Professional Documents
Culture Documents
Birals partners are among the best. Together we do our utmost to offer the final consumer a perfect service. A whole range of services help our partners to achieve their own high quality, economical performance. These services include: Service team Our personnel is on hand to offer fitters help and advice around the clock, seven days a week. Not only is our personnel familiar with our own pumps: our service team members also have expert knowledge of all kinds of different heating systems. They know where problems can occur and the solutions that are available. Delivery service We deliver pumps and spare parts where theyre needed. If necessary immediately, even before the heating system has had time to cool down.
Hotline A team of qualified experts advise fitters and planning engineers whenever they require support. Quickly and without fuss, so that problems can be solved on the spot whenever they arise. Documentation The more complex and varied heating systems become, the more crucial the correct choice and installation of the pumps. Our documentation, catalogues and PC programs considerably simplify these procedures. Training programs For fitters, planning engineers and junior personnel. Topics go far beyond the range and technology of our own pumps. They also include sales issues and general matters of work organization and business management. These services are financed through the price of our pumps, which are slightly higher than those of our competitors. Our successful customers have long known that nowadays there is nothing to be gained financially by purchasing a pump a little more cheaply. By paying just that little bit more, you can save time, avoid irritation, and prevent malfunctions. And thats what our services are there for.
Advice Product structure according to application situation Outstanding pumps Swiss quality Product range Consulting services Long-term follow-up and support
Earnings potential
Introduction
Page 2 3 4 6 10 Biral innovator of energy label A technology Quality features of Biral heating circulating pumps The right pump at the right place Notes for project planning and installation Standards and obligations Old circulation pumps are true energy guzzlers Schedule for eco-design guidelines
Heating circulation pumps You enjoy your cosy warm home. And the Mini-Energy pump from Biral allows the heating water to circulate. Silently and with maximum efficiency!
Page 11 23
Cold water circulation pumps 31C outside temperature. The air-conditioning in the office ensures a comfortable working atmosphere. And the Mini-Energy cold water pump from Biral plays its part. With maximum efficiency.
Page 25 37 Single pumps Twin pumps
Intelligent service water pumps You turn on the shower as usual. And the AXW-smart from Biral already knows. Thanks to smart-technology!
Page 39
AXW smart
Service water pumps Seepark Hotel, Thoune. The man in suite 57 turns on the shower. And Biral AXW is on the spot with maximum efficiency.
Page 43
AXW, AW
Service water
Service water
Air-conditioning/ Refrigeration
Heating
A
T TES ON d ct PS oo du UM yg pro GP Ver wiss A 12-1 TIN ch e S type ipp. HEA Th w.kt
al Bir
ww 3 90 4 25 : 04 rvice o-Se Ab 17 266 044 ion: dakt Re r tobe 3. Ok 16 Nr. 2007 17 90
007 9/2
Biral with EU energy label A One of the most effective methods countries can use to reduce the increasingly alarming pollution of the environment is to help make consumers aware of the consequences of their actions and indicate ways in which they can act more responsibly. If, in addition, costs simultaneously and increasingly punish negligent behaviour, as in the case of energy, there is added incentive to take remedial action. Electrical appliances, to which pumps also belong, are designated throughout Europe with standard labels. Coloured arrows indicate the energy efficiency of the appliance. This is subdivided into seven so-called energy classes: a class A appliance is particularly economical, while units of class G consume a great deal of energy. In this way the consumer can assess at a glance the energy efficiency of a unit.
Biral mini-energy pumps since 2000 As long ago as November 2000, Biral won the Wuppertal energy and environment prize, in addition to the Swiss Prix Eta Plus. This was achieved with the heating circulating pump MC 10, the efficiency of which exceeded all previous values.
AXW smart the intelligent Mini-Energy service water pump The world innovation AXW smart was distinguished with the VSK award at the VSK trade-fair in Utrecht. The jury congratulated Biral on this new product. The self-taught pump ensures maximum comfort with massive energy savings. The smart technology learns your consumption habits and provides hot water at the right time.
Biral Pioneers in power-saving heating circulation pumps The Product Test foundation tested nine heating pumps. The test criteria were energyefficiency, handling and suitable design for recycling. The Biral pump is highly economical and received the distinction very good!
Biral was already a leader at that time with regard to efficiency and has gradually enhanced its superiority. In the meantime of course heating systems of all sizes can be fitted with pumps bearing the A-label for maximum energy efficiency: for the sake of the environment and for greater operating reliability to save energy costs.
Field of application
1- or 2-family home
A
Mini-Energy pumps Standard pumps Mini-Energy pumps
AX 12 13
MX 10 13 LX 321 323
Twin pumps
Heating
Air-conditioning/ Refrigeration
A 12 KW A 401 KW
MX 10 13 LX 321 323
WX 10 13
A
Standard pumps Mini-Energy pumps Standard pumps
M 14 15 LX 325 L 1004
HX 301 802
M 14 15 LX 325 L 1004
HX 301 802
Recommendation for regulated circulating pumps Regulated circulating pumps continually adjust the flowrate along a pre-defined characteristic with changing pipe characteristics.
Nevertheless it is also worthwhile here to make a careful choice of the right pump size.
If the operating pressure is too low, adequate lubrication of the pump sliding bearings (water lubrication) is not ensured and therefore their service life is reduced. The values specified should therefore be observed without fail. The required operating pressure depends on the type of pump, the maximum temperature of the medium and the static pressure. If the position of the expansion vessel is not ideal, the operating pressure at the pump inlet when operating the pump can be reduced further (see fig. 2).
This can lead to penetration of air and inadequate bearing lubrication. In this case the static operating pressure must be raised accordingly.
H E
Fig.: Choice of regulated pumps A = Optimum control range Range with the best degree of overall effectiveness B = Limited control range If possible select a smaller pump C = Limited control range The pump works but has limited control D = Outside the control range If possible avoid
Fig. 2: Pressure distribution = Overpressure range = Underpressure range E = Expansion vessel N = Neutral point H = Delivery head of pump
3. Requirements of medium
4. Pipeline connection and pump installation Anti-frost mixture Water/glycol mixture with up to 50% glycol is permitted. From 10% glycol proportion the delivery data of the pumps must be corrected according to fig. 3. Example H mixture = 30 kPa Q mixture = 7 m3/h Medium: 50% glycol mixture at 10 C operating temperature Factors according to fig. 4: Fh = 1,26 Fq = 1,57 Conversion of required pump operating point for water heat transfer H water = H mixture Fh = 30 1,26 = 37,8 kPa Q water = Q mixture Fq = 71,57 = 11 m3/h Circulating pump complying with operating point Q water / H water: Biral A 402 V2 Always fit pump between two shut-off devices Fit pump so that the motor shaft is horizontal, regardless of the position of the pump casing (fig. 4) The arrow on the pump casing shows the flow direction (fig. 5) Fit pump in pipeline free from stress When the pump is fitted do not work too closely with a welding flame The fitting of heating pumps on the inlet side reduces the danger of contamination. They should preferably be fitted on the return side if the temperature of the medium is very high.
Water treatment The guidelines of SWKI 97-1 and VDI 2035 Water treatment for heating, steam and air-conditioning systems should be observed. Overall hardness 7 to 14 fH (4-8 dH) pH value 8.3 to 9.5 (8.3 to max. 9 for systems with aluminium or non-ferrous metal components) Oxygen <0,1 mg/dm3 The systems must be thoroughly flushed before filling.
961083_00
Operating temperature C Fig. 3: Correction factors for pump characteristic compared with water delivery Fig. 4: Fitting pump
961082_00
The regulated pumps can be operated in three different modes: Regulation with proportional operating pressure (PP) The internal regulation increases the differential pressure of the system with increasing flowrates. This desired regulation curve can be preset. This regulation is particularly suitable for the following systems: Two-pipe heating systems with thermostatic valves and long pipe sections valves with wide working range high pressure losses Floor heating systems with thermostatic valves and high pressure losses Systems with primary circuit pumps with high pressure loss. Regulation with constant operating pressure (CP) The internal regulation keeps the differential pressure of the system constant if the flowrate changes. This pressure can be preset. This regulation is particularly suitable for the following systems: Two-pipe systems with thermostatic valves and delivery head less than 2 m natural circulation (low pressure loss, large pipe dimensions) Floor heating systems with thermostatic valves Single-pipe heating systems with thermostatic valves and regulating valves Systems with primary circuit pumps with low pressure loss Regulation with constant speed (CS) With this form of regulation the internal pressure regulation is switched off. The speed of the pump can be adjusted to a constant value manually or by an external signal (auxiliary module 0 10 V). This form of regulation is particularly suitable for systems with constant pressure conditions (heat exchangers, boiler feed pumps, etc.) or for external system regulation.
Choice of regulation characteristic With changing pipeline resistance (K 1 K 2) regulated circulating pumps continuously adjust the flowrate along a pre-defined characteristic curve (fig. 6). The required regulation characteristic can be set by means of the rotary switch or key A2 (fig. 8).
Power limiting All regulated circulating pumps are supplied with preset power limiting. This characteristic curve is sufficient owing to the power reserve in the design. The limiting also saves energy and flow noise is reduced owing to over-dimensioned pumps. If full power is required, the pump can be changed over in the terminal box (see operating instructions).
Operation Regulated circulating pumps can be operated in three different regulation modes and in part have a so-called automatic minimum speed.
LED 1
A1: A2:
A2
LED 2
A3:
Form of regulation Regulation characteristics 15 6 max. pump characteristic Illuminated symbol for fault, ext. operation Proportional pressure Constant pressure Constant speed
A1
A3
Aut.
LED 1: Indication of regulation characteristic set LED 2: Indication of current rate . of flow V (25 100%)
From 1 January 2013, the energy efficiency index (EEI) of external wet rotor circulation pumps must not exceed a value of 0.27.
st
From 1st August 2015, the energy efficiency index (EEI) of external wet rotor circulation pumps, and wet rotor pumps integrated into products, must not exceed a value of 0.23. In April 2010, Biral removed traditionally controlled circulation pumps from its range and is already focused on the new energy-efficient technology, for heating as well as coldwater pumps. Biral is therefore already making a vital contribution to CO2 reduction.
EEI >0.23
Drinking water circulation pumps do not come under the eco-design guidelines. Nevertheless, Biral is already introducing high-efficiency energy-saving pumps into its range for this category.
10
11
Heating
Standard
AX 12, AX 13 5 45 W
Fault reporting
External speed, 0 10 V
1)
961192_00
N L
N L
L N
51-54 fault or operating message (switchable) as NO contact: closes for fault/operation Contact loading max. 250 V~, 1 A 51-52 fault or operating message (switchable) as NC contact: opens for fault/operation Contact loading max. 250 V~, 1 A 7-8 Alarm external fault reporting Max. load: 250 V AC, 5 A
Alarm
54 52 51
max. 250 V 1A
54 52 51
max. 250 V 1A
7 8
max. 250 V 5A
1-2 External ON/OFF Control contact for switching the pump on and off externally 3-4 MIN Min. characteristic line 5-6 analogue input 0 10 V 5 = +10 V 6= 0V
Start/Stop Min
0-10V
+ -
1 2 3 4 5 6
12
1) Pumps AX 12,-1 -2, AX 13 -1,-2 are fitted as standard with a thermal insulation shell
Options
AX 12, AX 13 5 45 W
Signal module Operating message External ON/OFF External minimum speed Twin pumps function Not possible in combination with control module Control module External speed 0 10 V / 0 20 mA External ON/OFF PWM Multitherm interface Twin pumps function Not possible in combination with signal module Thermal insulation shells
961178_00
13 11 10 91 92
64 62 61
Control module 10-11 control contact for switching pump on and off externally 81-82 Multitherm/PWM interface 71-72 analogue input 010 V or 020 mA for external speed setting 91-92 twin pump
961177_00
81 82 71 72 11 10 91 92
13
Heating
124 78 29
158.4 129.4
AX 12-1 = 1,3/4 D = 11/2 L = 180 mm H = 235 mm AX 12-3 = 1,3/4 D = 11/2 L = 130 mm H = 185 mm AX 12-4 = 1/2 D = 1 L = 130 mm H = 178 mm
961156_00
D
50.2
140
H [kPa]
ma x
H [m]
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 110 30 30 110 35 35 90 40 40 70 The pump is fitted with internal electric motor protection and requires no external motor protection. The pumps AX 12,-1,-2 are fitted with a thermal insulation shell.
min
P [W] 1
max
min
961056_02
124 78 29
158.4 129.4
AX 13-1 = 1,3/4 D = 11/2 L = 180 mm H = 235 mm AX 13-3 = 1,3/4 D = 11/2 L = 130 mm H = 185 mm AX 13-4 = 1/2 D = 1 L = 130 mm H = 178 mm
961156_00
D
50.2
140
0 20 ft 16 12 8 4 0 H0 [kPa] 50 40 30 20 10 0 60 P [W] 1 40 20 0 0 0
1 0.6
2 1.2
m/s
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 110 30 30 110 35 35 90 40 40 70 The pump is fitted with internal electric motor protection and requires no external motor protection. The pumps AX 13,-1,-2 are fitted with a thermal insulation shell.
ma
min
0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 m/h 6
1 0
max
min 2 4 6 8 10 12 14
961057_01
imp.g.p.m 20
14
A 12, -1, -2
92
188 49
201 152
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min
170/180 mm 10 bar +15C to +110C 2) max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.25 A 0.14 A 833 W 819 W
137
max. 10
960947_00
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90 40 40 70 2) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module See page 48 for further details
1) As delivered with power limiting
A 13, -1, -2
92
188 49
201 152
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min
170/180 mm 10 bar +15C to +110C 2) max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.35 A 0.14 A 850 W 819 W
137
max. 10
960947_00
0 20 ft 16 12 30 8 4 0 20 10 0 0 60 P [W] 1 40 20 0 0 H0 [kPa] 50
1 0.6
2 1.2
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90 40 40 70 2) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module See page 48 for further details
1) 40 5
5 4
6m ax
3
4 3 2 1
3
2 1
2 1 0 4.5 5 m/h 6
min
0.5 1 1.5 2 2.5 3 3.5 4
6 max
1
min
960990_02
10
12
14
imp.g.p.m 20
15
Heating
A 14, -1, -2
92
188 49
201 152
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min
170/180 mm 10 bar +15C to +110C 2) max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.5 A 0.14 A 870 W 819 W
137
max. 10
960947_00
0 H [kPa] 60 50 40 30 8 4 0 20 10 0 0 70 P1 [W] 40 20 0 0 5 4 0
v(1") 0.4
1.5 0.8
2 1.2
2.5 1.6
m/s
3.5 2 l/s
4 2.4 H [m] 6 5 4
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90 40 40 70 2) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module See page 48 for further details
20 ft 16 12
1)
6m ax 4
3
3
2 1
3 2 1 1
6 max
2 1 0 7 m/h 9
min
2 3 4 5 6
1
min
960955_02
12
15
18
21 imp.g.p.m
30
A 15, -1, -2
92
188 49
201 152
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min
170/180 mm 10 bar +15C to +110C 2) max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.8 A 0.25 A 8107 W 819 W
137
max. 10
960947_00
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90 40 40 70 2) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module See page 48 for further details
5 4 3
2 1
16
A 16-1, A 16-2
92
188 49
201 152
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min
180 mm 10 bar +15C to +110C 2) max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.8 A 0.25 A 8107 W 819 W
137
max. 10
960947_00
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90 40 40 70 2) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module See page 48 for further details
6m ax
150
2
960948_01
A 401, A 401-1
92
188
Installation length A 401 A 401-1 Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min
220 mm 250 mm 10 bar +15C to +110C 2) max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 9 kg 1230 V, 50 Hz 0.11.25 A 0.14 A 8174 W 819 W
18 88
max. 10
960989_00
137
150
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90 40 40 70 2) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module See page 48 for further details
6m ax
150
2
960948_01
17
Heating
A 500
92
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min
220 mm 10 bar +15C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 1230 V, 50 Hz 0.11.25 A 0.14 A 8174 W 819 W
110
165
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90/110 2) 40 40 70/110 2) The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module 2) construction set for offset electronics installation See page 48 for further details
6m ax
150
2
960948_01
18
354 279 61
B1 40 1/4"
961180_00
88 B2 160 150
M20x1.5
M16x15
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90/110 2) 40 40 70/110 2) The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module 2) construction set for offset electronics installation See page 48 for further details
A 501 V2
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min 270 mm 6 16 bar +15C to +95C max. 40C 500 m a.s.l. 0.20 bar 0.65 bar 0.01 bar 18.5 kg 1230 V, 50 Hz 0.251.3 A 0.4 A 35275 W 365 W
366 284 76
190 50 1/4"
270
14 18 102
961181_00
135
M20x1.5
M16x15
107
160
165
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90/110 2) 40 40 70/110 2) The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module 2) construction set for offset electronics installation See page 48 for further details
1) As delivered with power limiting
19
Heating
A 502 V2
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min 270 mm 6 16 bar +15C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.65 bar 0.01 bar 19 kg 1230 V, 50 Hz 0.453.4 A 1A 70720 W 70200 W
366 284 76
190 50 1/4"
270
14 18 102
961181_00
135
M20x1.5
M16x15
107
160
165
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90/110 2) 40 40 70/110 2) The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module 2) construction set for offset electronics installation See page 48 for further details
1) As delivered with power limiting
T1 289 T2
B1 65 1/4"
B2
160
185
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90/110 2) 40 40 70/110 2) The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module 2) construction set for offset electronics installation See page 48 for further details
20
A 652 V2
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min 340 mm 6 16 bar +15C to +95C max. 40C 500 m a.s.l. 0.35 bar 1.45 bar 0.01 bar 23 kg 1230 V, 50 Hz 0.484.3 A 1A 70930 W 70220 W
381 289 81
207 65 1/4"
340
14 18 122
M20x1.5
M16x15 961182_00
170
119
160
185
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90/110 2) 40 40 70/110 2) The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module 2) construction set for offset electronics installation See page 48 for further details
1) As delivered with power limiting
A 801 V2
Installation length Permissible operating pressure Special design Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min 360 mm 6 bar 16 bar +15C to +95C max. 40C 500 m a.s.l. 0.35 bar 1.45 bar 0.01 bar 25 kg 1230 V, 50 Hz 0.484.3 A 1A 70930 W 70220 W
193 80 1/4"
PN 6 150 18
PN 16 160 18
180
360
128 200
107
160
200
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 2) 30 30 95/110 2) 35 35 90/110 2) 40 40 70/110 2) The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell Control module, signal module 2) construction set for offset electronics installation See page 48 for further details
21
Heating
A 802
Installation length Permissible operating pressure Special design Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature at 110C water temperature For every 100 m altitude Weight Voltage Current Regulation Power Regulation 360 mm 6 bar 10 bar +15C to +95C max. 40C 500 m a.s.l. 0.6 bar 1.0 bar 1.7 bar 0.01 bar 32 kg 1230 V, 50 Hz 0.59.3 A 501790 W
132
100 80 97
506 409
PN 6 160 150
PN 10 160 18
360
250
961333_00
128 200
18
128 200
196
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 1) 30 30 95/110 1) 35 35 90/110 1) 40 40 70/110 1) 1) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell See page 48 for further details
1) As delivered with power limiting
A 1002
Installation length Permissible operating pressure Special design Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature at 110C water temperature For every 100 m altitude Weight Voltage Current Regulation Power Regulation 450 mm 6 bar 10 bar +15C to +95C max. 40C 500 m a.s.l. 0.6 bar 1.0 bar 1.7 bar 0.01 bar 32 kg 1230 V, 50 Hz 0.59.3 A 501790 W
135
530 410
PN 6 170 18
PN 10 180 18
450
250
961347_00
160 220
160 220
196
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 95/110 1) 30 30 95/110 1) 35 35 90/110 1) 40 40 70/110 1) 1) for short periods, approx. 30 min The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Thermal insulation shell See page 48 for further details
1) As delivered with power limiting
22
Twin pumps
AD 401 AD 402 V2 652 V2 AD 802
List of models
DN 40
Type AD 401 AD 402-1 V2 AD 501 V2, AD 502 V2 AD 651 V2, AD 652 V2 AD 802
Energy class A A A A A
50 65 80
23
Heating
AD 401
AD 401 A 401 The pumps are designed for individual operation in systems with higher safety requirements (P1 or P2) Parallel operation (P1 + P2) only permitted in constant speed mode (cs) or with external speed setting (0 10 V/0 20 mA) but not in controlled operation mode (cp or pp) Optional: Construction set for offset electronics installation (2 ) Control module (2 ) Signal module (2 ) Both module types with integral twin pump function 22h / 2h alternating operation
AD 401
218 297 50 156 PN 6-10 110 100
220
14 18
961174_00
88 150
AD 402 V2 AD 652 V2
B1 T2
T1 T3 M
PN 6-16 k2 k1
A 402-1 V2 A 501 V2
L1
A 502 V2 A 652 V2
L2 L3
14 18 DN
961213_00
A 651 V2
The pumps are designed for individual operation in systems with higher safety requirements (P1 or P2) Parallel operation (P1 + P2) only permitted in constant speed mode (cs) or with external speed setting (0 10 V/0 20 mA) but not in controlled operation mode (cp or pp) Optional: Construction set for offset electronics installation (2 ) Control module (2 ) Signal module (2 ) Both module types with integral twin pump function 22h / 2h alternating operation
B2
B3
B4
B2
AD 402-1 V2 PN 6-16 DN L1 B1 B2 B3 B4 D k1 (PN 6) k2 (PN 10/16) L2 L3 T1 T2 T3 M 40 250 500 160 72 108 150 100 110 112 144 342 73 267 M 20 1.5 M 16 1.5 kg 30
AD 501 V2 PN 6-16 50 270 578 162 132 123 165 110 125 115 124 349 83 266 M 20 1.5 M 16 1.5 45
AD 502 V2 PN 6-16 50 270 578 162 132 123 165 110 125 115 124 349 83 266 M 20 1.5 M 16 1.5 45
AD 651 V2 PN 6-16 65 340 588 162 130 135 185 130 145 152 158 370 93 269 M 20 1.5 M 16 1.5 55
AD 652 V2 PN 6-16 65 340 588 162 130 135 185 130 145 152 158 370 93 269 M 20 1.5 M 16 1.5 55
AD 802
479 497 97 400
AD 802
A 802
80
PN 6 150 18
PN 10 160 18
360
160
Alternating operation, 24h/24h See page 48 for further details Refer to individual pump for technical data
250
The pumps are designed for individual operation in systems with higher safety requirements (P1 or P2)
128
961334_00
128 200
121
120
120
118
200
24
List of models
DN
Type A 12 KW, A 13 KW A 14 KW, A 15 KW A 12-2 KW, A 13-2 KW, A 14-2 KW A 15-2 KW, A 16-2 KW A 12-1 KW, A 13-1 KW, A 14-1 KW A 15-1 KW, A 16-1 KW A 401 KW A 401-1 KW A 500 KW A 402 V2 KW A 402-1 V2 KW A 501 V2 KW, A 502 V2 KW A 651-1 V2 KW A 651 V2 KW, A 652 V2 KW A 801 V2 KW A 802 KW A 1002 KW
40220 mm 40250 mm 50220 mm 40220 mm 40250 mm 50270 mm 65270 mm 65340 mm 80360 mm 80360 mm 100450 mm
Perm. operating pressure PN 10 PN 10 PN 10 PN 10 PN 10 PN 10 PN 6/10 PN 6/10 PN 6/10 PN 6-16 PN 6-16 PN 6-16 PN 6-16 PN 6-16 PN 6 G/PN 16 PN 6 G/PN 10 PN 6 G/PN 10
Energy class A A A A A A A A A A A A A A A A A
25
Air-conditioning/ Refrigeration
KW = modified version for cold water application. With special coating resistant to condensed water.
Standard
Fault reporting
External speed, 0 10 V
Power limiting (can be activated) Automatic night reduction (can be activated) Media temperature: up to 10 C
961192_00
N L
L N
51-54 fault or operating message (switchable) as NO contact: closes for fault/operation Contact loading max. 250 V~, 1 A 51-52 fault or operating message (switchable) as NC contact: opens for fault/operation Contact loading max. 250 V~, 1 A 7-8 Alarm external fault reporting Max. load: 250 V AC, 5 A
Alarm
54 52 51
max. 250 V 1A
54 52 51
max. 250 V 1A
7 8
max. 250 V 5A
1-2 External ON/OFF Control contact for switching the pump on and off externally 3-4 MIN Min. characteristic line 5-6 analogue input 0 10 V 5 = +10 V 6= 0V
Start/Stop Min
0-10V
+ -
1 2 3 4 5 6
26
Options
A 12 KW A 401 KW, A 500 KW 8 174 W Signal module Operating message External ON/OFF External minimum speed Twin pumps function Not possible in combination with control module Control module External speed 0 10 V / 0 20 mA External ON/OFF PWM Multitherm interface Twin pumps function Not possible in combination with signal module
961178_00
pump on and off externally 10-13 control contact for switching minimum speed on and off externally 61-64 operating or ready message (NO contact) 61-62 operating or ready message (NC contact) 91-92 twin pump
13 11 10 91 92
64 62 61
Control module 10-11 control contact for switching pump on and off externally 81-82 Multitherm/PWM interface 71-72 analogue input 010 V or 020 mA for external speed setting 91-92 twin pump
961177_00
81 82 71 72 11 10 91 92
27
Air-conditioning/ Refrigeration
A 12 KW, -1, -2
92
188 49
219 170
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C 30 35 40
170/180 mm 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.25 A 0.14 A 833 W 819 W
137
961302_00
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details
A 13 KW, -1, -2
92
188 49
219 170
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C 30 35 40
170/180 mm 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.35 A 0.14 A 850 W 819 W
137
961302_00
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details
28
A 14 KW, -1, -2
92
188 49
219 170
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C 30 35 40
170/180 mm 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.5 A 0.14 A 870 W 819 W
137
961302_00
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details
A 15 KW, -1, -2
92
188 49
219 170
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C 30 35 40
170/180 mm 10 bar 10C bis +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3.8 kg 1230 V, 50 Hz 0.10.8 A 0.25 A 8107 W 819 W
137
961302_00
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details
29
Air-conditioning/ Refrigeration
188 49
219 170
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C 30 35 40
180 mm 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 3,8 kg 1230 V, 50 Hz 0.11.25 A 0.14 A 8174 W 819 W
137
max. 10
961302_00
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details
Installation length A 401 KW A 401-1 KW Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C 30 35 40
220 mm 250 mm 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 9 kg 1230 V, 50 Hz 0.11.25 A 0.14 A 8174 W 819 W
18 A 88 max. 10 150
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details
30
L
961303_00
A 500 KW
92
188
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C 30 35 40
220 mm 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 1230 V, 50 Hz 0.11.25 A 0.14 A 8174 W 819 W
50
57
249.2 166.7
125 110
220
165
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details
31
Air-conditioning/ Refrigeration
B1
1/4"
PN 6-16
40
161
14
18 A 402-1 V2 KW
L = 250 mm
961306_00
88 A = 125 mm 150
max. 2m
M20x1.5
B2
116
B1 = 171 mm B2 = 94 mm
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details
A 501 V2 KW
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C max. 40 270 mm 6 16 bar 10C to +95C max. 40C 500 m a.s.l. 0.10 bar 0.65 bar 0.01 bar 20.5 kg 1230 V, 50 Hz 0.251.3 A 0.4 A 35275 W 3065 W
190 50
1/4"
PN 6-16
161
125 110
135
14 18
102 165
270
961307_00
max. 2m
M20x1.5
107
116
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details
32
230
A 502 V2 KW
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C max. 40 270 mm 6 16 bar 10C to +95C max. 40C 500 m a.s.l. 0.20 bar 0.65 bar 0.01 bar 21 kg 1230 V, 50 Hz 0.453.4 A 1A 70720 W 70200 W
190 50
1/4"
PN 6-16
161
125 110
135
14 18
102 165
270
961307_00
max. 2m
M20x1.5
107
116
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details
T1 241 T2 251
B1 65
1/4" PN 6-16
161
961308_01
122 185
max. 2m
M20x1.5
B2
116
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details
33
Air-conditioning/ Refrigeration
230
A 652 V2 KW
Installation length Permissible operating pressure Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C max. 40 340 mm 6 16 bar 10C to +95C max. 40C 500 m a.s.l. 0.35 bar 1.45 bar 0.01 bar 25 kg 1230 V, 50 Hz 0.484.3 A 1A 70930 W 70220 W
207 65
1/4" PN 6-16
161
145 130
340
230
14 18
170
961308_00
122 185
max. 2m
M20x1.5
119
116
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details
A 801 V2 KW
Installation length Permissible operating pressure Special design Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min Ambient temp. C max. 40 360 mm 6 bar 16 bar 10C to +95C max. 40C 500 m a.s.l. 0.35 bar 1.45 bar 0.01 bar 27 kg 1230 V, 50 Hz 0.484.3 A 1A 70930 W 70220 W
371 271
62
251
193 80
PN 6 1/4"
PN 16
150 18
160 18
161
180
360
961393_00
230
128 200
128 200
max. 2m
M20x1.5
107
116
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is provided with fault or operating message (switchable). Optional: Control module, signal module See page 48 for further details
34
A 802 KW
Installation length Permissible operating pressure Special design Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature at 110C water temperature For every 100 m altitude Weight Voltage Current Regulation Power Regulation Ambient temp. C max. 40 360 mm 6 bar 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.6 bar 1.0 bar 1.7 bar 0.01 bar 32 kg 1230 V, 50 Hz 0.59.3 A 501790 W
132
100 80 97
506 409
PN 6 160 150
PN 10 160 18
360
250
961333_00
128 200
18
128 200
196
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection.
A 1002 KW
Installation length Permissible operating pressure Special design Permissible operating temp. Ambient temperature Required operating pressure at at 75C water temperature at 95C water temperature at 110C water temperature For every 100 m altitude Weight Voltage Current Regulation Power Regulation Ambient temp. C max. 40 450 mm 6 bar 10 bar 10C to +95C max. 40C 500 m a.s.l. 0.6 bar 1.0 bar 1.7 bar 0.01 bar 32 kg 1230 V, 50 Hz 0.59.3 A 501790 W
135
530 410
PN 6 170 18
PN 10 180 18
450
250
961347_00
160 220
160 220
196
The pump is suitable for cold water application. The pump is fitted with internal electric motor protection and requires no external motor protection.
35
Air-conditioning/ Refrigeration
36
Twin pumps
AD 401 KW AD 402 V2 KW AD 652 V2 KW AD 802 KW
List of models
DN 40
Type AD 401 KW AD 402-1 V2 KW AD 501 V2 KW, AD 502 V2 KW AD 651 V2 KW, AD 652 V2 KW AD 802 KW
Energy class A A A A A
50 65 80
KW = modified version for cold water application. With special coating resistant to condensed water.
37
Air-conditioning/ Refrigeration
AD 401 KW
AD 401 KW A 401 KW The pumps are designed for individual operation in systems with higher safety requirements (P1 or P2) Parallel operation (P1 + P2) only permitted in constant speed mode (cs) or with external speed setting (0 10 V/0 20 mA) but not in controlled operation mode (cp or pp) Optional: Control module (2 ) Signal module (2 ) Both module types with integral twin pump function 22h / 2h alternating operation
AD 401 KW
236 297 50 174 PN 6-10 110 100
220
14 18
961304_00
88 150
251 B2 T2 B3
B1 B4
1/4"
161
PN 6-16
116 230
k2 k1 14
T3
M20x1.5
L1 L2
L3
18 DN
max. 2m
The pumps are designed for individual operation in systems with higher safety requirements (P1 or P2) Parallel operation (P1 + P2) only permitted in constant speed mode (cs) or with external speed setting (0 10 V/0 20 mA) but not in controlled operation mode (cp or pp) Optional: Control module (2 ) Signal module (2 ) Both module types with integral twin pump function 22h / 2h alternating operation
961309_00
AD 402-1 V2 KW AD 501 V2 KW AD 502 V2 KW AD 651 V2 KW AD 652 V2 KW PN 6-16 DN L1 B1 B2 B3 B4 D k1 (PN 6) k2 (PN 10/16) L2 L3 T1 T2 T3 M 40 250 387 91 72 108 150 100 110 144 112 294 73 219 M 20 1.5 M 16 1.5 kg 35 PN 6-16 50 270 473 102 132 123 165 110 125 124 115 301 83 218 M 20 1.5 M 16 1.5 50 PN 6-16 50 270 473 102 132 123 165 110 125 124 115 301 83 218 M 20 1.5 M 16 1.5 50 PN 6-16 65 340 491 110 130 135 185 130 145 158 152 322 93 220 M 20 1.5 M 16 1.5 60 PN 6-16 65 340 491 110 130 135 185 130 145 158 152 322 93 220 M 20 1.5 M 16 1.5 60
AD 802 KW
479 497 97 400
AD 802 KW
A 802 KW
80
PN 6 150 18
PN 10 160 18
360
Alternating operation, 24h/24h See page 48 for further details Refer to individual pump for technical data
160
250
The pumps are designed for individual operation in systems with higher safety requirements (P1 oder P2)
128
961334_00
128 200
121
120
120
118
200
38
List of models
DN
11/4150 mm
Installation conditions
Optimum spacing of cable box with temperature sensor from hot water heater: 20 to 50 cm Determine spacing from pump to fitting position of cable box with temperature sensor. Draw sensor cable from cable box with the required cable length. The length of the sensor cable is 2.5 m
20-50cm
7 1 6 4
1 Pump 2 Cable box with temperature sensor 3 Sensor cable (2.5 m) 4 Cable binders 5 Hot water heater 6 Return valve (Return flow valve) 7 Ball valve
> 50cm
961227_02
39
Service water
Standard
AXW smart
Experiential smart technology recognises and anticipates your consumption habits to make hot water available Variable comfort setting from maximum energy saving to maximum comfort Legionella protection
Shut-off set Non-return valve and ball valve Types of control (Proportional pressure, contact pressure and constant speed) Fault or operating message (switchable) Power limiting (can be deactivated)
Electrical connection
Pump L N = Lead = Neutral line = PE wire, protective conductor
L N
Options
Sensor cable (5 m) Signal module
Control module
40
961314_00
AXW 10 smart
Installation length 120 mm Permissible operating pressure 10 bar Permissible operating temperature +15C to +65C (for shorts periods max. 85 C for thermal disinfection). To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temperature max. 40 C Water hardness max. 35fH (20dH) Required operating pressure at 500 m a.s.l. at 65C water temperature 0.05 bar at 85C water temperature 0.30 bar For every 100 m altitude 0.01 bar Weight 2.4 kg Voltage 1230 V, 50 Hz Current 0.040.1 A Power 4.78.4 W The pump is fitted with internal electric motor protection and requires no external motor protection. The pump always starts with a high torque. Pump housing: bronze Incl. Shut-off set (Non-return valve and ball valve) See page 49 for further details
124 78 G1"
217
120
G1" max. 10
AXW 12 smart
Installation length 120 mm Permissible operating pressure 10 bar Permissible operating temperature +15C to +65C (for shorts periods max. 85 C for thermal disinfection). To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temperature max. 40 C Water hardness max. 35fH (20dH) Required operating pressure at 500 m a.s.l. at 65C water temperature 0.05 bar at 85C water temperature 0.30 bar For every 100 m altitude 0.01 bar Weight 2.4 kg Voltage 1230 V, 50 Hz Current 0.070.15 A Power 8.719 W The pump is fitted with internal electric motor protection and requires no external motor protection. The pump always starts with a high torque. Pump housing: bronze Incl. Shut-off set (Non-return valve and ball valve) See page 49 for further details
124 78 G1"
217
120
G1" max. 10
961429_00
961429_00
41
Service water
AXW 13 smart
Installation length 150 mm Permissible operating pressure 10 bar Permissible operating temperature +15C to +65C (for shorts periods max. 85 C for thermal disinfection). To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temperature max. 40 C Water hardness max. 35fH (20dH) Required operating pressure at 500 m a.s.l. at 65C water temperature 0.05 bar at 85C water temperature 0.30 bar For every 100 m altitude 0.01 bar Weight 2.6 kg Voltage 1230 V, 50 Hz Current 0.120.3 A Power 14.332.7 W The pump is fitted with internal electric motor protection and requires no external motor protection. The pump always starts with a high torque. Pump housing: bronze Incl. Shut-off set (Non-return valve and ball valve) See page 49 for further details
124 78 G1"
247
150
G1" max. 10
AXW 14 smart
Installation length 150 mm Permissible operating pressure 10 bar Permissible operating temperature +15C to +65C (for shorts periods max. 85 C for thermal disinfection). To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temperature max. 40 C Water hardness max. 35fH (20dH) Required operating pressure at 500 m a.s.l. at 65C water temperature 0.05 bar at 85C water temperature 0.30 bar For every 100 m altitude 0.01 bar Weight 2.6 kg Voltage 1230 V, 50 Hz Current 0.280.38 A Power 3245 W The pump is fitted with internal electric motor protection and requires no external motor protection. The pump always starts with a high torque. Pump housing: bronze Incl. Shut-off set (Non-return valve and ball valve) See page 49 for further details
124 78 G1"
247
150
G1" max. 10
42
961430_00
961430_00
List of models
DN
40
40
40250 mm
AW 402-1 V2
PN 6 16
43
Service water
Standard
AW 15 AW 401 8 174 W
AW 402 V2 25 420 W
Experiential smart technology recognises and anticipates your consumption habits to make hot water available Variable comfort setting from maximum energy saving to maximum comfort Legionella protection
Shut-off set Non-return valve and ball valve Types of control (Proportional pressure, contact pressure and constant speed) Fault or operating message (switchable) Power limiting (can be deactivated)
Electrical connection
961192_00
N L
Supply 1 230 V Back-up fuse 10 A
N L
Supply 1 230 V Back-up fuse 10 A
L N
51-54 fault or operating message (switchable) as NO contact: closes for fault/operation Contact loading max. 250 V~, 1 A 51-52 fault or operating message (switchable) as NC contact: opens for fault/operation Contact loading max. 250 V~, 1 A
961191_00
54 52 51
max. 250 V 1A
54 52 51
max. 250 V 1A
Options
Signal module See page 48 for further details Control module See page 48 for further details Thermal insulation shells
44
961191_00
961301_00
124 78 G1"
L1 G1"
961431_00
Required operating pressure at at 75C water temperature at 85C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min
max. 10
H [kPa]
ma x
H [m]
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 85 30 30 85 35 35 85 40 40 70 The pump is fitted with internal electric motor protection and requires no external motor protection. Pump housing: bronze AXW 12: incl. shut-off set AXW 12-1: Shut-off set not available
min
P [W] 1
max
min
961151_00
124 78 G1"
L1 G1"
961431_00
Required operating pressure at at 75C water temperature at 85C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min
max. 10
0 20 ft 16 12 30 8 4 0 20 10 0 0 60 P [W] 1 40 20 0 0 H0 [kPa] 50 40
1 0.6
2 1.2
m ax
The pump is fitted with internal electric motor protection and requires no external motor protection. Pump housing: bronze AXW 13: incl. shut-off set AXW 13-1: Shut-off set not available
min
961158_00
10
12
14
imp.g.p.m 20
45
Service water
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 85 30 30 85 35 35 85 40 40 70
min
0.5 1 1.5 2 2.5
max
AW 15-2
92
188 49
201 152
Installation length Permissible operating pressure Permissible operating temp. Permissible water hardness
Required operating pressure at at 75C water temperature at 85C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min
180 mm 10 bar +15C to +85C 65C (max. 35fH = 20dH) 85C (max. 25fH = 14dH) 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 4.2 kg 1230 V, 50 Hz 0.10.8 A 0.25 A 8107 W 819 W
961432_00
180
max. 10 2"
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 85 30 30 85 35 35 85 40 40 70 The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is fitted with fault or ready indication (switchable). Pump housing: bronze
1) As delivered with power limiting
AW 401-1
Installation length Permissible operating pressure Permissible operating temp. Permissible water hardness 250 mm 10 bar +15C to +85C 65C (max. 35fH = 20dH) 85C (max. 25fH = 14dH) 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 1230 V, 50 Hz 0.11.25 A 0.14 A 8174 W 819 W
137
125
150
Required operating pressure at at 75C water temperature at 85C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 85 30 30 85 35 35 85 40 40 70 The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is fitted with fault or ready indication (switchable). Pump housing: bronze
1) As delivered with power limiting
46
AW 402-1 V2
Installation length Permissible operating pressure Permissible operating temp. Permissible water hardness 250 mm 10 bar +15C to +85C 65C (max. 35fH = 20dH) 85C (max. 25fH = 14dH) 500 m a.s.l. 0.10 bar 0.55 bar 0.01 bar 1230 V, 50 Hz 0.252 A 0.33 A 25420 W 3065 W
354 279 61
151 40 1/4"
110
220
961433_00
88 84 160 150
Required operating pressure at at 75C water temperature at 85C water temperature For every 100 m altitude Weight Voltage Current Regulation min Power Regulation min
M20x1.5
M16x15
To avoid the formation of condensation the media temperature must always be higher than the ambient temperature. Ambient temp. Media temperature C min. C max. C 15 15 85 30 30 85 35 35 85 40 40 70 The pump is fitted with internal electric motor protection and requires no external motor protection. The pump is fitted with fault or ready indication (switchable). Pump housing: bronze
1) As delivered with power limiting
47
Service water
Options
Signal module
Signal module
Extension for the following auxiliary functions/interfaces: External operating indication External ON/OFF External switching of minimum speed Interface for twin pumps function Note: Not possible in combination with control module
961267_00
961178_00
13 11 10 91 92
64 62 61
Connection diagram 10-11 control contact for switching pump on and off externally 10-13 control contact for switching minimum speed on and off externally 61-64 operating or ready message (NO contact) 61-62 operating or ready message (NC contact) 91-92 twin pump
Control module
Control module
Extension for the following auxiliary functions/interfaces: Speed adjustment via analogue interface (0 10 V or 0 20 mA) External ON/OFF Multitherm or PWM interface Interface for twin pumps function
961267_00
Note: Not possible in combination with signal module Connection diagram 10-11 control contact for switching pump on and off externally 81-82 Multitherm/PWM interface 71-72 analogue input 010 V or 020 mA for external speed setting 91-92 twin pump
961177_00
81 82 71 72 11 10 91 92
B
T1
961194_00
Pump type AX 12, AX 12-1, AX 12-2 AX 13, AX 13-1, AX 13-2 AXW 12-1, AXW 13-1 A 12, A 12-1, A 12-2 A 13, A 13-1, A 13-2 A 14, A 14-1, A 14-2 A 15, A 15-1, A 15-2 A 16-1, A 16-2 AW 15-2 A 401, A 401-1, AW 401-1 A 402 V2 A 402-1 V2, AW 402-1 V2 A 500 A 501 V2, A 502 V2 A 651 V2, A 652 V2 A 651-1 V2 A 801 V2 A 802 A 1002
1)
Type WD 1 1)
B 140
B1 70
H 140
T 90
T1 50
WD 2
150
75
140
108
70
WD 3 WD 4 WD 5 WD 11 WD 6 WD 7 WD 12 WD 8 WD 9 WD 10
150 210 230 167 260 280 240 280 300 320
178 179 209 174 225 293 222 310 310 395
140 154 154 151 174 185 183 214 200 225
48
Options
Construction set for offset electronics installation
Media temperature: up to 110 C Ambient temperature: max. 40 C Pump can be insulated up to 100 C medium temperature Note: If condensation forms (medium temperature lower than ambient temperature) it is recommended to use the cold water version (KW) with coating resistant to condensation.
116 161
max. 2m
Ball valve
Non-return valve
53 40
961221_00
230
G 1 1/4"
961396_00
961395_00
Material: Brass
G 1 1/4"
G 1"
G 1"
Biral AG Sdstrasse 10 CH-3110 Mnsingen T +41 (0) 31 720 90 00 F +41 (0) 31 720 94 42 E-Mail: info@biral.ch www.biral.ch
Biral GmbH Przisionspumpen Freiherr-vom-Stein-Weg 15 D-72108 Rottenburg am Neckar T +49 (0) 7472 16 33 0 F +49 (0) 7472 16 34 0 E-Mail: info@biral.de www.biral.de
Biral Pompen B.V Printerweg 13 3821 AP Postbus 2650 3800 GE NL-Amersfoort T +31 (0) 33 455 94 44 F +31 (0) 33 455 96 10 E-Mail: info@biral.nl www.biral.nl