51
max. 250 V 1A

54 52 51
max. 250 V 1A

7 8
max. 250 V 5A

1-2 External ON/OFF Control contact for switching the pump on and off externally 3-4 MIN Min. characteristic line 5-6 analogue input 0 10 V 5 = +10 V 6= 0V

Start/Stop Min

0-10V

+ -

1 2 3 4 5 6

26

Options

A 12 KW A 401 KW, A 500 KW 8 174 W Signal module Operating message External ON/OFF External minimum speed Twin pumps function Not possible in combination with control module Control module External speed 0 10 V / 0 20 mA External ON/OFF PWM Multitherm interface Twin pumps function Not possible in combination with signal module

A 402 V2 KW A 801 V2 KW 25 930 W

A 802 KW A 1002 KW 50 1790 W

961178_00

pump on and off externally 10-13 control contact for switching minimum speed on and off externally 61-64 operating or ready message (NO contact) 61-62 operating or ready message (NC contact) 91-92 twin pump

13 11 10 91 92

64 62 61

Control module 10-11 control contact for switching pump on and off externally 81-82 Multitherm/PWM interface 71-72 analogue input 010 V or 020 mA for external speed setting 91-92 twin pump
961177_00

81 82 71 72 11 10 91 92

27

Air-conditioning/ Refrigeration

Connection Signal module diagram 10-11 control contact for switching

A 12 KW, -1, -2
92

188 49

219 170

Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C 30 35 40

170/180 mm 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.25 A 0.14 A 833 W 819 W

A12 KW = 11/2,11/4,1,3/4 D = 2 L = 170 mm H = 235 mm

137

961302_00

A12-1 KW = 1,3/4 D = 11/2 max. 10 L = 180 mm H = 235 mm

A12-2 KW = 11/2,11/4,1,3/4 D = 2 L = 180 mm H = 245 mm

Media temperature min. C max. C 10 95 10 90 10 70

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details

1) As delivered with power limiting/Constant speed, 6

A 13 KW, -1, -2
92

188 49

219 170

Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C 30 35 40

170/180 mm 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.35 A 0.14 A 850 W 819 W

A13 KW = 11/2,11/4,1,3/4 D = 2 L = 170 mm H = 235 mm

137

961302_00

A13-1 KW = 1,3/4 D = 11/2 max. 10 L = 180 mm H = 235 mm

A13-2 KW = 11/2,11/4,1,3/4 D = 2 L = 180 mm H = 245 mm

Media temperature min. C max. C 10 95 10 90 10 70

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details

1) As delivered with power limiting/Constant speed, 6

28

A 14 KW, -1, -2
92

188 49

219 170

Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C 30 35 40

170/180 mm 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.5 A 0.14 A 870 W 819 W

A14 KW = 11/2,11/4,1,3/4 D = 2 L = 170 mm H = 235 mm

137

961302_00

A14-1 KW = 1,3/4 D = 11/2 max. 10 L = 180 mm H = 235 mm

A14-2 KW = 11/2,11/4,1,3/4 D = 2 L = 180 mm H = 245 mm

Media temperature min. C max. C 10 95 10 90 10 70

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details

A 15 KW, -1, -2
92

188 49

219 170

Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C 30 35 40

170/180 mm 10 bar 10C bis +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.8 A 0.25 A 8107 W 819 W

A15 KW = 11/2,11/4,1,3/4 D = 2 L = 170 mm H = 235 mm

137

961302_00

A15-1 KW = 1,3/4 D = 11/2 max. 10 L = 180 mm H = 235 mm

A15-2 KW = 11/2,11/4,1,3/4 D = 2 L = 180 mm H = 245 mm

Media temperature min. C max. C 10 95 10 90 10 70

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details

1) As delivered with power limiting/Constant speed, 6

29

Air-conditioning/ Refrigeration

1) As delivered with power limiting/Constant speed, 6

A 16-1 KW, A 16-2 KW


92

188 49

219 170

Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C 30 35 40

180 mm 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3,8 kg 1230 V, 50 Hz 0.11.25 A 0.14 A 8174 W 819 W

A 16-1 KW = 1,3/4 D = 11/2 L = 180 mm H = 235 mm

137

max. 10
961302_00

A 16-2 KW = 11/2,11/4,1,3/4 D = 2 L = 180 mm H = 245 mm

Media temperature min. C max. C 10 95 10 90 10 70

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details

1) As delivered with power limiting/Constant speed, 6

A 401 KW, A 401-1 KW


92

188 242 40 56 167 110 100

Installation length A 401 KW A 401-1 KW Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C 30 35 40

220 mm 250 mm 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 9 kg 1230 V, 50 Hz 0.11.25 A 0.14 A 8174 W 819 W

A 401 KW L = 220 mm A = 110 mm


14

18 A 88 max. 10 150

A 401-1 KW L = 250 mm A = 125 mm

Media temperature min. C max. C 10 95 10 90 10 70

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details

1) As delivered with power limiting/Constant speed, 6

30

L
961303_00

A 500 KW
92

188

Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C 30 35 40

220 mm 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 1230 V, 50 Hz 0.11.25 A 0.14 A 8174 W 819 W

50

57

249.2 166.7

125 110

220

14 110 18 102 max. 10


961399_00

165

Media temperature min. C max. C 10 95 10 90 10 70

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details

31

Air-conditioning/ Refrigeration

1) As delivered with power limiting/Constant speed, 6

A 402 V2 KW, A 402-1 V2 KW


Installation length A 402 V2 KW 220 mm A 402-1 V2 KW 250 mm Permissible operating pressure 6 16 bar Permissible operating temp. 10C to +95C Ambient temperature max. 40C Required operating pressure at 500 m a.s.l. at 75C water temperature 0.10 bar at 95C water temperature 0.85 bar For every 100 m altitude 0.01 bar Weight 16.5 kg Voltage 1230 V, 50 Hz Current Regulation 0.252 A min 0.33 A Power Regulation 25420 W min 3065 W Ambient temp. C max. 40 Media temperature min. C max. C 10 95

306 231 61 251

B1

1/4"

PN 6-16

40

161

110 100 230

14

A 402 V2 KW L = 220 mm A = 110 mm B1 = 151 mm B2 = 84 mm

18 A 402-1 V2 KW

L = 250 mm
961306_00

88 A = 125 mm 150

max. 2m

M20x1.5

B2

116

B1 = 171 mm B2 = 94 mm

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details

1) As delivered with power limiting/Constant speed, 6

A 501 V2 KW
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C max. 40 270 mm 6 16 bar 10C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.65 bar 0.01 bar 20.5 kg 1230 V, 50 Hz 0.251.3 A 0.4 A 35275 W 3065 W

318 236 76 251

190 50

1/4"

PN 6-16

161

125 110

135

14 18
102 165

270

961307_00

max. 2m

M20x1.5

107

116

Media temperature min. C max. C 10 95

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details

1) As delivered with power limiting/Constant speed, 6

32

230

A 502 V2 KW
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C max. 40 270 mm 6 16 bar 10C to +95C max. 40C 500 m a.s.l. 0.20 bar 0.65 bar 0.01 bar 21 kg 1230 V, 50 Hz 0.453.4 A 1A 70720 W 70200 W

318 236 76 251

190 50

1/4"

PN 6-16

161

125 110

135

14 18
102 165

270

961307_00

max. 2m

M20x1.5

107

116

Media temperature min. C max. C 10 95

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details

A 651 V2 KW, A 651-1 V2 KW


Installation A 651 KW V2 length A 651-1 KW V2 Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C max. 40 340 mm 270 mm 6 16 bar 10C to +95C max. 40C 500 m a.s.l. 0.35 bar 1.45 bar 0.01 bar 24 kg 1230 V, 50 Hz 1.22.4 A 0.7 A 50515 W 50145 W

T1 241 T2 251

B1 65
1/4" PN 6-16

161

145 130 230

A 651 V2 KW L = 340 mm A = 170 mm B1 = 207 mm B2 = 119 mm T1 = 381 mm T2 = 81 mm


14 18

961308_01

122 185

max. 2m

M20x1.5

B2

116

A 651-1 V2 KW L = 270 mm A = 135 mm B1 = 179 mm B2 = 98 mm T1 = 391 mm T2 = 73 mm

Media temperature min. C max. C 10 95

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details

1) As delivered with power limiting/Constant speed, 6

33

Air-conditioning/ Refrigeration

1) As delivered with power limiting/Constant speed, 6

230

A 652 V2 KW
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C max. 40 340 mm 6 16 bar 10C to +95C max. 40C 500 m a.s.l. 0.35 bar 1.45 bar 0.01 bar 25 kg 1230 V, 50 Hz 0.484.3 A 1A 70930 W 70220 W

333 241 81 251

207 65
1/4" PN 6-16

161

145 130

340

230

14 18

170

961308_00

122 185

max. 2m

M20x1.5

119

116

Media temperature min. C max. C 10 95

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details

1) As delivered with power limiting/Constant speed, 6

A 801 V2 KW
Installation length Permissible operating pressure Special design Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C max. 40 360 mm 6 bar 16 bar 10C to +95C max. 40C 500 m a.s.l. 0.35 bar 1.45 bar 0.01 bar 27 kg 1230 V, 50 Hz 0.484.3 A 1A 70930 W 70220 W

371 271

62

251

193 80

PN 6 1/4"

PN 16

150 18

160 18

161

180

360

961393_00

230

128 200

128 200

max. 2m

M20x1.5

107

116

Media temperature min. C max. C 10 95

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details

1) As delivered with power limiting/Constant speed, 6

34

A 802 KW
Installation length Permissible operating pressure Special design Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature at 110C water temperature For every 100 m altitude Weight Voltage Current Regulation Power Regulation Ambient temp. C max. 40 360 mm 6 bar 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.6 bar 1.0 bar 1.7 bar 0.01 bar 32 kg 1230 V, 50 Hz 0.59.3 A 501790 W

132

100 80 97

506 409

PN 6 160 150

PN 10 160 18

360

250

961333_00

128 200

18

128 200

196

Media temperature min. C max. C 10 95

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection.

A 1002 KW
Installation length Permissible operating pressure Special design Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature at 110C water temperature For every 100 m altitude Weight Voltage Current Regulation Power Regulation Ambient temp. C max. 40 450 mm 6 bar 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.6 bar 1.0 bar 1.7 bar 0.01 bar 32 kg 1230 V, 50 Hz 0.59.3 A 501790 W

135

100 100 120

530 410

PN 6 170 18

PN 10 180 18

450

250

961347_00

160 220

160 220

196

Media temperature min. C max. C 10 95

The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection.

1) As delivered with power limiting/Constant speed, 6

35

Air-conditioning/ Refrigeration

1) As delivered with power limiting/Constant speed, 6

36

Twin pumps
AD 401 KW AD 402 V2 KW AD 652 V2 KW AD 802 KW

List of models

DN 40

Installation dimension 40220 mm 40250 mm 50270 mm 65340 mm 80360 mm

Type AD 401 KW AD 402-1 V2 KW AD 501 V2 KW, AD 502 V2 KW AD 651 V2 KW, AD 652 V2 KW AD 802 KW

Perm. operating pressure PN 6/10 PN 6-16 PN 6-16 PN 6-16 PN 6 G/PN 10

Energy class A A A A A

50 65 80

KW = modified version for cold water application. With special coating resistant to condensed water.

37

Air-conditioning/ Refrigeration

G Standard design Special design

AD 401 KW
AD 401 KW A 401 KW The pumps are designed for individual operation in systems with higher safety requirements (P1 or P2) Parallel operation (P1 + P2) only permitted in constant speed mode (cs) or with external speed setting (0 10 V/0 20 mA) but not in controlled operation mode (cp or pp) Optional: Control module (2 ) Signal module (2 ) Both module types with integral twin pump function 22h / 2h alternating operation

AD 401 KW
236 297 50 174 PN 6-10 110 100

220

14 18

961304_00

88 150

AD 402 V2 KWAD 652 V2 KW


T1

251 B2 T2 B3

B1 B4
1/4"

161
PN 6-16

116 230

k2 k1 14

AD 402-1 V2 KW AD 501 V2 KW AD 502 V2 KW AD 651 V2 KW AD 652 V2 KW

A 402-1 V2 KW A 501 V2 KW A 502 V2 KW A 651 V2 KW A 652 V2 KW

T3

M20x1.5

L1 L2

L3

18 DN
max. 2m

The pumps are designed for individual operation in systems with higher safety requirements (P1 or P2) Parallel operation (P1 + P2) only permitted in constant speed mode (cs) or with external speed setting (0 10 V/0 20 mA) but not in controlled operation mode (cp or pp) Optional: Control module (2 ) Signal module (2 ) Both module types with integral twin pump function 22h / 2h alternating operation

961309_00

AD 402-1 V2 KW AD 501 V2 KW AD 502 V2 KW AD 651 V2 KW AD 652 V2 KW PN 6-16 DN L1 B1 B2 B3 B4 D k1 (PN 6) k2 (PN 10/16) L2 L3 T1 T2 T3 M 40 250 387 91 72 108 150 100 110 144 112 294 73 219 M 20 1.5 M 16 1.5 kg 35 PN 6-16 50 270 473 102 132 123 165 110 125 124 115 301 83 218 M 20 1.5 M 16 1.5 50 PN 6-16 50 270 473 102 132 123 165 110 125 124 115 301 83 218 M 20 1.5 M 16 1.5 50 PN 6-16 65 340 491 110 130 135 185 130 145 158 152 322 93 220 M 20 1.5 M 16 1.5 60 PN 6-16 65 340 491 110 130 135 185 130 145 158 152 322 93 220 M 20 1.5 M 16 1.5 60

AD 802 KW
479 497 97 400

AD 802 KW

A 802 KW

80

PN 6 150 18

PN 10 160 18

360

Alternating operation, 24h/24h See page 48 for further details Refer to individual pump for technical data

160

250

The pumps are designed for individual operation in systems with higher safety requirements (P1 oder P2)

128
961334_00

128 200

121

120

120

118

200

38

Intelligent service water pumps


AXW smart
Die smart-Technologie erkennt die Verbrauchsgewohnheiten in Ihrem Haushalt und schaltet die Pumpe vorausschauend ein und aus. 1 230 V

List of models

DN

Installation dimensions 11/4120 mm

Type AXW 10 smart AXW 12 smart AXW 13 smart AXW 14 smart

Permissible operating pressure PN 10 PN 10 PN 10 PN 10

11/4150 mm

Installation conditions
Optimum spacing of cable box with temperature sensor from hot water heater: 20 to 50 cm Determine spacing from pump to fitting position of cable box with temperature sensor. Draw sensor cable from cable box with the required cable length. The length of the sensor cable is 2.5 m
20-50cm

7 1 6 4
1 Pump 2 Cable box with temperature sensor 3 Sensor cable (2.5 m) 4 Cable binders 5 Hot water heater 6 Return valve (Return flow valve) 7 Ball valve

> 50cm
961227_02

High efficiency permanent magnet technology

as heating pumps of energy class A

39

Service water

Standard

AXW smart

High-efficiency permanent magnet technology

      

Experiential smart technology recognises and anticipates your consumption habits to make hot water available Variable comfort setting from maximum energy saving to maximum comfort Legionella protection

Information via LED display

Weekend and holiday recognition

Shut-off set Non-return valve and ball valve Types of control (Proportional pressure, contact pressure and constant speed) Fault or operating message (switchable) Power limiting (can be deactivated)

Electrical connection
Pump L N = Lead = Neutral line = PE wire, protective conductor

L N

Note: Continuous voltage of 230 V required

Supply 1 230 V Back-up fuse 10 A

Options
Sensor cable (5 m) Signal module

Control module

Thermal insulation shells

40

961314_00

AXW 10 smart
Installation length 120 mm Permissible operating pressure 10 bar Permissible operating temperature +15C to +65C (for shorts periods max. 85 C for thermal disinfection). To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temperature max. 40 C Water hardness max. 35fH (20dH) Required operating pressure at 500 m a.s.l. at 65C water temperature 0.05 bar at 85C water temperature 0.30 bar For every 100 m altitude 0.01 bar Weight 2.4 kg Voltage 1230 V, 50 Hz Current 0.040.1 A Power 4.78.4 W The pump is fitted with internal electric motor protection and requires no external motor protection. The pump always starts with a high torque. Pump housing: bronze Incl. Shut-off set (Non-return valve and ball valve) See page 49 for further details

124 78 G1"

164.8 134.3 30.5 G1 1/4"

217

120

G1" max. 10

AXW 12 smart
Installation length 120 mm Permissible operating pressure 10 bar Permissible operating temperature +15C to +65C (for shorts periods max. 85 C for thermal disinfection). To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temperature max. 40 C Water hardness max. 35fH (20dH) Required operating pressure at 500 m a.s.l. at 65C water temperature 0.05 bar at 85C water temperature 0.30 bar For every 100 m altitude 0.01 bar Weight 2.4 kg Voltage 1230 V, 50 Hz Current 0.070.15 A Power 8.719 W The pump is fitted with internal electric motor protection and requires no external motor protection. The pump always starts with a high torque. Pump housing: bronze Incl. Shut-off set (Non-return valve and ball valve) See page 49 for further details

124 78 G1"

164.8 134.3 30.5 G1 1/4"

217

120

G1" max. 10

961429_00

961429_00

41

Service water

AXW 13 smart
Installation length 150 mm Permissible operating pressure 10 bar Permissible operating temperature +15C to +65C (for shorts periods max. 85 C for thermal disinfection). To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temperature max. 40 C Water hardness max. 35fH (20dH) Required operating pressure at 500 m a.s.l. at 65C water temperature 0.05 bar at 85C water temperature 0.30 bar For every 100 m altitude 0.01 bar Weight 2.6 kg Voltage 1230 V, 50 Hz Current 0.120.3 A Power 14.332.7 W The pump is fitted with internal electric motor protection and requires no external motor protection. The pump always starts with a high torque. Pump housing: bronze Incl. Shut-off set (Non-return valve and ball valve) See page 49 for further details

124 78 G1"

164.8 134.3 30.5 G1 1/4"

247

150

G1" max. 10

AXW 14 smart
Installation length 150 mm Permissible operating pressure 10 bar Permissible operating temperature +15C to +65C (for shorts periods max. 85 C for thermal disinfection). To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temperature max. 40 C Water hardness max. 35fH (20dH) Required operating pressure at 500 m a.s.l. at 65C water temperature 0.05 bar at 85C water temperature 0.30 bar For every 100 m altitude 0.01 bar Weight 2.6 kg Voltage 1230 V, 50 Hz Current 0.280.38 A Power 3245 W The pump is fitted with internal electric motor protection and requires no external motor protection. The pump always starts with a high torque. Pump housing: bronze Incl. Shut-off set (Non-return valve and ball valve) See page 49 for further details

124 78 G1"

164.8 134.3 30.5 G1 1/4"

247

150

G1" max. 10

42

961430_00

961430_00

Service water pumps


AXW / AW

List of models

DN

Installation dimensions 11/4120 mm 11/4150 mm 11/2180 mm 2180 mm 40250 mm

Type AXW 12 AXW 13 AXW 12-1, AXW 13-1 AW 15-2 AW 401-1

Permissible operating pressure PN 10 PN 10 PN 10 PN 10 PN 6 /10

40

40

40250 mm

AW 402-1 V2

PN 6 16

High efficiency permanent magnet technology

as heating pumps of energy class A

43

Service water

Standard

AXW 12, AXW 13 5 45 W High-efficiency permanent magnet technology

AW 15 AW 401 8 174 W

AW 402 V2 25 420 W

Experiential smart technology recognises and anticipates your consumption habits to make hot water available Variable comfort setting from maximum energy saving to maximum comfort Legionella protection

 

 

 

Information via LED display

Weekend and holiday recognition

Shut-off set Non-return valve and ball valve Types of control (Proportional pressure, contact pressure and constant speed) Fault or operating message (switchable) Power limiting (can be deactivated)

only for the G 11/4 design

  

  

Electrical connection
961192_00

Pump L N = Lead = Neutral line = PE wire, protective conductor

N L
Supply 1 230 V Back-up fuse 10 A

N L
Supply 1 230 V Back-up fuse 10 A

L N

Supply 1 230 V Back-up fuse 10 A

51-54 fault or operating message (switchable) as NO contact: closes for fault/operation Contact loading max. 250 V~, 1 A 51-52 fault or operating message (switchable) as NC contact: opens for fault/operation Contact loading max. 250 V~, 1 A

961191_00

54 52 51
max. 250 V 1A

54 52 51
max. 250 V 1A

Options
Signal module See page 48 for further details Control module See page 48 for further details Thermal insulation shells

  

  

only for the G 11/2 design

44

961191_00

961301_00

AXW 12, AXW 12-1


Installation length Permissible operating pressure Permissible operating temp. Permissible water hardness 120/180 mm 10 bar +15C to +85C 65C (max. 35fH = 20dH) 85C (max. 25fH = 14dH) 500 m a.s.l. 0.05 bar 0.30 bar 0.01 bar 2.3 kg 1230 V, 50 Hz 0.050.19 A 0.05 A 522 W 5W

124 78 G1"

158.4 127.9 30.5 D

AXW 12 D = 114 L = 120 mm L1 = 217 mm AXW 12-1 D = 112 L = 180 mm

L1 G1"
961431_00

Required operating pressure at at 75C water temperature at 85C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min

max. 10

H [kPa]
ma x

H [m]

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 85 30 30 85 35 35 85 40 40 70 The pump is fitted with internal electric motor protection and requires no external motor protection. Pump housing: bronze AXW 12: incl. shut-off set AXW 12-1: Shut-off set not available

min

P [W] 1

max

min
961151_00

AXW 13, AXW 13-1


Installation length Permissible operating pressure Permissible operating temp. Permissible water hardness 150/180 mm 10 bar +15C to +85C 65C (max. 35fH = 20dH) 85C (max. 25fH = 14dH) 500 m a.s.l. 0.05 bar 0.30 bar 0.01 bar 2.3 kg 1230 V, 50 Hz 0.050.38 A 0.05 A 545 W 5W

124 78 G1"

158.4 127.9 30.5 D

AXW 13 D = 114 L = 150 mm L1 = 247 mm AXW 13-1 D = 112 L = 180 mm

L1 G1"
961431_00

Required operating pressure at at 75C water temperature at 85C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min

max. 10

0 20 ft 16 12 30 8 4 0 20 10 0 0 60 P [W] 1 40 20 0 0 H0 [kPa] 50 40

v(1") 0.5 0.2 0.4

1 0.6

1.5 0.8 1.0

2 1.2

m/s 2.5 l/s 1.6 H [m] 5 4 3 2 1

m ax

The pump is fitted with internal electric motor protection and requires no external motor protection. Pump housing: bronze AXW 13: incl. shut-off set AXW 13-1: Shut-off set not available

min

961158_00

10

12

14

imp.g.p.m 20

45

Service water

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 85 30 30 85 35 35 85 40 40 70

min
0.5 1 1.5 2 2.5
max

0 3 3.5 4 4.5 5 m/h 6

AW 15-2
92

188 49

201 152

Installation length Permissible operating pressure Permissible operating temp. Permissible water hardness

Required operating pressure at at 75C water temperature at 85C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min

180 mm 10 bar +15C to +85C 65C (max. 35fH = 20dH) 85C (max. 25fH = 14dH) 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 4.2 kg 1230 V, 50 Hz 0.10.8 A 0.25 A 8107 W 819 W

961432_00

180

max. 10 2"

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 85 30 30 85 35 35 85 40 40 70 The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is fitted with fault or ready indication (switchable). Pump housing: bronze
1) As delivered with power limiting

AW 401-1
Installation length Permissible operating pressure Permissible operating temp. Permissible water hardness 250 mm 10 bar +15C to +85C 65C (max. 35fH = 20dH) 85C (max. 25fH = 14dH) 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 1230 V, 50 Hz 0.11.25 A 0.14 A 8174 W 819 W

188 92 40 75 203 149 110 100

137

14 250 137 18 88 max. 10


961400_00

125

150

Required operating pressure at at 75C water temperature at 85C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 85 30 30 85 35 35 85 40 40 70 The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is fitted with fault or ready indication (switchable). Pump housing: bronze
1) As delivered with power limiting

46

AW 402-1 V2
Installation length Permissible operating pressure Permissible operating temp. Permissible water hardness 250 mm 10 bar +15C to +85C 65C (max. 35fH = 20dH) 85C (max. 25fH = 14dH) 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 1230 V, 50 Hz 0.252 A 0.33 A 25420 W 3065 W

354 279 61

151 40 1/4"

PN 6-16 110 100

110

220

961433_00

88 84 160 150

Required operating pressure at at 75C water temperature at 85C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min

M20x1.5

M16x15

To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 85 30 30 85 35 35 85 40 40 70 The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is fitted with fault or ready indication (switchable). Pump housing: bronze
1) As delivered with power limiting

47

Service water

Options
Signal module

Signal module
Extension for the following auxiliary functions/interfaces: External operating indication External ON/OFF External switching of minimum speed Interface for twin pumps function Note: Not possible in combination with control module
961267_00

961178_00

13 11 10 91 92

64 62 61

Connection diagram 10-11 control contact for switching pump on and off externally 10-13 control contact for switching minimum speed on and off externally 61-64 operating or ready message (NO contact) 61-62 operating or ready message (NC contact) 91-92 twin pump

Control module

Control module
Extension for the following auxiliary functions/interfaces: Speed adjustment via analogue interface (0 10 V or 0 20 mA) External ON/OFF Multitherm or PWM interface Interface for twin pumps function
961267_00

Note: Not possible in combination with signal module Connection diagram 10-11 control contact for switching pump on and off externally 81-82 Multitherm/PWM interface 71-72 analogue input 010 V or 020 mA for external speed setting 91-92 twin pump

961177_00

81 82 71 72 11 10 91 92

Thermal insulation shells


Fire protection class B2 to DIN 4102
B1

B
T1

961194_00

Pump type AX 12, AX 12-1, AX 12-2 AX 13, AX 13-1, AX 13-2 AXW 12-1, AXW 13-1 A 12, A 12-1, A 12-2 A 13, A 13-1, A 13-2 A 14, A 14-1, A 14-2 A 15, A 15-1, A 15-2 A 16-1, A 16-2 AW 15-2 A 401, A 401-1, AW 401-1 A 402 V2 A 402-1 V2, AW 402-1 V2 A 500 A 501 V2, A 502 V2 A 651 V2, A 652 V2 A 651-1 V2 A 801 V2 A 802 A 1002
1)

Type WD 1 1)

B 140

B1 70

H 140

T 90

T1 50

WD 2

150

75

140

108

70

WD 3 WD 4 WD 5 WD 11 WD 6 WD 7 WD 12 WD 8 WD 9 WD 10

150 210 230 167 260 280 240 280 300 320

75 105 115 83.5 130 140 120 140 150 160

178 179 209 174 225 293 222 310 310 395

140 154 154 151 174 185 183 214 200 225

78 82 82 84 97 103 96 102 130 153

The AX pump is supplied with thermal insulation WD 1

48

Options
Construction set for offset electronics installation
Media temperature: up to 110 C Ambient temperature: max. 40 C Pump can be insulated up to 100 C medium temperature Note: If condensation forms (medium temperature lower than ambient temperature) it is recommended to use the cold water version (KW) with coating resistant to condensation.

116 161

max. 2m

Construction set for A A A A A A A A

402 V2 402-1 V2 501 V2 502 V2 651-1 V2 651 V2 652 V2 801 V2

Shut-off set for service water


(Non-return valve and ball valve) The shut-off set is included as standard with the following pumps: AXW 10 smart, AXW 12 smart AXW 13 smart, AXW 14 smart AXW 12, AXW 13 For AXW 12-1 and AXW 13-1 not available

Ball valve

Non-return valve

53 40

961221_00

230

G 1 1/4"

961396_00

961395_00

Material: Brass

Material: Brass Opening pressure: 2035 mbar

G 1 1/4"

G 1"

G 1"

Biral AG Sdstrasse 10 CH-3110 Mnsingen T +41 (0) 31 720 90 00 F +41 (0) 31 720 94 42 E-Mail: info@biral.ch www.biral.ch

Biral Ltd. Mnsingen, Swiss Headquarters

Biral GmbH Przisionspumpen Freiherr-vom-Stein-Weg 15 D-72108 Rottenburg am Neckar T +49 (0) 7472 16 33 0 F +49 (0) 7472 16 34 0 E-Mail: info@biral.de www.biral.de

Biral Pompen B.V Printerweg 13 3821 AP Postbus 2650 3800 GE NL-Amersfoort T +31 (0) 33 455 94 44 F +31 (0) 33 455 96 10 E-Mail: info@biral.nl www.biral.nl

Nr. 02/11 08 0445.0111_03 - Printed in Switzerland