Features
G Quick and simple installation and maintenance G Extended spigot connections G 100% opening capacity G Low noise generation G Air tightness to DW144 Class C G Linear choking for simple operation G High accuracy and excellent adjustment properties
Quick, silent and efficient is the simple summary of the features of the Actionair Iris Control Damper (ICD) for the adjustment and measuring of airflow.
Function The Actionair ICD is an iris damper for measuring and adjusting the air flow. The ICD has the following specifications: low noise level, centrically-formed air flow and fixed test points for precise measurements. The damper also has an adjustment aperture which can be opened completely. Available in sizes 100 to 630mm diameters. Maximum temperature for ICD is 70 C. Design The damper is manufactured from galvanised sheet steel and is fitted with a rubber seal tested for air-tightness. Exhaust ventilation Using the ICD damper for exhaust Ventilation by diffusion offer many advantages over other forms 2 www.actionair.co.uk
of ventilation and one of them is the simplicity in design and layout of exhaust air. The dynamics of an extracted air flow is independent of geometry and direction at all distances greater than a couple of diameters from the opening. As long as the extracted air volume equals the supply air volume it doesn't matter where the extract opening is located nor does the number of openings applied. When you are using dampers with good control abilities and enough pressure drop like ICD, these can be combined with a supply diffuser to form functional exhaust installations. By using the same diffuser for supply and exhaust you can achieve an aesthetic ceiling profile.
Mounting The ICD adjustment damper must be installed in accordance with the distances required to minimise air-flow deviation. The ICD enables the taking of precise air-flow measurements at all points including points close to duct deviations such as T junctions and bends and points in front of other supply air devices. Protective distance before bends 1 x Diameter. after bends 1 x Diameter. before T-pipes 3 x Diameter. after T-pipes 1 x Diameter. before supply-air devices 3 x Diameter.
Specification Actionair ICD The Actionair ICD Iris Control damper, housed in a galvanised sheet steel casing with circular extended spigots for ease of duct connection. The simplicity of the Actionair ICD design with linear choking, provides quick and efficient airflow adjustment and measurement with low noise generation. Note: Maximum damper differential pressure is as indicated on Performance Data charts, pages 4, 5 and 6.
Dimensions
60
20
60
ICD Size d
30
54 63 54 60 62 62 63 70 60 60
163 210 230 230 285 333 406 560 644 811
XSGR05111 10.00
40
40
The compact measurements of the Actionair ICD, are an advantage as space is often limited. www.actionair.co.uk 3
Performance Data
100
0 250 Pt [Pa] 55dB(A) 200 50 150 45 150 100 40 35 50 30 30 0 10 20 30 40 35 0 50 60 70 80 90 I/s 0 50 30 100 40 45 50 55 100 50 45 40 35 30 35 40 150 45 50 Pt [Pa] 50 100 150 200 250 300 m3/h 300 250 300 50
160
0 200 55dB(A) 400 600 800 m3/h
55
200
250 I/s
125
0 400 Pt [Pa] 55dB(A) 350 300 250 200 150 100 50 0 0 20 40 30 50 100 200 300 400 500 m3/h Pt [Pa] 200 180 160 140 120 45 40 35 30 40 35 80 100 120 140 I/s 55 50 45 100 80 60 40 20 0
200
54 200 400 600 800 1000 1200 1400 m3/h
55dB(A)
50 45 40 35 30 50 35 15 65 115 165 40 45 55
60
150
0 350 Pt [Pa] 300 250 50 200 150 100 50 0 0 50 45 40 35 30 35 40 45 55 100 150 55dB(A) 200 400 600 800 m3/h 250 Pt [Pa]
250
0 500 55dB(A) 200 50 45 40 35 30 50 30 35 0 200 250 I/s 0 100 200 300 400 500 600 I/s 40 45 50 50 55 1000 1500 2000 m3/h
30 100
150
www.actionair.co.uk
Performance Data
315
0 180 Pt [Pa] 160 140 120 100 80 60 40 20 0 0 30 35 35 30 45 40 0 0 200 400 600 30 35 40 50 55 50 45 50 500 55dB(A) 50 45 40 100 1000 1500 2000 2500 3000 m3/h 250 Pt [Pa]
500
0 1000 55dB(A) 2000 3000 4000 5000 m3/h
200
45 40 35 30
150
100 200 300 400 500 600 700 800 900 I/s
400
0 300 Pt [Pa] 250 200 150 100 50 0 0 Pt [Pa] 55dB(A) 1000 2000 3000 4000 5000 m3/h 250
630
0 2000 55dB(A) 200 45 150 40 100 35 50 30 35 40 45 50 55 0 0 500 1000 30 30 40 1500 2000 45 4000 6000 8000 10000 m3/h
30 30 30 30 30
50
Ordering Information
Example Quantity 10 Size 100 Description ICD PART No. XSGR05101
www.actionair.co.uk
Dimensions
60
30
20
60
d D
40
40
The compact measurements of the Actionair ISD, are an advantage as space is often limited.
C 60 62 62 63 70
www.actionair.co.uk
Performance Data
SPM 160 0 140 Pt [Pa]
Pt [Pa]
SPM 315 100 200 300 400 500 m3/h 200 45 180 160 140 120 100 0 200 400 600 800 1000 1200 1400 1600 1800 m3/h
120
45 40
100 80
60 45 40 35 20 30 25dB(A) 40
80 60 40 20 0 25 0 50 30 35 40 dB(A) l/s 45
SPM 200
0 120 Pt [Pa] Pt [Pa] 45 100 40 80 35 60 100 30 40 40 20 30 25dB(A) 0 0 20 40 60 80 100 120 140 160 180 200 l/s 0 35 45 50 150 200 100 200 300 400 500 600 700 m3m
45
40
35 30 25
dB(A) 0 100 200 300 400 500 600 700 800 900 l/s
SPM 250 0 140 Pt [Pa] 200 400 600 800 1000 1200 1400 1600 m3/h
120
100
80 60
Ordering Information
45dB(A)
40
40
300
350
400
450 l/s
www.actionair.co.uk
Options
Actionair ICD-M (Motorised) Where the ventilation requirements are variable, dependent on say temperature or CO2 , the Actionair ICD-M, motorised unit may be used.The motor will receive a signal from the installed sensor and vary the air supply accordingly. The maximum/minimum opening position can be adjusted manually using the release button on the unit. Once set the damper will return to automatic operation.
ICD-M 24V On/Off Part Number Weight Kg Size 100 125 160 200 250 315 NM24A NM24A NM24A NM24A SM24A SM24A XSGR05113 XSGR05116 XSGR05119 XSGR05122 XSGR05125 XSGR05128 2.20 2.50 3.20 4.00 4.95 5.20
Motor Options 240V On/Off NM230A NM230A NM230A NM230A SM230A SM230A Part Number Weight Kg 24V Modulating Part Number Weight Kg On/Off NM24A-SR NM24A-SR NM24A-SR NM24A-SR SM24A-SR SM24A-SR XSGR05115 XSGR05118 XSGR05121 XSGR05124 XSGR05127 XSGR05130 2.20 2.50 3.00 3.20 3.50 3.80
Ordering Information
Example Quantity 10 Size 100 Description ICD-M Motor Option NM24A-SR PART No. XSGR05115
www.actionair.co.uk
Actionair ISD-M (Motorised) Where the ventilation requirements are variable, dependant on say temperature or CO2, and complete closing is required, the Actionair ISD-M motorised unit may be used. The motor will receive a signal from the installed sensor and vary the air supply accordingly. The maximum/minimum opening position can be adjusted manually using the release button on the unit. Once set the damper will return to automatic operation. When using the Actionair ISD-M we recommend the installation of the Actionair CDS Access Door with the unit.
ICD-M 24V On/Off Part Number Weight Kg Size 160 200 250 315 NM24A NM24A SM24A SM24A XSGR05137 XSGR05140 XSGR05143 XSGR05146 2.40 3.90 5.80 7.80
Motor Options 240V On/Off NM230A NM230A SM230A SM230A Part Number Weight Kg 24V Modulating Part Number Weight Kg On/Off NM24A-SR NM24A-SR SM24A-SR SM24A-SR XSGR05139 XSGR05142 XSGR05145 XSGR05148 3.40 4.30 5.80 7.80
Ordering Information
Example Quantity 10 Size 160 Description ISD-M Motor Option NM24A-SR PART No. XSGR05139
www.actionair.co.uk
Accessories
40
Actionair MR Constant Airflow Device The Actionair MR Constant airflow device housed in a galvanised sheet steel casing with silicon bellows with a polycarbonate centre, dimensioned so as to maintain a constant air volume. The Actionair MR can be vertically or horizontally mounted, either within an Actionair Access/Shield CDS access door or spiral ductwork. For use with air volumes up to 200 l/s. Operating temperatures 30 to +60 C Adjustment is made by setting dividers into 1 of 10 different positions.
10
www.actionair.co.uk
Accessories
Actionair AccessShield CDS The access door can be easily opened without tools. The door is fitted with a sealing gasket. Manufacture is from galvanised mild steel and is available in sizes 100mm diameter to 400mm.
40
40
Ordering Information
Example Quantity 10 Size 100 Description CDS PART No. XSGQ05155
www.actionair.co.uk
11
Ruskin Air Management Limited is a ISO 9001 and 14001 registered company.
The statements made in this brochure or by our representatives in consequence of any enquiries arising out of this document are given for information purposes only. They are not intended to have any legal effect and the company is not to be regarded as bound thereby. The company will only accept obligations which are expressly negotiated for and agreed and incorporated into a written agreement made with its customers. Due to a policy of continuous product development the specification and details contained herein are subject to alteration without prior notice.