Professional Documents
Culture Documents
Contents
1. 2.
KNG-AM1C 155M Access MSPP KNG-AM1S 155M Access MSPP KNG-AM1 155M/622M Access MSPP KNG-AM16E 622M/2.5G Access MSPP KNG-AM16 2.5G Access/Core MSPP KNG-OFC Otic Fiber Converter KNG-DS3X DS3 Circuit Repeater
3.
4. 5. 6. 6 7.
Summary of KNG-AM products Operating Terminal (EMS) Detailed view of KNG-AM1 (RN platform) Detailed view of KNG-AM16 (AN/BN/CN platform)
Introduction of MSPP
Why MSPP ?
Service Provider
Over-Provision of TDM network Low Profit from TDM services Need a low CAPEX/OPEX
Customer
Premium Data Services
MultiMulti-Service Provisioning Platform (MSPP) provides the services of multiple network elements in a single platform. KNGKNG-AM platforms provide TDM solutions p p with interfaces such as DS-1/1E/3, DSand DATA solutions with FE/GE Ethernet interfaces at the STM-1/4/16 optical transport rates STMToward a Leading Wireless & Wire Internet Access Solution Provider
Introduction of MSPP
What is Benefit ?
50ms Restoration after a Line/Equipments defect Line/Equipment s Sharing Voice and Data traffic on One Fiber Connect Ethernet interface Equipment without CSU/DSU Flexible Data Bandwidth which is a multiple of 1Mbps VC-level isolated Leased Line services VLAN/MPLS l b l i l t d Vi t l L label isolated Virtual Leased Li services d Line i Unified Network Management
Introduction of MSPP
MSPP
Voice Equipment
E1/T1 Ethernet
SONET/SDH MUX
MSPP
SONET/SDH SO /S
Router CSU/DSU
E1/T1 E3/T3
Router Switch
SONET/SDH SO /S
Ethernet
Data Channel Rate is fixed, 2Mbps or 45Mbps y (PPP/HDLC) ) Lower Channel Efficiency ( Dedicated Data Service Leased Line hard to Expand their bandwidth Private Data Network Layer-3 level Router-to-Router Complex to Operate and Maintain
Data Channel Rate is the Multiple of 1Mbps g y (GFP) ) Higher Channel Efficiency ( Dedicated/Shared Data Service Leased Line Shared Line : Over-Subscription Private Data Network Layer-2 or Layer-3 level Switch/Router-to-Switch/Router connection Easy to Operate and Maintain
Introduction of MSPP
MSPP Networks
Various Access/Core Networks
Proven Standards Point-to-Point and Linear connection Ring and Ring-to-Hub connection Multiple and Subtending Ring
155M/622M/2.5G 155M/622M/2.5G
UNIVERSITY
Introduction of MSPP
MSPP
MSPP
Voice Equipment
E1/T1 Ethernet
SONET/SDH
Router Switch
Ethernet
Router Switch
Voice
VC map VC12 VC12 VC12 GFP/ LAPS VCAT
Voice
SDH
SDH
VC map
LAN #1 #
LAN #1
VCAT GFP/ LAPS
LAN #2
LAN #2
LCAS
Virtual Concatenation
GFP/LAPS
ITU-T G.7041 Encapsulation of Ethernet frame and Raw data ATM-like ATM like encapsulation The highest Utilization of Bandwidth
LCAS
Introduction of MSPP
Introduction of MSPP
Introduction of MSPP
10
Introduction of KNG-AM
Interfaces I t f
PDH : 84 DS1, 63 DS1E, 3 DS3 SDH : 4 STM1 Ethernet : 8 FE
Toward a Leading Wireless & Wire Internet Access Solution Provider Proprietary of Kisan Telecom 11
Introduction of KNG-AM
Other Company
Chip-C Yes (3) 16 bit Intel/Mot 1.3 W 324 PBGA 1.0 W 376 PBGA 2.5 W 400 PBGA Chip-D Yes (28, 28) Chip-E Yes Yes Y Yes Yes (8 SMII) LAN S/W Yes Yes Yes 2W
Ethernet Switch
12
Introduction of KNG-AM
Equipment
Hot H t swappable S it hi & Li I t f bl Switching Line Interface unit it 19 standard rack mountable & Standalone
Topology
P-to-P, Ring, Ring-Hub, Multi/Subtending-Ring P to P Ring Ring Hub Multi/Subtending Ring Topology MSP, SNCP, MS-SPRing Protection
Ethernet-over-SDH
IEEE802.1Q QoS QQ Port/VLAN-base Rate Limiting Q-in-Q, Jumbo Frame LLCF, Link Aggregation Ethernet Private Line service Eth t P i t Li i Ethernet Virtual Private Line Service
Management platform
GUI base GUI-base user interface Remote management via IP & DCC channels
Toward a Leading Wireless & Wire Internet Access Solution Provider Proprietary of Kisan Telecom 13
KNG-AM MSPP
KNG-AM16
KNG-AM16E
KNG-AM1C
Compact & Low cost Wireline Access Wireless Backhaul
Customer
Access/Edge g
Core
14
Introduction of KNG-AM
KNG-AM1C
155Mbps Access MSPP p
19 rack mountable, 1U height Pizza-box AC 220V, DC -48V
Ethernet services
8 EoS (Ethernet over SONET) channel, Private/Virtual private Line service QoS control Q in Q, Q-in-Q, Jumbo Frame Rate Limiting per 1Mbps LLCF (Link Loss Carrier Forward)
15
Introduction of KNG-AM
KNG-AM1S
155Mbps Access MSPP p
19 rack mountable, 1U height Pizza-box AC 220V, DC -48V Redundant Power
AM1S-to-AM1S stacking
Doubling the Subscribers port
Ethernet services
8 EoS (Ethernet over SONET) channel Private/Virtual private Line service channel, QoS control Q-in-Q, Jumbo Frame Rate Limiting per 1Mbps LLCF (Link Loss Carrier Forward)
16
Introduction of KNG-AM
KNG-AM1
155M/622Mbps Access MSPP p
19 rack mountable, 2U height Shelf AC 220V, DC -48V Redundant Power
Ethernet services
16 EoS (Ethernet over SONET) channel, Private/Virtual private Line service QoS control Q-in-Q, Jumbo Frame Rate Limiting per 1Mbps LLCF (Link Loss Carrier Forward)
17
Introduction of KNG-AM
KNG-AM16E
622M/2.5Gbps Access MSPP p
19 rack mountable, 3U height Shelf AC 220V, DC -48V Redundant Power
PSU-D
ACT FAIL
PSU-D
A CT F AIL
D3U
ACT FAIL LF 1 LF 2 LF 3
D3U
A CT F AIL L F1 L F2 L F3
D1U
A CT F AIL
D 1U
ACT FAIL
S1U
A CT F AIL
ACT
S1U
ACT FAIL
ACT SF P1 P2 P3 P4
S1U
A CT F AIL
ACT SF P 1 P2 P3 P 4
S1U
ACT FAIL
ACT SF P1 P2 P3 P4
S16U
AC T F AIL IN T EXT LP HL D
S16U
A CT F AIL INT EXT LP H LD
FEU
A CT F AIL
GEU
A CT F AIL
DVU
ACT FAIL LF
EMCU
ACT F AIL CR MJ MN HIS ACO
SF P 1 P2 P3 P4
FE
1/ 2 ACO
P1
P1
P1
P1
LDTST 3/ 4 RST LINK
ON
ON L21~ 24
P2 P2 P2 P2
ACT/SF ACT/S F
D VB-ASI
5/6
CIT
P3
P3
P3
P3
ACT/SF ACT/ SF 7/ 8 LI NK
P4
P4
P4
P4
EMS
Ethernet services
32 EoS (Ethernet over SONET) channel, Private/Virtual private Line service QoS control Q-in-Q, Jumbo Frame Rate Limiting per 1Mbps LLCF (Link Loss Carrier Forward)
Toward a Leading Wireless & Wire Internet Access Solution Provider Proprietary of Kisan Telecom 18
Introduction of KNG-AM
KNG-AM16
2.5Gbps Access/Core MSPP p
19 rack mountable, 7U height Shelf DC -48V Redundant Power
Ethernet services
48 EoS (Ethernet over SONET) channel, Private/Virtual Private Line Service QoS Control Q-in-Q, Jumbo Frame Rate Limiting per 1Mbps LLCF (Link Loss Carrier Forward)
Toward a Leading Wireless & Wire Internet Access Solution Provider Proprietary of Kisan Telecom 19
KNG-OFC
Main Functions
Repeater : Optic Repeater for Long-haul section (3R)
Re-Amplification Re-Timing Re-Shaping
Wavelength Converter : Change a distance and Wavelength Reduction of Optic Core : by using Bi-Di Transceiver
Features
Number of Channels Fiber Interface Signal Regeneration Data Rate Management (Config.) g ( g) Power Supply Mechanical 2 Converter/Repeater 4 SFP Transceiver 3R (Re-shaping, Re-timing, Re-amplification) OC-48, OC-12, OC-3, Gigabit Ethernet DIP-switch, House-keeping p ( p LoS, Power FAIL) , p g port (Optic , ) 2 x -48V DC or 2 x 100~240V AC 19 1U, 440(W) x 44(H) x 300(D)
OFC Repea t e r SDH SDH
15Km, 1310nm
OFC
120Km, 1490/1550nm
Bi-Di Transceiver
15Km, 1310nm
SDH
20
KNG-DS3X
Main Functions
Total 4 x DS-3 Line interfaces Unit and Line based 1+1 protection Protection By Push-button in front of system Automatic switching while detecting an Line or Unit Error Manual switching by user command Management RS-232/LAN interface Performance Monitoring : BPV, SES, UAS Manual S it hi and L k mode M l Switching d Lock d
D3XU
D3XU
D3XU
D3XU
DMCU
SPD
LAN
PSU-2
PSU-1
IO-2
IO-1
FG
ACH
ACN
FG
-48V
GND
IN-1
IN-2
CROSS
OUT-1
OUT-2
IN-1
IN-2
CROSS
OUT-1
OUT-2
ACT D3XU-IO
NORMAL
D3XU-IO
NORMAL
Features
Number of Channels Management (Config.) Power Supply Mechanical 4 DS3 Input, 4 DS3 Output RS-232, LAN (Telnet) 2 x -48V DC or 2 x 100~240V AC 48V 19 1U, 440(W) x 44(H) x 300(D)
DS3 Network
DS3 lines
D3XU D3XU
DS3
D3XU D3XU DMCU
DS3 lines
LINK SPD RESET RS-232
DMCU
LAN
DS3 Network
21
KNG-AM1S
44(H) x 440(W) x 300(D)
KNG-AM1
88(H) x 435(W) x 300(D)
KNG-AM16E
132(H) x 435(W) x 300(D)
KNG-AM16
311(H) x 435(W) x 300(D)
AC220V/DC-48V 8 8 3 1 8 -
AC220V/DC-48V 16 16 3 1 8 -
AC220V/DC-48V 72 63 3 1, 2 1 8 -
Ethernet Services
22
EMS
EMS
User friendly GUI Interface friendl Operation, Administration, Maintenance & Provision Real time Real-time Alarm Report Scheduled Performance Report Remote Download Remote control via DCC channel TL1, SNMP Interface PC-based PC based Platform
23
24
KNG-AM1
Layout - Front
PSU D3U D1U
2
ACT FAIL SF1 SF2 INT EXT HLD LP
OTU2
2
ACT FAIL SF1 SF2 INT EXT HLD LP
OEU/FBU
RMCU
P1
P1
P2
P2
- Power - 1+1
- DS3/DS1E - 1:1
- DS3/DS1E - N:1
- EoS
- Controller - LAN/RS232
25
KNG-AM1
Layout - Rear
MSC-IO EOU-IO EIU-IO CLK-IO D1U-IO D3U-IO PSU-IO ALM-IO
OUT
IN
OUT
IN
OUT
IN
OUT
IN
- Alarm - EMS
- 100BaseTx
- Power terminal
26
KNG-AM1
27
KNG-AM1
KNG-AM1
Units
Board RMCU OTU OTU2 OEU FBU D3U D1U PSU-A PSU-D MSC-IO ALM-IO EIU-IO EOU-IO EIU-IO2 EIU IO2 CLK-IO D1U-IO D D3U-IO O PSU-IO Description Main Controller, CIT interface 311M Switching capacity, 1xSTM-1 line interface, System Clock 622M Switching capacity, 2xSTM-1 line interface, System Clock Ethernet-over-Sonet, 16 E S channel, 8 port LAN s it h Eth t S t EoS h l t switch FAN Unit 1 x DS3 Line Interface Unit 8 x DS1/1E Line Interface Unit Power supply, AC input (110~220V) Power supply, DC input (-48V) House keeping(4 port in/out) Alarm interface(External PDP), EMS interface 4 x 100BaseTx, RJ45 Interface 4 x 100BaseFx, SFP Optic module 8 x 100B 100BaseTx, 8 port LAN switch T t it h External Clock, RS232, 2 port In/Out 8 x DS1/1E Line, 44-pin D-SUB interface 1 x DS3 L n , BNC interface DS Line, N nt rfac AC or DC Power terminal RMCU OTU_A, OUT_B OTU_A, OUT_B OEU FBU LIU_1/2, LIU_4/5, LIU_7/8 _ , _ LIU_1/2/3/4/5/6/7/8/9, LIU_P PSU_A, PSU_B PSU_A, PSU_B MSC_IO(Rear) ALM_IO(Rear) EIU_IO1, EIU_IO2 EIU_IO1, EIU_IO2 EIU_IO1, EIU IO2 EIU IO1 EIU_IO2 CLK_IO LIU_1/2/3/4/5/6/7/8/9(Rear) L LIU_1, LIU_4, LIU_7 ,L ,L 7 PSU-IO1, PSU-IO2 Slot Max 1 2 2 1 1 6 10 2 2 1 1 2 2 1 1 9 3 2
29
KNG-AM1
RMCU
System initialization y Provisioning Alarm report DCC channel control System error monitoring
Panel ACT FAIL HIS ACO CR MJ MN ACO LDTST RST CIT LED LED LED LED LED LED LED 3-Pole 3 Pole Switch Push button Push button RS-232 (9-pin) Type Color GREEN RED YELLOW YELLOW RED RED YELLOW System fail Alarm history ALARM-CUT-OFF CRITICAL alarm MAJOR alarm MINOR alarm ALARM-CUT-OFF ALARM CUT OFF LED ON/OFF test System initialization CIT interface Function Normal operation
30
KNG-AM1
OTU
311Mbps non-blocking switching 1 port STM-1 optical line interface SFF (Small Form Factor) type optic transceiver : 15Km, 40Km P-to-P, SNCP Ring 1+1 Protection Reference clock generation
Panel ACT FAIL SF EXT E LP HLD LED LED LED LED E LED LED
Type yp
Color GREEN RED RED GREEN G EE GREEN YELLOW Normal operation Board Fail STM-1 signal Fail External Clock E l l k
Function
31
KNG-AM1
OTU2
622Mbps non-blocking switching 2 ports STM-1 optical line interface SFF (Small Form Factor) type optic transceiver : 15Km, 40Km P-to-P, SNCP Ring 1+1 Protection Reference clock generation
Panel
2
ACT FAIL SF1 SF2 INT EXT HLD LP
Color GREEN RED RED RED E GREEN GREEN GREEN YELLOW Normal operation Board Fail
Function
P1 port STM-1 signal Fail P2 P port STM-1 signal F l 1 l Fail Internal Clock External Clock p STM-1 line loop Clock HOLD-OVER mode
P1
P2
32
KNG-AM1
OEU
EOS(Ethernet over SONET/SDH) service with 155Mbps channel capacity ( ) p p y 16 VCGs (Virtual Concatenation Groups) 8 x 10/100BaseTx or 8 x 100BaseFx Ethernet interface
Type LED LED LED LED LED LED LED LED LED LED LED
Color GREEN RED RED GREEN GREEN GREEN GREEN GREEN GREEN GREEN GREEN Normal Operation Board Fail Error on EoS channel
Function
Link Status & Activity of Ethernet port 1 Link Status & Activity of Ethernet port 2 Link Status & Activity of Ethernet port 3 Link Status & Activity of Ethernet port 4 Link Status & Activity of Ethernet port 5 Link Status & Activity of Ethernet port 6 Link Status & Activity of Ethernet port 7 Link Status & Activity of Ethernet port 8
33
KNG-AM1
D3U
1 port DS-3 Line interface 1:1 Equipment Protection
34
KNG-AM1
D1U
8 x DS-1 line interface or 7 x DS-1E line interface Selectable between DS-1 and DS-1E by four ports N:1 Equipment Protection (N=9)
Function Normal & Active status Board Fail DS-1/1E Line Fail
35
KNG-AM1
PSU-A
220V AC input p AC/DC power conversion 70W power supply Error/Alarm report
36
KNG-AM1
PSU-D
-48V DC input p DC/DC power conversion 70W power supply Error/Alarm report
37
KNG-AM1
MSC-IO
Housekeeping signal interface : 4 input and 4 output p p g g p p ports External rectifier interface
38
KNG-AM1
ALM-IO
System alarm ( y (audible, critical, major, minor) interface , , j , ) LAN connection with EMS terminal
Type yp 2x5 Ribbon connector RJ-45 connector RJ-45 connector Alarm interface
Function
39
KNG-AM1
EIU-IO
4 ports 10/100BaseTx interface UTP5 cable, RJ45 connector
Panel P1 P2 P3 P4
Function LAN port #1 (Slot #1), LAN port #5 (Slot #2) LAN port #2 (Slot #1), LAN port #6 (Slot #2) LAN port #3 (Slot #1), LAN port #7 (Slot #2) LAN port #4 ( l #1) LAN port #8 (Slot #2) (Slot #1), # ( l # )
40
KNG-AM1
EIU-IO2
8 ports 10/100BaseTx interface UTP5 cable, RJ45 connector
Panel
2
Type yp RJ-45 connector RJ-45 connector RJ-45 connector RJ-45 connector 4 RJ-45 connector RJ-45 connector RJ-45 connector RJ-45 connector
Function LAN port #1 (Slot #1), LAN port #5 (Slot #2) LAN port #2 (Slot #1), LAN port #6 (Slot #2) LAN port #3 (Slot #1), LAN port #7 (Slot #2) LAN port #4 ( l #1) LAN port #8 (Slot #2) (Slot #1), # ( l # ) LAN port #5 (Slot #1), LAN port #9 (Slot #2) LAN port #6 (Slot #1), LAN port #10 (Slot #2) p p LAN port #7 (Slot #1), LAN port #11 (Slot #2) LAN port #8 (Slot #1), LAN port #12 (Slot #2)
41
KNG-AM1
EOU-IO
4 ports 100BaseFx interface SFP module, LC-type connector
Panel
IN
Type yp SFP Optic module SFP Optic module SFP Optic module SFP Optic module FP d l
Function LAN port #1 (Slot #1), LAN port #5 (Slot #2) LAN port #2 (Slot #1), LAN port #6 (Slot #2) LAN port #3 (Slot #1), LAN port #7 (Slot #2) LAN port #4 ( l #1) LAN port #8 (Slot #2) (Slot #1), # ( l # )
P1 P2 P3 P4
OUT
IN
OUT
IN
OUT
I IN
OUT
42
KNG-AM1
CLK-IO
2.048MHz reference clock connection 2 clock Input and 2 clock Output
Panel EXT-CLK
43
KNG-AM1
D1U-IO
8 x DS-1/1E twisted pair copper cable connection p pp Selectable between DS-1 and DS-1E by four ports 100 ohm termination for DS-1 and 120 ohm termination for DS-1E interface 44-pin D-SUB connector
Panel LINE-INTF
44
KNG-AM1
D3U-IO
1 port DS-3 coaxial cable connection p 75 ohm termination BNC connector
Panel IN OUT
45
KNG-AM1
PSU-IO
AC Power input terminal DC Power input terminal
Type yp Input Terminal Input Terminal Input Terminal Input Terminal l Input Terminal -48V Ground AC Positive -48V AC Negative Frame Ground
Function
46
KNG-AM1
Protection - Power
Equipment Protection Load sharing scheme Monitoring power Fail
2
ACT FAIL SF1 SF2 INT EXT HLD LP
2
ACT FAIL SF1 SF2 INT EXT HLD LP
P1
P1
P2
P2
47
KNG-AM1
Working EAST
Protection WEST
2
ACT FAIL SF1 SF2 INT EXT HLD LP
2
ACT FAIL SF1 SF2 INT EXT HLD LP
P1
P1
P2
P2
48
KNG-AM1
Working
Protection
Working
Protection
Working
Protection
2
ACT FAIL SF1 SF2 INT EXT HLD LP
2
ACT FAIL SF1 SF2 INT EXT HLD LP
P1
P1
P2
P2
Working
Working
Working
49
KNG-AM1
Working
Working
Working
Working
Working
Working
Working
Working
Working Protection
2
ACT FAIL SF1 SF2 INT EXT HLD LP
2
ACT FAIL SF1 SF2 INT EXT HLD LP
P1
P1
P2
P2
Working
Working
Working
Working
Working
Working
Working
Working
Working
50
KNG-AM1
Configuration - Basic
Up-link : STM-1 2 circuits (P-to-P or Ring) Down-link : Front : PSU-A/D(2) + OTU2(2) + RMCU Rear : PSU-IO(2) + CLK-IO + ALM-IO + MSC-IO
2
ACT FAIL SF1 SF2 INT EXT HLD LP
2
ACT FAIL SF1 SF2 INT EXT HLD LP
P1
P1
P2
P2
51
KNG-AM1
Configuration case 1
Up-link : STM-1 2 circuits (P-to-P or Ring) Down-link : DS-1E 63 circuits or DS-1 72 circuits Front : D1U(10) Rear : D1U-IO(9)
CH 1~8
CH 9~16
2
ACT FAIL SF1 SF2 INT EXT HLD LP
2
ACT FAIL SF1 SF2 INT EXT HLD LP
P1
P1
P2
P2
Working
Working
Working
Working
Working
Working
Working
Working
Working
52
KNG-AM1
Configuration case 2
Up-link : STM-1 2 circuits (P-to-P or Ring) Down-link : DS-3 3 circuits Front : D3U(6) Rear : D3U-IO(3)
CH 1
Protection
CH 2
Protection
CH 3
Protection
2
ACT FAIL SF1 SF2 INT EXT HLD LP
2
ACT FAIL SF1 SF2 INT EXT HLD LP
P1
P1
P2
P2
Working
Working
Working
53
KNG-AM1
Configuration case 3
Up-link : STM-1 2 circuits (P-to-P or Ring) Down-link : 100BaseTx 12 ports Front : OEU + FBU Rear : EIU-IO + EIU-IO2
Port 1~8
2
ACT FAIL SF1 SF2 INT EXT HLD LP
2
ACT FAIL SF1 SF2 INT EXT HLD LP
P1
P1
P2
P2
Port 5~12
Port 1~4
9 9 10 10 11 11 12 12
6 7 8
54
KNG-AM1
Configuration case 4
Up-link : STM-1 2 circuits (P-to-P or Ring) Down-link : DS-3 1 circuit, DS-1E 21 circuits, 100BaseTx 4 ports, 100BaseFx 4 ports Front : D3U(2) + D1U(4) + OEU + FBU Rear : D3U-IO + D1U-IO(3) + EIU-IO + EOU-IO
CH 1
Protection
Protection
Port 1~8
2
ACT FAIL SF1 SF2 INT EXT HLD LP
2
ACT FAIL SF1 SF2 INT EXT HLD LP
P1
P1
P2
P2
Port 5~8
Port 1~4
OUT
IN
OUT
IN
OUT
IN
OUT
IN
55
56
KNG-AM16
Layout - Front
FANU
-1 -1 SF-2 RDI-2
-1 -1 SF-2 RDI-2
OUT 2 IN 2
OUT IN
STM16U/16U2
EOS16U
TSIU
STM4U STM1U
DS3U DS1U
MCU
Proprietary of Kisan Telecom 57
KNG-AM16
Layout - Rear
Power IN DS-1E 32 DS-3 12 External Clock IN/OUT 2 EOS FE 16
MCU-IO
DS3U-IO DS1U-IO
EOS16U-IO
Proprietary of Kisan Telecom 58
KNG-AM16
59
KNG-AM16
60
KNG-AM16
Units
Board MCU TSIU STM16U STM16U2 EOS16U STM4U STM1U DS3U DS1U MCU-IO Description Main controller, EMS/CIT interface 10G switching capacity, System Clock generator 1 x STM-16 Optical line interface 2 x STM 16 O ti l li i t f STM-16 Optical line interface Ethernet-over-Sonet, 48 EoS channel, Ethernet switching 1 x STM-4 Optical line interface p 4 x STM-1 Optical line interface 12 x DS3 Line Interface Unit 32 x DS1/1E Line Interface Unit DC -48V Power input terminal External Alarm interface (External PDP) Housekeeping (4 input port, 4 output port) EMS/CIT interface 16 x 100BaseTx interface, RJ45 connector External clock interface, 2 input/out clock 12 x DS3 Line interface, BNC connector 32 x DS1/1E Line interface, 64-pin Champ connector FAN U it Unit Slot MCU_A, MCU_B TSIU_A, TSIU_B STM16U_1A/1B, STM16U_2A/2B STM16U_1A/1B, STM16U_2A/2B STM16U 1A/1B STM16U 2A/2B EOS16U_1, EOS16U_2 LIU_1A/1B/2A/2B/3A/3B/4A/4B LIU_1A/1B/2A/2B/3A/3B/4A/4B _ LIU_1A/1B/2A/2B/3A/3B/4A/4B LIU_1A/1B/2A/2B/3A/3B/4A/4B MCU_A(Rear) + MCU_B(Rear) 1 2 4 2 2 8 8 8 8 1 Max
PSU_A, PSU_B LIU_1A+1B, LIU_2A+2B LIU_3A+3B, LIU_4A+4B LIU_1A+1B, LIU_2A+2B LIU_3A+3B, LIU_4A+4B FTU_1/2/3 FTU 1/2/3
1 4 4 3
61
KNG-AM16
MCU
System initialization Provisioning Alarm report DCC channel control System error monitoring
Panel ACT FAIL CR MJ MN ACO HIS LT ACO RST EMS ACT (EMS) LINK (EMS) CIT LED LED LED LED LED LED LED Push button 3-Pole Switch Push button RJ-45 Connector LED LED RS-232 (9-pin) Conn. Type Color GREEN RED RED RED YELLOW YELLOW YELLOW GREEN GREEN System Fail CRITICAL alarm MAJOR alarm MINOR alarm ALARM-CUT-OFF ALARM CUT OFF status Alarm history LED ON/OFF test ALARM-CUT-OFF operation System Initialization EMS terminal interface Data activity via EMS terminal Link status of EMS terminal CIT terminal interface
Proprietary of Kisan Telecom 62
KNG-AM16
TSIU
Time Slot Interchange System Reference clock generation 1+1 Equipment Protection External Reference clock interface
Function Normal & Active status l Board Fail E External Clock mode m Internal Clock mode Hold-over mode
63
KNG-AM16
STM16U
STM-16 optical line interface P-to-P, Ring, Multi-Ring SNCP, MS-SPRing 1+1 Equipment Protection 1 port STM-16 interface
Function Normal & Active status Board Fail Signal Fail on STM 16 line STM-16 Remote Defect Indicator (RDI) on STM-16 line
64
KNG-AM16
STM16U2
2
-1 1 -1 SF-2 RDI-2
STM-16 optical line interface P-to-P, Ring, Multi-Ring SNCP, MS-SPRing 1+1 Equipment Protection 2 ports STM-16 interfaces
Panel ACT
OUT
Function Normal & Active status Board Fail Signal Fail on STM 16 line 1 STM-16 Remote Defect Indicator (RDI) on STM-16 line 1 Signal Fail on STM-16 line 2 Remote Defect Indicator (RDI) on STM-16 line 2
IN
65
KNG-AM16
EOS16U
EoS(Ethernet over SONET/SDH) service with 2.5Gbps channel capacity ( ) p p y 48 VCGs (Virtual Concatenation Groups) 8 x 10/100BaseTx or 6 x 100BaseFx Ethernet interface 2 x 1000BaseSx/Lx Ethernet interface
Panel ACT FAIL GBE 1 GBE 2 FE 1 FE 2 FE 3 FE 4 FE 5 FE 6 FE 7 FE 8 Type LED LED LED LED LED LED LED LED LED LED LED LED Color GREEN RED GREEN GREEN GREEN GREEN GREEN GREEN GREEN GREEN GREEN GREEN Normal operation Board Fail Link status & Activity of Gigabit Ethernet port 1 Link status & Activity of Gigabit Ethernet port 2 Link status & Activity of Fast Ethernet port 1 Link status & Activity of Fast Ethernet port 2 Link status & Activity of Fast Ethernet port 3 Link status & Activity of Fast Ethernet port 4 Link status & Activity of Fast Ethernet port 5 Link status & Activity of Fast Ethernet port 6 Link status & Activity of Fast Ethernet port 7 Link status & Activity of Fast Ethernet port 8 Function
66
KNG-AM16
STM4U
STM-4 optical line interface P-to-P, Ring, Multi-Ring SNCP 1+1 Equipment Protection 1 port STM-4 interface
Function Normal & Active status Signal Fail on STM-4 line Remote Defect Indicator (RDI) on STM-4 line
67
KNG-AM16
STM1U
STM-1 optical line interface P-to-P, Ring, Multi-Ring SNCP 1+1 Equipment Protection 4 ports STM-1 interfaces
Panel ACT1 ACT2 ACT3 ACT4 FAIL SF1 F RDI1 SF2 RDI2 SF3 RDI3 SF4 RDI4 Type LED LED LED LED LED LED E LED LED LED LED LED LED LED Color GREEN GREEN GREEN GREEN RED RED E YELLOW RED YELLOW RED YELLOW RED YELLOW Function Normal & Active status of STM-1 line 1 Normal & Active status of STM-1 line 2 Normal & Active status of STM-1 line 3 Normal & Active status of STM-1 line 4 Board Fail Signal F l on STM-1 l l Fail line 1 Remote Defect Indicator (RDI) on STM-1 line 1 Signal Fail on STM-1 line 2 Remote Defect Indicator (RDI) on STM-1 line 2 Signal Fail on STM-1 line 3 Remote Defect Indicator (RDI) on STM-1 line 3 Signal Fail on STM-1 line 4 Remote D f R Defect I di Indicator (RDI) on STM-1 line 4 STM 1 li
68
KNG-AM16
DS3U
DS-3 line interface 1:1 Equipment Protection 12 ports DS3 interfaces
Panel ACT FAIL LF1 LF2 LF3 LF4 LF5 LF6 LF7 LF8 LF9 LF10 LF11 LF12
Type LED LED LED LED LED LED LED LED LED LED LED LED LED LED
Color GREEN RED YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW Board Fail
Function Normal & Active status Line Fail on DS-3 line 1 DS 3 Line Fail on DS-3 line 2 Line Fail on DS-3 line 3 Line Fail on DS-3 line 4 Line Fail on DS-3 line 5 Line Fail on DS-3 line 6 Line Fail on DS-3 line 7 Line Fail on DS-3 line 8 DS 3 Line Fail on DS-3 line 9 Line Fail on DS-3 line 10 Line Fail on DS-3 line 11 Line Fail on DS-3 line 12
69
KNG-AM16
DS1U
DS-1/1E line interface 1:1 Equipment Protection 32 ports DS1/1E interfaces
Panel ACT FAIL LF1 LF2 LF3 LF4 LF5 LF6 LF7 LF8
Type LED LED LED LED LED LED LED LED LED LED
Color GREEN RED YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW YELLOW Board Fail
Function Normal & Active status Line Fail on DS-1 line 1~4 Line Fail on DS-1 line 5~8 Line Fail on DS-1 line 9~12 Line Fail on DS-1 line 13~16 Line Fail on DS-1 line 17~20 Line Fail on DS 1 line 21~24 DS-1 Line Fail on DS-1 line 25~28 Line Fail on DS-1 line 29~32
70
KNG-AM16
MCU-IO
A/B two sets of -48V DC system p y power interface System alarm (audible, critical, major, minor) interface (PDP connection) RS-232 connection with CIT terminal LAN connection with f EMS t ti ith for terminal i l Housekeeping, 4 Input, 4 output port
71
KNG-AM16
EOS16U-IO
External Reference Clock interface 16 ports 100BaseTx interface RJ45 connector
72
KNG-AM16
DS3-IO
12 x DS-3 line interface via BNC connector
PIN 1 2 3 4 5 6 7 8 9 10 11 12
Name 01_DS3_IN 01_DS3_OUT 02_DS3_IN 02 D 3 N 02_DS3_OUT 03_DS3_IN 03_DS3_OUT 04_DS3_IN 04_DS3_OUT 05_DS3_IN 05_DS3_OUT 05 DS3 OUT 06_DS3_IN 06_DS3_OUT
Function DS3 input 1 DS3 Output 1 DS3 i D 3 input 2 DS3 Output 2 DS3 input 3 DS3 Output 3 DS3 input 4 DS3 Output 4 DS3 input 5 DS3 Output 5 O t t DS3 input 6 DS3 Output 6
PIN 13 14 15 16 17 18 19 20 21 22 23 24
Name 07_DS3_IN 07_DS3_OUT 08_DS3_IN 08 D 3 N 08_DS3_OUT 09_DS3_IN 09_DS3_OUT 10_DS3_IN 10_DS3_OUT 11_DS3_IN 11_DS3_OUT 11 DS3 OUT 12_DS3_IN 12_DS3_OUT
Function DS3 input 7 DS3 Output 7 DS3 i D 3 input 8 DS3 Output 8 DS3 input 9 DS3 Output 9 DS3 input 10 DS3 Output 10 DS3 input 11 DS3 O t t 11 Output DS3 input 12 DS3 Output 12
73
KNG-AM16
DS1-IO
32 x DS-1/1E line interface via 64-pin Champ connector p p
PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Name RX_TIP_1 RX_RING_1 RX R NG 1 RX_TIP_2 RX_RING_2 RX_TIP_3 RX_RING_3 RX_TIP_4 RX_RING_4 RX_TIP_5 RX TIP 5 RX_RING_5 RX_TIP_6 RX_RING_6 RX_TIP_7 RX_RING_7 RX_TIP_8 RX_RING_8 RX RING 8 Function DS1/1E input TIP signal 1 DS1/1E D 1/1E input RING signal 1 R NG l DS1/1E input TIP signal 2 DS1/1E input RING signal 2 p g DS1/1E input TIP signal 3 DS1/1E input RING signal 3 DS1/1E input TIP signal 4 DS1/1E input RING signal 4 DS1/1E i input TIP signal 5 t i l DS1/1E input RING signal 5 DS1/1E input TIP signal 6 DS1/1E input RING signal 6 DS1/1E input TIP signal 7 DS1/1E input RING signal 7 DS1/1E input TIP signal 8 DS1/1E i input RING signal 8 t i l
74
KNG-AM16
Basic Configuration
Up-link : Down-link : Front : MCU + TSIU(2) + FTU(3) Rear : MCU-IO + EOS16U-IO
FTU
TSIU
MCU
MCU-IO MCU IO
EOS16U-IO EOS16U IO
75
KNG-AM16
Configuration case 1
Up-link : STM-16 1 circuits (P-to-P, Ring) p ( g) Down-link : DS-1/1E 128 circuits (P-to-P) Front : STM16U(2) + DS1U(8) Rear : DS1-IO(4)
STM16U
DS1U
DS1-IO DS1 IO
76
KNG-AM16
Configuration case 2
Up-link : STM-16 1 circuits (P-to-P, Ring) p ( g) Down-link : DS-1/1E 128 circuits (P-to-P non-protection) Front : STM16U(2) + DS1U(4) Rear : DS1-IO(4)
STM16U
DS1U
DS1-IO DS1 IO
77
KNG-AM16
Configuration case 3
Up-link : STM-16 1 circuits (P-to-P, Ring) p ( g) Down-link : DS-3 48 circuits (P-to-P) Front : STM16U(2) + DS3U(8) Rear : DS3-IO(4)
STM16U
DS3U
DS3-IO DS3 IO
78
KNG-AM16
Configuration case 4
Up-link : STM-16 1 circuits (P-to-P, Ring) p ( , g) Down-link : STM-1 16 circuits (P-to-P) Front : STM16U(2) + STM1U(8) Rear :
STM16U
STM1U
BLK
79
KNG-AM16
Configuration case 5
Up-link : STM-16 1 circuits (P-to-P, Ring) p ( , g) Down-link : STM-1 16 circuits (P-to-P non-protection) Front : STM16U(2) + STM1U(4) Rear :
STM16U
STM1U
BLK
80
KNG-AM16
Configuration case 6
Up-link : STM-16 1 circuits (P-to-P, Ring) p ( , g) Down-link : STM-4 4 circuits (P-to-P, Ring) Front : STM16U(2) + STM4U(8) Rear :
STM16U
STM4U
BLK
81
KNG-AM16
Configuration case 7
Up-link : STM-16 1 circuits (P-to-P,Ring) p ( , g) Down-link : 1000BaseSx/Lx 4 ports, 100BaseTx 16 or 100BaseFx 12 ports Front : STM16U(2) + EOS16U(2) Rear :
STM16U
EOS16U
BLK
82
KNG-AM16
Configuration case 8
Up-link : STM-16 1 circuits (P-to-P, Ring) p ( , g) Down-link : STM-4 1 circuits, STM-1 4 circuits, DS-3 12 circuits, DS-1/1E 32, 1000BaseSx/Lx 2 ports, 100BaseTx 8 or 100BaseFx 6 ports Front : STM16U(2)+EOS16U(1)+STM4U(2)+STM1U(2)+DS3U(2)+DS1U(2) Rear : DS1U(1)+DS3U(1)
STM16U
EOS16U
STM4U
DS3U DS1U
STM1U
KNG-AM16
Configuration case 9
Up-link : STM-16 3 circuits (P-to-P, Ring) p ( , g) Down-link : STM-1 8 circuits (P-to-P, Ring), 1000BaseSx/Lx 2 ports, 100BaseTx 8 or 100BaseFx 6 ports Front : STM16U2(2) + STM16U(2) + EOS16U(1) + STM1U(4) Rear :
-1 -1 SF-2 RDI-2
-1 -1 SF-2 RDI-2
9 OUT 2 IN 2 OUT IN
STM16U2
EOS16U
STM1U
BLK
STM16U
Toward a Leading Wireless & Wire Internet Access Solution Provider Proprietary of Kisan Telecom 84
Thank You. Th k Y
85