Chilled water cassette fan coil unit

MCK
Speed
Air side Air flow
Nominal cooling capacity
General Sensible cooling capacity
Nominal Heating capacity
Water flow
Coil side Pressure drop
Maximum working pressure
Power input
Motor
Current input
Noise
Power supply
Controller
Width
Dimension Depth
Height
Inlet/outlet nozzle
Pipe size
Condensate pipe diameter
Weight
Loading qty 20' 40' 40H'
Model

Characteristics
Chilled water cassette unit for false ceiling
installation with direct air inlet and outlet
Low noise
Optimizer diffusing type
Self-supporting structure made of galvanized
sheet metal complete with device for the natural
discharge and condensate pump
-speed fan motor
Infrared remote controller

Available configurations
MCK

200
C
2-R-1
()
() () (4)
(1) Nominal Air Volume:CFM
(2) Quantity of Coils:
2: Two pipes
4: Four pipes
(3) Direction of Nozzle:
L Left hand side
R Right hand side

Applications

Functions and features

(4) Power Supply:


1 220/1/50
3 230/1/60
6 Other power supply

Size
H
350

.44


200C
M L
260 220
.8 .6
1.30 .5
.55 .9
0.178
8

m/h
KW
KW
KW
l/s
KPa
MPa
W
5
A
0.16
dB(A) 4 5 8

mm
mm
mm
DN
DN
kg
Pcs

H
500
.8
2.02
4.

4

650
650
85

300C
M
L
450 330
.5 .4
.8 .6
3.57 3.06
0.238

40
0.18
37 9

H
710
.5
.5
5.5

4

650
650
85

400C
M
L
620 540
.5 .8
2.27 2.02
4.46 .8
0.28

50
0.22
37

9

650
650
85

4
5
27
120 267 305 120 267 305 120 267 305

600C
800C
1000C
M
L
H
M
L
H
M
L
H
840 660 1250 950 720 1600 1250 900 2000
4.95 4.4 6.6 5.94 5.8 8.5 7.65 6.8 
.56 3.17 4.75 4.8 3.80 6. 5.5 4.90 7.92
7.0 6.03 9.9 8.4 7.23 12.75 10.82 9.30 6.5
0.326
0.344
0.399
9

4
1.60
105
5
55
0.45
0.51
0.68
44 8 30 46 4  48
4  49
220V/1P/50Hz
Remote or wall pad
950
950
950
950
950
950
310
310
5
20
20
8
48
50
64 44 54 64 44 54 64 44 54 64

1200C
M
L
1600 1320
9.9
8.8
7.13 6.4
14.05 12.05
0.454
37

600C
800C
M
L
H
M
L
840 660 1250 950 720
4. . 5.8 4.7 3.7
3.02 .8 4.8 .8 .66
3.08 .6 4.4 .66 .
0.326
0.344
9

1.60
105
5
0.45
0.51
44 8 30 46 4 
220V/1P/50Hz
Remote or wall pad
950
950
950
950
310
310
20
20
8
48
64 44 54 64 44 54

1200C
M
L
1600 1320
6.8
5.5
4.90 .96
5.73 4.9
0.454
37

H
1020
5.5
.96
8.5

210
0.92
45

4

950
950
5

5
44

54

4 pipes installation
MCK
Speed
Air side Air flow
Nominal cooling capacity
General Sensible cooling capacity
Nominal Heating capacity
Water flow
Coil side Pressure drop
Maximum working pressure
Power input
Motor
Current input
Noise
Power supply
Controller
Width
Dimension Depth
Height
Inlet/outlet nozzle
Pipe size
Condensate pipe diameter
Weight
Loading qty 20' 40' 40H'
Model

Size
H
350
.8
.
.5

200C
M L
260 220
1.647 .
.9 0.95
. 0.85
0.178
8

m/h
KW
KW
KW
l/s
KPa
MPa
W
5
A
0.16
dB(A) 4 5 8

mm
mm
mm
DN
DN
kg
Pcs

650
650
85

H
500
.5
1.80
.

4

300C
M
L
450 330
. 2.01
.66 .45
.56 .
0.238

40
0.18
37 9

650
650
85

H
710
.
2.30
.

4

400C
M
L
620 540
.8 .4
2.02 1.73
2.08 .86
0.28

50
0.22
37

9

650
650
85

4
5
27
120 267 305 120 267 305 120 267 305

H
1020
5.
3.74
.6

1000C
H
M
L
H
1600 1250 900 2000
7.7 5. 5.00 8.5
5.54 4.66 3.60 6.
6.00 5.6 4.4 6.66
0.399
4

48

55
0.68
4



49

950
950
5

64

50
44

210
0.92
45

4

950
950
5

54

64

Note:
Cooling rated conditions: air inlet 27C(DB)/19.5C(WB). Water inlet 7C, water inlet/outlet temperature difference 5 C.
Heating rated conditions: air inlet 20C(DB), hot water inlet 60C, the hot water fiow is the same as the cooling water flow.
Noise measured at m in open field.

5
44

54

You might also like