Wall Thickness
Mean outside
diameter
Class C
Class D
Class E
min
max
min
max
min
max
min
max
In
Mm
mm
mm
mm
mm
mm
mm
mm
21.2
21.5
1.7
2.1
26.6
26.9
1.9
2.5
33.4
33.7
2.2
2.7
42.1
42.4
2.2
2.7
2.7
3.2
48.1
48.4
2.5
3.0
3.1
3.7
60.2
60.5
2.5
3.0
3.1
3.7
3.9
4.5
88.7
89.1
3.5
4.1
4.6
5.3
5.7
6.6
114.1
11.5
4.5
5.2
6.0
6.9
7.3
8.4
140.0
140.4
5.5
6.4
7.3
8.4
9.0
10.4
168.0
168.5
6.6
7.6
8.8
10.2
10.8
12.5
218.8
219.4
7.8
9.0
10.3
11.9
12.6
14.5
10
272.6
273.4
9.7
11.2
12.8
14.8
15.7
18.1
12
323.4
323.3
11.5
13.3
15.2
17.5
18.7
21.6
14
355.0
356.0
12.6
14.5
16.7
19.2
20.5
23.6
16
405.9
406.9
14.5
16.7
19.0
21.9
23.4
27.0
Stocks are available with plain ends, solvent Sockets & Rubber Ring
sockets in standard lengths of 6 meters.
0
Pressure ratings for working pressures at 20 C
C 9.0 bar 130.0 Ibf/in 300 ft head
D 12.0 bar 173.0 Ibf/in 400 ft head
E 15.0 bar 217.0 Ibfin 500 ft head
a
UPvc Pressure Pipe
In accordance to BS 3506 : 1986
Mean
outside
diameter
min
Wall Thickness
Class O
Class B
Class C
Individual
Value
min max
Class E
max
min
max
max
13.6 13.9
min max
Class D
max
min max
max
min max
1.7
1.3 1.7
1.9
1.5 1.9
21.2 21.5
2.1
1.7 2.1
26.6 26.9
2.5
1.9 2.5
33.4 33.7
2.7
2.2 2.7
1 42.1 42.4
2.7
2.2 2.7
3.2
2.7 3.2
1 48.1 48.4
2.2
1.8
2.2
3.0
2.5 3.0
3.7
3.1 3.7
60.2 60.5
2.2
1.8
2.2
3.0
2.5 3.0
3.7
3.1 3.7
4.5
3.9 4.5
2 75.0 75.3
2.2
1.8
2.2
3.5
3.0 3.5
4.5
3.9 4.5
5.5
4.8 5.5
2.2
1.8
2.2
3.4
2.9 3.4
4.1
3.5 4.1
5.3
4.6 5.3
6.5
5.7 6.6
4 114.1 114.5
2.8
2.3
2.8
4.0
3.4 4.0
5.2
4.5 5.2
6.8
6.0 6.9
8.3
7.3 8.4
5 140.0 140.4
3.1
2.6
3.1
4.4
3.8 4.4
6.3
5.5 6.4
8.3
7.3 8.4
10.1
9.0 10.4
6 168.0 168.5
3.7
3.1
3.7
5.2
4.5 5.2
7.5
6.6 7.6
9.9
17 193.5 194.0
3.7
3.1
3.7
6.0
5.2 6.0
8.7
7.7 8.9
8 218.8 219.4
3.7
3.1
3.7
6.1
5.3 6.1
8.8
7.8 9.0
19 244.1 244.8
3.7
3.1
3.7
6.7
5.9 6.8
9.8
10 272.6 273.4
3.7
3.1
3.7
7.5
6.6 7.6
10.9
12 323.4 324.3
3.7
3.1
3.7
8.8
7.8 9.0
14 355.0 356.6
4.2
3.6
4.2
9.6
8.5 9.8
88.7 89.1
16 405.9 406.9
4.8
4.1
4.8
10.9
9.7 11.2 16.2 14.5 16.7 21.1 19.0 21.9 26.0 23.4 27.0
18 456.7 457.7
5.3
4.6
5.3
20 507.5 508.5
5.9
5.1
5.9
22 558.3 559.3
6.4
5.6
6.5
24 609.1 610.1
7.0
6.1
7.1
*I bar = 105 N/m2 Pipes to these nominal sizes are not normally available from stock.
Note I : The pressures given at the top of the columns for Classes B,C,D and E are the maximum sustained working
pressures for which the pipes are suitable and are based on water at a temperature of 200C.
UPvc
Pressure Pipe
In accordance to DIN 8062 : 1988 (Based on ISI / I Metric Series)
Outside Diameter
mm
Wall thickness
Series 2
PN 4
Series 3
PN 6
Series 4
PN 10
Series5
PN 16
12
1.0
16
1.2
20
1.5
25
1.9
32
1.8
2.4
40
1.8
1.9
3.0
50
1.8
2.4
3.7
1.9
3.0
4.7
63
75
1.8
2.2
3.6
5.6
90
1.8
2.7
4.3
6.7
110
2.2
3.2
5.3
8.2
125
2.5
3.7
9.3
140
2.8
4.1
6.7
10.4
160
3.2
4.7
7.7
11.9
180
3.6
5.3
8.6
13.4
200
4.0
5.9
9.6
14.9
225
4.5
6.6
10.8
16.7
250
4.9
7.3
11.9
18.6
280
5.5
8.2
13.4
20.8
315
6.2
9.2
15.0
23.4
355
7.0
10.4
16.9
26.3
400
7.9
11.7
19.1
29.7
450
8.9
13.2
21.5
33.30
500
9.8
14.6
23.9
37.0
560
11.0
16.4
26.7
41.5
630
12.4
18.4
30.0
46.70
710
14.00
20.70
33.8
52.6
800
15.70
23.30
38.1
59.3
900
17.70
26.30
42.9
66.70
1000
19.70
29.20
47.6
74.10
1200
23.60
35.0
57.1
88.9
SN 2 SDR 51
SN 4 SDR 41
SN 8 SDR 34
min
max
min
max
min
max
min
max
110.0
110.3
3.2
3.8
3.2
3.8
125.0
125.3
3.2
3.8
3.7
4.3
160.0
160.4
3.2
3.8
4.0
4.6
4.7
5.4
200.0
200.5
3.9
4.5
4.9
5.6
5.9
6.7
250.0
250.5
4.9
5.6
6.2
7.1
7.3
8.3
315.0
315.6
6.2
7.1
7.7
8.7
9.2
10.4
+355.0
355.7
7.0
7.9
8.7
9.8
10.4
11.7
400.0
400.7
7.0
8.9
9.8
11.0
11.7
13.1
+450.0
450.8
8.8
9.9
11.0
12.3
13.2
14.8
500.0
500.9
9.8
11.0
12.3
13.8
14.6
16.3
630.0
631.1
12.3
13.8
15.4
17.2
18.4
20.5
+710.0
711.2
13.9
15.5
17.4
19.4
800.0
801.3
15.7
17.5
19.6
21.8
+900.0
901.5
17.6
19.6
22.0
24.4
1000.0
1001.6
19.6
21.8
24.5
27.2
1) 1 pipes to these nominal sizes are not normally available from stock.
2) SRD 51 is applicable for application area code U only.
UPVC Underground Drainage Pipe
In accordance toBS 4660:1973
Nominal
size
Extreme individual
outside diameter
Minimum wall
thickness other
than sockets
mm
max
min
max
min
mm
mm
mm
mm
110.0
110.0
110.4
108.0
112.4
3.2
160.0
160.0
160.6
157.1
163.5
4.1
mm
Mm
min
max
min
min
mm
mm
mm
mm
mm
200.0
200.0
200.6
196.3
204.3
4.9
250.0
250.0
250.7
245.4
255.4
6.1
315.0
315.0
315.9
309.2
321.8
7.7
(355.0)
355.0
356.0
348.4
362.6
8.7
400.0
400.0
401.0
392.5
408.5
9.8
(450.0)
450.0
451.0
441.5
459.5
11.0
500.0
500.0
501.0
490.5
510.5
12.2
(560.0)
560.0
561.0
549.3
571.7
13.7
630.0
630.0
631.0
617.9
643.1
15.4
UPVC PIPES
UPVC Soil and Waste Pipes In accordance to BS 5255 : 1989
Nominal Size
Min
Max
mm
mm
1- /32
36.15
36.45
2.2
1- / 40
42.75
43.05
2.3
2 / 50
55.75
56.05
2.4
mm
Nominal sizes
Schedules 40
Wall thickness
Minimum wall
thickness
min
mm
3.2
3.2
3.2
Schedules 80
Wall thickness
min
max
min
max
min
max
mm
mm
mm
mm
mm
mm
21.24
21.44
2.77
3.28
3.73
4.24
26.57
26.77
2.87
3.38
3.91
4.42
33.27
33.53
3.38
3.89
4.45
5.08
42.03
42.29
3.56
4.06
4.85
5.44
48.11
48.41
3.68
4.19
5.08
5.69
60.17
60.47
3.91
4.42
5.54
6.20
72.84
73.20
5.16
5.77
7.01
7.85
88.70
89.10
5.49
6.15
7.62
8.53
101.40
101.80
5.74
6.43
8.08
9.04
114.07
114.50
6.02
6.73
8.56
9.58
141.05
141.55
6.55
7.34
9.52
10.67
168.00
168.56
7.11
7.98
10.97
12.29
218.70
219.46
8.18
9.17
12.7
14.22
10
272.67
273.43
9.27
10.39
15.06
16.87
12
323.47
324.23 10.31
11.56
17.45
19.52
SDR 26
160 PSI
SDR 21
200 PSI
SDR 17
250 PSI
SDR13.5
315 PSI
0.062
0.840
1.050
0.060
0.062
0.078
1.315
0.060
0.063
0.077
0.097
1.660
0.064
0.079
0.098
0.123
1.900
0.073
0.090
0.112
0.141
2.375
0.091
0.113
0.140
0.176
2.875
0.110
0.137
0.169
0.213
3.500
0.108
0.135
0.167
0.206
0.259
4.500
0.110
0.138
0.173
0.214
0.265
0.333
6.625
0.162
0.204
0.255
0.316
0.390
0.491
8.625
0.210
0.265
0.332
0.410
0.508