SIMOREG
SIMOREG DC-MASTER
ONE DRIVE
ALL APPLICATIONS THROUGHOUT THE POWER RANGE THROUGHOUT THE WORLD
SIMOREG A&D LD 2005 Exider Dome System overview.ppt 16.08.2005
15 - 280 A
s
S I MO RE G
400 - 600 A
s
S I MO R E G
720 - 850 A
s
950 - 1200 A
s
1500 - 3000 A
s
S I MO G RE
S I MO RE G
S I MO R E G
Width: 265 mm Height:385mm (350 mm) Depth: 15A/30 A 239 mm 60-280 A Widht: 268 mm Widht: 268 mm 283 mm Height:625 mm Height:700 mm 460V/60-280A (585 mm) (660 mm) 313 mm Depth:318 mm Depth:362 mm
Dimensions
SIMOREG A&D LD 2005 Exider Dome System overview.ppt 16.08.2005
Configurable for 230 or 460VAC 3-ph. supplies 1180,1660 & 1680A units (capable 575VAC) PMs rated 575VAC
Base Drives include: - Power Module - Line Fuses - Control Transformer - Contactor All components are mounted & prewired on a Base panel.
Line supply voltage required The possible DC output voltage depends on the line supply voltage -and not on the rated drive unit voltage 1Q: Line supply voltage * 1.2 = possible DC output voltage 4Q: Line supply voltage * 1.05 = possible DC output voltage This data applies for a 5% line supply undervoltage (a 5% margin has been included). 4% voltage drop across the commutating reactor has been taken into account For a detailed calculation, refer to the Application Brochure: Engineering tips Minimum possible rated line supply voltage for drive units with a rated input voltage of up to 575 V is 85 V Option L04 (low voltage) for rated line supply voltages, armature circuit 15 to 85 V Rated line supply voltage range for the field supply: 400 V drive units: 85 V to 400 V +15% For drive units with higher rated voltages: 85 V to 460 V +15% Possible DC output voltage, field supply: Line supply voltage * 0.81 = possible DC output voltage with 5% line supply undervoltage and 4% voltage drop across the commutating reactor
Required drive converter current The specified rated drive converter current is the continuous current Overload is not possible for continuous operation with the rated current For operation with a base load current less than the rated current - overload is possible for a specific time Maximum overload current = 1.8 * rated current Overload is engineered/dimensioned according to: Chapter 5 of Catalog DA21.1 or using SIZER Overload is quickly selected according to load types DC I to DC IV or US rating Refer to Catalog DA21.1, Page 5/14 DC I: 100 % continuous current IDC I DC II: IDC II for 15 min and 150% IDC II for 60 s DC III: IDC III for 15 min and 150% IDC III for 120 s DC IV: IDC IV for 15 min and 200% IDC IV for 10s US rating: As for DC II however for an ambient temperature of 45 C The line current 3-ph. = DC current * 0.82
Interface to Customer
AC field
DC field
Tacho or encoder Line protection
Electronics box
Control terminals
Fast current control with pre-control Automatic restart within 2 failure - switches onto a Automatic optimization Menu-promted
Fast, simple
Standard software functions Features Function blocks can be freely assigned to cycle times Freely-connectable function blocks using BICO technology Software update without replacing a board (Flashmemory) Customer Benefits Highly dynamic performance drives Fast and flexible adaption to the control of the machine
No danger to electronics boards/ modules Simple handling through downloading Simple software updates
Control terminals in the basic drive Pulse encoder evaluation, 2 tracks + zero mark 4 binary, inputs, 2 selectable 2 binary selectable outputs (100 mA short-circuit proof) 2 analog inputs 14 bit via differential amplifier 0 to 10 V or 0 to 20 mA or 4 to 20 mA 2 analog selectable outputs 11 bits, 0 to 10 V 1 real-time output, analog 0 to 10 V for current actual value Reference voltage P10, N10 (10 mA) 1 RS232 / RS485 interface 1 RS485 interface 1 motor temperature evaluation via KTY 84 or PTC Connector to OP1 S on the operator panel
10
Customer Benefits The investment in the encoder system depends on the system accuracy. No additional options are required on the DC unit.
tacho
normal encoders
Measured
Freely
11
Control terminals on the terminal expansion 4 binary selectable inputs 4 binary selectable inputs, floating, can be used as motor interface 2 binary selectable outputs (100 mA, short-circiut proof) 2 analog inputs, referenced to ground 10 bit, 0 to 10 V 2 analog selectable outputs 11 bit, 0 to 10 V 1 motor temperature evaluation via KTY 84 or PTC 1 RS 485 interface Interface to connect SIMOREG drives in parallel
12
SIMOREG DC-MASTER 6RA70 Digital inputs and outputs on CUD1 and CDU2
Features
Customer Benefits
12 digital inputs of which Relieves of the control of 10 are select inputs which drive-related functions can be assigned to approx. 100 binector inputs. Inexpensive supplementary functions 4 digital select outputs without supplementary which can be activated by hardware over 720 binectors Polarity and delay time for all outputs can be parameterized
13
SIMOREG DC-MASTER 6RA70 Digital inputs and outputs on CUD1 and CDU2
Indicates every relevant factor 2 inputs referred to ground without the cost of ( 10 bit) instrumentation Can be freely connected to every relevant point of control 4 analog selectable outputs with high resolution
Can
be freely connected to every relevant control test point filtering and polarity can be parameterized
Normalization,
14
5 analog outputs, of which 4 are freely selectable 4 binary outputs, freely selectable with 100 mA drivers 1 binary output (relay) for main contactor control
15
16
1 x RS232 (or RS485) for OP1 S or DriveMonitor 2 x RS485 (2 or 4-wire) for USS Protocol, Peer-to-peer connection PROFIBUS-DP (option) SIMOLINK (option) 1 x internal SSC to connect several units in parallel
17
2-processor system (C165 and C167) 16 Mbyte address area 83 ns instruction execution time
18
4 possible parameter sets. Drive converters can be used on various machines The parameter sets are Recipes can be flexibly selected via selected Binary input functions
Control
19
Synchronizing voltage direct from the power section, therefore insensitive phase sequence
Control voltage transformer not required Converter transformer with any vector group can be used Random phase sequence The electronics power supply can be directly connected to a "UPS"
20
Dynamic characteristic quantities of the control system Current controller rise time approx. 6 - 9 ms Speed controller rise time approx. 25 ms
21
Resolution of setpoints and actual values Speed setpoint digital analog Speed actual value digital analog Current setpoint digital Current actual value digital 15 bit 14 bit 15 bit 14 bit 15 bit 10 bit for the drive rated current
22
Hardware options
Slots for option boards Encoder (Sensor Boards) - SBP Pulse Encoder
CUD1 (+CUD2)
Fieldbus (Communication Boards) - CBP2 PROFIBUS DP (12 Mbaud) Technological link - SLB SIMOLINK I/O-boards (Expansion Board) - EB1, EB2
23
Customer benefits
Extremely fast bus cycle times DriveES can be directly PROFIBUS-DP
Fiber-optic cables are Optical Link Plug can be transfer (EMC) Flash memory Software updates without boards All standard functions of DP are available e. g. Sync-function
Software supported in S7 using function blocks Certified to the EN 50170 (DVA_S5 / DVA_S7)
24
Basic Electronics Drive-related open-loop and closed-loop control BICO-technology Self-optimization Comprehensive diagnostics Technology - Software Freely-configurable software blocks communication PC and external control connection (USS protocol) PROFIBUS-DP Direct drive-to-drive coupling (SIMOLINK) Peer-to-peer connection
SIMOREG A&D LD 2005 Exider Dome System overview.ppt 16.08.2005
25
CUD1
T400
26
Host- and bus systems are relieved In many cases a PLC is not necessary Cost savings Interfaces are reduced Open- and closed-loop control incorporate in the drive i.e. locally Transparent plant/system overview due to distributed configuration Less cabling and lower susceptibility to interference
27
Free logic function blocks Motorized potentiometer Ramp-function generator Polygon curve characteristics Limit value monitor Technological controller
28
Customer benefits
Technological functions with can be implemented without hardware costs Software modules simply parameterization. No programming knowledge
Speed and velocity computer Processing of binary signals Logic functions (AND, NAND, OR, XOR, changeover switch, connector converter, timers) Mathematical functions (adder, subtractor, divider multiplier, absolute value Processing analog signals (limit value generator,
-1
P332 (0) K
3 2 1 0 K0123
-1
10
y1
x
P567.01 bis .10 (0) X-Werte
+200%
29
BICO Technology
Software structure Two powerful processors (80C165 and 80C167) handle all closed-loop and drive control functions for armature and field circuits The control functions are realized using program modules which can be connected per parameter All important points of the control are accessible via BICO (binectors and connectors)
30
SIMOREG DC-MASTER 6RA70 User-friendly operator panel OP1S A&D LD Large Drives
SIMOREG DC-MASTER
Features
4-line clear text display with 16 characters Numerical keyboard Removable Parameter saving (up to 8 Data sets) Parameter sets can be UPREAD (DOWNLOAD) Menu prompted
Customer benefit
Indicates physical values No measuring equipment required Can also be used as hand-held unit Data storage Simple commissioning Fast, direct parameter access Fast, routine commissioning Applicable for all SIMOREG DCMASTER and SIMOVERT MASTERDRIVES
Exider Dome System overview.ppt 16.08.2005
31
Drive Monitor
Features
Customer benefit
Menu prompted Rapid commissioning commissioning Parameter sets Simple operator can be loaded control and saved and monitoring Operator control User-friendly via control word service Monitoring via status word Fault messages can be read Trace buffer can be read-out
32
Features
10 channels for diagnostics and support in fault-finding Output
Customer benefit
Short commissioningtimes No instrumentation via the serial and interface tools required via DriveMonitor Fast Storage scope troubleshooting functions integrated in the unit
33
Operator control and parameterization unit standard in the unit door User-friendly operator panel OP1 S (option) operator prompting clear text display DriveMonitor, operator / monitoring via PC
menu-prompted commissioning all parameter sets can be upread / downloaded all parameters can be set-up and monitored operator control / control (e. g. setpoint values,control commands) user-friendly evaluation of alarms / faults
Electronic parameterization replaces jumpers and solderlinks with software e. g. no more shunt resistor matching Flash-EPROM Simplifies software and firmware updates
34
Features Rated supply voltage up to 950 V Rated DC currents up to 6x 3000 A connecting a max. of 6 units in parallel
Customer benefits Available as chassis or cabinet units Unified up to high powers (approx. 15 MW) Reduced parts inventory because of uniformity of components High redundancy for uninterrupted operation
35
Features
Suitable for 1Q applications Control is SIMOREG DC-
Customer Benefits
Reduced the supply
36
Features
Mostly used for retrofit application Isolation voltage for each SIMOREG sum of both transformer windings For 1Q and 4Q Applications
37
Can be set by Field supply for large DC and parameters (reliable synchronous machines firing of the thyristors for Controls of solenoid magnets highly inductive loads) Additional Alpha W pulses to reach current zero before switch Off
38
Why DC?
A&D LD Large Drives
SIMOREG DC-MASTER
The DC drive has, as before, its justification. This is because the technology is mature and its ease of use.
With our SIMOREG drive converters, we have technological leadership worldwide. In many application areas, the DC drive can fully utilize its special strengths : - Optimum operating characteristics, high level of efficiency, ease of commissioning, high efficiency. - Well-proven, simple drive system. - The complete system is reliable and user-friendly. The strengths: - Extremely high control dynamic performance - Wide speed control range - Compact dimensions Low torque ripple at low speed - (extremely smooth running characteristics).
Exider Dome System overview.ppt 16.08.2005
39
Why DC ?
A&D LD Large Drives
SIMOREG DC-MASTER
40
DC Advantages
A&D LD Large Drives
SIMOREG DC-MASTER
DC motor+drive combination cheaper 50hp 2500hp DC drives are perceived to be simpler and have less In higher hp range the DC package is physically Since only one energy conversion DC drive is more DC motor has larger speed range with maximum DC is superior at low speed operation Also no cable distance limitations DC market is shrinking but installed base is very large efficient power parts smaller
41
Paper machines Rolling mill drives in the steel industry Lift and cable railway Mixing drives for the rubber industry Main drives for printing machines Traversing and elevating in the crane and related indutries Winder drives for foil, paper and wire Marine Propulsion Drilling Extruding Retrofits are by the largest market for DC today and in the
future