User Manual

Operation/Maintenance Terminal OMT Software

User Manual
(Operation/Maintenance Terminal OMT Software)
Manual Version 1.1

No part of this documentation may be excerpted, reproduced, translated, annotated or duplicated. In any form or by any means without the prior written permission of Netop Technology Co., Ltd

Copyright 2009 Netop Technology Co., Ltd. All rights reserved. Netop Technology Co., Ltd
B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707 Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

User Manual
Operation/Maintenance Terminal OMT Software

Contents
Hardware and Software Requirements ..................................................3 Chapter 1 .................................................................................................4 OMT Introduction ....................................................................................4
General Introduction ..................................................................... 4
Connecting Methods.................................................................................... 4 Functions .................................................................................................. 4

Main Menu of OMT Software ........................................................... 5


Menu BarConfiguration ............................................................................. 5 Menu BarTools ........................................................................................ 5 Menu BarHelp ......................................................................................... 5

OMT Interface .............................................................................. 6

Chapter 2 .................................................................................................7 OMT Install & Remove.............................................................................7


OMT Install................................................................................................ 7 OMT Remove ............................................................................................. 8

Chapter 3 .................................................................................................9 Configuration management (System Operation CM) .............................9


Set Communication/Local check ................................................................... 9 Set Communication/Modem check .............................................................. 10 Com Port Configuration ............................................................................. 10 Establishing Remote Connection ................................................................. 10

Chapter 4 ...............................................................................................12 Device Operation ...................................................................................12


Device Create .............................................................................12
Get MOID From Device.............................................................................. 12 User Configuration.................................................................................... 13

Configuring the Device .................................................................14


The scope of monitoring items: .................................................................. 14 Monitoring parameters interface description ................................................. 15
Netop Technology Co., Ltd
B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707 Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

-1-

User Manual
Operation/Maintenance Terminal OMT Software

Chapter 5 ...............................................................................................19 Fault Management (FM) ........................................................................19


Alarm Monitor Window .............................................................................. 19

Chapter 6 ...............................................................................................21 Upgrade..................................................................................................21


Upgrade Firmware By Local Mode ............................................................... 21 Upgrade Memmap by Local Mode................................................................ 22

Chapter 7 ...............................................................................................24 Others ....................................................................................................24


Alarm Level Configuration.......................................................................... 24 Cmcc Packet Analyzer ............................................................................... 25 Version information .................................................................................. 26

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

-2-

User Manual
Operation/Maintenance Terminal OMT Software

Hardware and Software Requirements

Supported Operating Systems: Windows XP ; Windows Server 2003; 2008; Windows Vista

Windows Server

Processor: 1GHz Pentium processor or equivalent (Minimum); 2GHz Pentium processor or equivalent (Recommended)

RAM: 256 MB (Minimum); 1GB (Recommended) Hard Disk: Up to 500 MB of available space may be required ; 1GB (Recommended) DVD Drive: required Display: 1024 x 768 high color, 16-bit (Minimum); 1280 x 1024 high color, 32-bit (Recommended)

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

User Manual
Operation/Maintenance Terminal OMT Software

Chapter

OMT Introduction
General Introduction
Connecting Methods
1. 2. Local Communication via RS232-cable. Remote Communication via Modem (Short Message).
Laptop with OMT software MU Site-B MU Site-A MU Site-C

Modem and cable

Network (SMS)

External Antenna

Functions
1. Control Functions Parameters of devices can be configured via local or remote communication. 2. 3. Search FunctionsCurrent parameter settings and alarm setting can be displayed. Alarm FunctionsActive alarms can send back to control center (OMT)

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

User Manual
Operation/Maintenance Terminal OMT Software

Main Menu of OMT Software


Menu BarConfiguration

1. 2.

MOID List Config: To define the parameters of the monitoring equipment. Alarm Level Config: To define the level of alarm items.

Menu BarTools

1. 2. 3.

Upgrade Firmware: To upgrade firmware by local communication. Upgrade Memmap: To upgrade memmap by local communication. Packet Analyzer: To analyze the data sent and received.

Menu BarHelp

1.

About: To display version of OMT and something about corporation.

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

User Manual
Operation/Maintenance Terminal OMT Software

OMT Interface
Menu Bar

Device Info.

Monitoring parameter list of the main interface

Alarm Monitor

Data Send & Receive


Communication Mode

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

User Manual
Operation/Maintenance Terminal OMT Software

Chapter

OMT Install & Remove


OMT Install
1. Double click the Setup.exe file in OMT installation folder 2. OMT installation interface ->Select path ->Click Next 3. Continuously click Next 4. Click Close and OMT installation finished

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

User Manual
Operation/Maintenance Terminal OMT Software

OMT Remove
1. Select program-Netop -> Uninstall OMT 2. OMT remove interface -> Select Yes

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

User Manual
Operation/Maintenance Terminal OMT Software

Chapter

Configuration management (System Operation CM)


Set Communication/Local check
1. Communication PortSelect the correct port number 2. Communication SpeedDefault: 9600 3. Communication ModeSelect RS232 4. Communication Timeout30 Sec.

1. R Switch: To refresh the serial port 2. Start: To establish connection between the computer and devices. 3. Stop: To terminate connection between computer and devices.

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

User Manual
Operation/Maintenance Terminal OMT Software

Set Communication/Modem check


1. Communication PortSelect the correct port number 2. Communication SpeedDefault: 9600 3. Communication ModeSelect SMS 4. Communication Timeout60 Sec.

Com Port Configuration


Note: Communication Port represents to the serial port used by the computer. Usually, serial port of the computers default setting is COM 1

For the latest laptop, which is not equipped with serial port, we have to create the serial port by USB-Serial conversion cable. In this condition, the COM port will not be COM1, but COM5 or COM6 etc.

Establishing Remote Connection


1. Connect a wireless modem to the computer of control center. 2. Login to the main screen of the OMT. Choose SMS

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

10

User Manual
Operation/Maintenance Terminal OMT Software

3. Create a new device Enter the SIM card number inside the devices modem in Device Phone column and then Set the site ID. 4. Set Remote Communication Setup Enter the SIM card number of the modem that will be connected with the laptop in Control Center Phone No.1~ 5 (You can set Phone2~5 or not). Choose Short Message as Remote Communication Mode, and then Set. User can choose suitable service that the operator has provided.

5. Click Get and then Search to confirm whether Remote Communication Parameters has been set successfully. 6. Connect the BTS port with donor antenna cable, before remote communication; it will take 1 minute for the initialization of the modem inside the device. 7. If Short Message is set during Remote Communication Setup setting, click Start. After 10 seconds, choose the site ID and then click Get. The devices parameters will be read and displayed on the screen.

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

11

User Manual
Operation/Maintenance Terminal OMT Software

Chapter

Device Operation
Device Create
Get MOID From Device
1. Equipment Number Select the equipment type(Single:FF Master:00 Slave:01~FE) 2. ProtocolSelect the protocol 3. Device PhoneConfigure the device phone number in remote mode 4. Open the com. port -> Click Get MOID From Device -> Build MOID list automatic

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

12

User Manual
Operation/Maintenance Terminal OMT Software

User Configuration
1. Build MOID list by user Configuration 2. Equipment Number Select the equipment type(Single:FF Master:00 Slave:01~FE) 3. ProtocolSelect the protocol 4. Device PhoneConfigure the device phone number in remote mode 5. Open Menu Bar->MOID List Config ->The user to configure the equipment needed for monitoring parameters 6. Open the com. port ->Choose Device Type -> Click User Configuration

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

13

User Manual
Operation/Maintenance Terminal OMT Software

Configuring the Device


The scope of monitoring items:
Scope
0x00000x00FF 0x01000x01FF

Items Device Information Monitoring Parameter Alarm Enable/Disable Alarm Status RF Parameters Operation Status

Description
Equipment general information Configure the number and Communication mode Equipment wont send the alarm when it is disable; and

0x02000x02FF

the alarm status will be normal when OMT enquiry it (Nonalarm status) Equipment will send out the related alarm when meet the alarm condition Details monitoring parameters of modules To provide the active sampling data of operating status to

0x03000x03FF 0x04000x04FF

0x05000x05FF

the OMC, and manage all the active sampling data of device modules

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

14

User Manual
Operation/Maintenance Terminal OMT Software

Scope
0x06000x09FF 0x0A000x0FFF

Items Engineering Parameter Custom Manufacturers

Description

Monitoring parameters interface description

1. Get: Search all the parameters checked 2. Set: Set all the parameters checked 3. Select All: Pick up all items in the interface 4. Clear All: Clear all items in the interface 5. MultiSelect: Pick up some items 6. MultiDeSelect: Clear some items 7. Check: Pick or Clear 8. SetValue: Set parameters according to type of equipment Grey one is not available
9.

GetValue: Display information of equipment. In Alarm Status will display Alarm or Normal

10. Unit: The unit of parameters

11. Status: Display feedback or not with Success or Failure, and no operation with None

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

15

User Manual
Operation/Maintenance Terminal OMT Software

Device Information

Monitoring Parameter (available to get and set)

Alarm Enable/Disableavailable to get and set

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

16

User Manual
Operation/Maintenance Terminal OMT Software

Alarm Status (available to get but can not set)

RF Parameteravailable to get and set

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

17

User Manual
Operation/Maintenance Terminal OMT Software

Operation Statusavailable to get but can not set

Engineering Parameter

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

18

User Manual
Operation/Maintenance Terminal OMT Software

Chapter

Fault Management (FM)


Alarm Monitor Window
Send alarm automatically Equipment sends the status automatically to OMC, such as alarm, alarm removed, and channel configured. The confirm package OMC feedback to equipment do not need any parameters and equipment can confirm it by package series number. Set Remote Communication Setup Enter the SIM card number of the modem that will be connected with the laptop in Report Phone No.12 (You can set Phone2 or not) . Choose Short Message as Remote Communication Mode, and then Set. User can choose suitable service that the operator has provided.

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

19

User Manual
Operation/Maintenance Terminal OMT Software

The items will display red highlight if the module is power off or unlinked.

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

20

User Manual
Operation/Maintenance Terminal OMT Software

Chapter

Upgrade
Upgrade Firmware By Local Mode
1. 2. 3. 4. 5.

Confirm the local communication is okay Click Tools -> Upgrade Firmware -> UpgradeFirmware interface Click button Open File ->Select upgrade application program file(.hex) -> Click OK Click Start -> Start obtain Firmware Version Display Erasing flashplease wait...

6. Display Upgrade in progress..., start udgrade


7.

Upgrade finished, display Upgrade Succeed! -> Click OK, upgrade successful!

8. Search Device Parameters -> Check the version Configuration Module Address00-FF Timer(Sec)5,10,20,30,60,90,120,200,600 Packet Size(Byte)1024,2048,3072,4096,7168 Send CountCount of package DeviceTypeEquipment type Firmware VersionDisplays the current Firmware version

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

21

User Manual
Operation/Maintenance Terminal OMT Software

Upgrade Memmap by Local Mode


1. 2. 3. 4. 5.

Confirm the local communication is okay Click Tools -> Upgrade Memmap -> Upgrade Memmap interface Click button Open File -> Select upgrade application program file(.hex) -> Click OK Click Start -> Start obtain Memmap Version Display Erasing flash... Upgrade finished, display Upgrade Succeed! -> Click OK, upgrade successful!

6. Display Upgrade in progress..., start upgrade


7.

8. Search Device Parameters -> Check the version

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

22

User Manual
Operation/Maintenance Terminal OMT Software

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

23

User Manual
Operation/Maintenance Terminal OMT Software

Chapter

Others
Alarm Level Configuration
Users can configure the alarm level flexibly according to the conditions of definition Alarm level definitions Alarm Level Serious Major 3 2 Description Interrupt the service of BTS coverage area and interference the network such as shut down, power off, self oscillations Interrupt the coverage of equipment or lower the service quality such as main modules are damaged Reduce the coverage range of equipment or lower the General Normal 1. 2. 3. 1 0 service damaged Alarm removed green quality such as functional components are yellow Color red orange

Configuration ->Alarm Level Configuration Choose Alarm Level Save

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

24

User Manual
Operation/Maintenance Terminal OMT Software

Cmcc Packet Analyzer


Transmit data packet analysis 1. Copy SendData or ReceiveData to the CmccPacketAnalyzer 2. Click Analyzerand the data will display as the following figure 3. Click Exit to escape

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

25

User Manual
Operation/Maintenance Terminal OMT Software

Data Send & Receive interface 1. Hex DisplayDisplay hexadecimal when selected, or display decimal 2. Clear AllClear all data display in the interface

Version information
Help ->About...

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

26

User Manual
Operation/Maintenance Terminal OMT Software

Revision Record
NETOP Operation/Maintenance Terminal OMT Software User Manual Title Document NO. Revision Description Date Writer Approved V1.0 V1.1 Operation/Maintenance Terminal OMT Software User Manual Release Increasing function on multi-system shows 2008-10-15 2009-07-23 Stella_Qian Stella_Qian ShiXin ShiXin

Netop Technology Co., Ltd


B2, No.303 XinKe Rd, Qingpu Industrial Zone, Shanghai, China P.C: 201707

Tel: +86 21 6921 4567 Fax: +86 21 6921 3655 www.netop-technology.com

27

You might also like