Mandalay

PLMN/PSTN
Yangon
HLR
Yangon
MSCe (V)
CS & PS Domain
PDSN AAA
BSC
Network Structure
BTS3606 Specifications
70dBA (The noise varies with the ambient temperature)
Cabinet dimensions
(Height x Width x Depth)
1400 mm x 600 x 650
Power supply
-48 V DC (ranging from-40 V DC to -60 V DC)

Weight 250 kg
Power consumption
3400 W
Ambient temperature
-5 C to 50 C
Relative humidity 5% to 90%
Equipment room noise

Reliability
Availability
99.999%
MTBF 100000 h
MTTR 1 h
BTS3606 Cabinet
(1) CDDU Sub rack
(2) Switch Box
(3)Fan Box
(4) Ccombined Sub rack
(5) Cable Trough
(6)Power Supply Sub rack
(7)Tool Kit
Installing Cabinet on Cement Floor
Installation Flowchart
Positioning the Cabinet
Determine the installation position of expansion bolts according to the
positioning dimensions specified in the project design and construction
blueprint and the location of installation holes on the cabinet.
Use a tape to determine the marking points according to the distance from the
cabinet to the reference.
Connect the marking points and draw two lines with 520 mm (20.47in.) interval
and parallel to the reference.
441 mm
520 mm 650 mm
600 mm
Front side
Side of cabinet
Positioning the Holes for Expansion Bolts
A. Settling the Drill Bit B. Drilling Holes
Move the base away and use a chisel to punch a pit
1) Hold the drill stock firmly and keep the drill
bit vertical to the ground.
2) Drill holes while using a vacuum cleaner to
clean the dust inside the holes.
Installing Expansion bolt Assembly
A. M12 Expansion Bolt Assembly B. Putting the Expansion Bolt Assembly into the Hole
1) Slightly tighten the expansion bolt assembly.

2) Put the expansion bolt assembly vertically into the hole.

3) Use a hammer to strike the expansion bolt assembly into the hole completely.
Unscrewing the bolt and accessory
Installing the Frame
1. Install the lower frame
Key points:
The insulation plate is installed correctly.
The fixing hole of the lower frame aimed at the hole of
the expansion bolt.
Ensure the space between the two lower frames.




2. Level the lower frame.
Key points:
Use the horizontal ruler.
Ensure that two directions of the cabinet are level.
The leveling pad is inserted to the correct place.
BTS3606
Install Module RF sub rack
Installing the CTRM
proceed as follows:
Make sure the subrack is clean.
Wear an antistatic wrist strap and insert the grounding terminal of the wrist strap into the anti-static jack on the
side door of the cabinet.
Align the CTRM with the relevant slot.
Insert the CTRM gently along the guide rail until it is fully engaged, as shown Figure
Installing the CTRM
Installing the CDDU Inside the Cabinet
Installing the CDDU Inside the Cabinet
To install the CDDU inside the cabinet, proceed as follows:
Remove the cover of the cabinet and the front plate of the CDDU subrack. Make sure that the internal
CDDU subrack is clean.
Wear an antistatic wrist strap and insert the grounding terminal of the wrist strap into the anti-static jack on
the side door of the cabinet.
Remove four black protective covers from both sides of the CDDU.
Align the CDDU with the relevant slot.
Insert the CDDU gently along the guide rail until it is fully engaged, as shown in
Installing the CDDU inside the cabinet
SECTOR 1
TX 1
SECTOR 1
RX 1
SECTOR 2
RX 2
SECTOR 3
RX 3
SECTOR 2
TX 2
SECTOR 3
TX 3
Installing the CDDU Inside the Cabinet
Internal cable wiring BTS 3606
S(1/1/1) Configuration
The S(1/1/1) refers to the configuration of three sectors, each of which is configured
with one carrier.
Shows RF cable connections, indicated by blue lines.
S(2/2/2) Configuration
The S(2/2/2) refers to the configuration of three sectors, each of which is configured with
two carriers
Install Power Cable
-48V2
-48V1
GND
PGND
Bar Ground
BTS 3606
PS48300
The overview of power connection
Installing Power Cables
The installation procedures of power cables include:
Preparing power cables
tools required: tape, wire nipper, paper knife, hydraulic pliers,
insulating tapes, soldering iron, and solder wire.

Connecting power cables
Connecting - 48 V Power Cable (Blue) or +24 V Power Cable (Red) to the Cabinet)
-48V1 -48V2 -48V1
BGND
PGND
RECTIFIER -48V1
BTS3606 -48V1
RECTIFIER -48V2
BTS3606 -48V2
RECTIFIER BGND1
BTS3606 BGND1
RECTIFIER BGND2
BTS3606 BGND2
3) The Power label (-48V From BTS3606) 4) The Power label (BGND From BTS3606)
Format Label on BTS3606
BTS3606 -48V1
RECTIFIER -48V1
BTS3606 -48V2
RECTIFIER -48V2
BTS3606 BGND1
RECTIFIER BGND1
BTS3606 BGND2
RECTIFIER BGND2
1) The Power label (-48V From Rectifier) 2) The Power label (BGND From Rectifier)
Format Label on Emerson Rectifier
Format Label on Emerson Rectifier and BTS3606
GROUND BAR
BTS3606 PGND
BTS3606 PGND
GROUND BAR
5) The PGND label (PGND From BTS3606)
6) The PGND label (PGND From GROUND BAR)
Install indoor cable ladder and feeder
Over view of RF Antenna &Feeder
S
e
c
t
o
r

Antenna
Feeder
Jumper
Jumper
BTS cabinet
Antenna
Feeder
Jumper
Jumper
BTS cabinet
S
e
c
t
o
r
C
B
S
e
c
t
o
r

S
e
c
t
o
r
A
Indoor feeder cable
Outdoor feeder cable
Grounding of lightning protection
Install Cable Ladder Install and feeder
Label No. 1 TX1/RX1
Label No. 2 TX2/RX2
Label No. 3 TX3/RX3
Install Cable Ladder Install and feeder
Install outdoor RF Antenna &Feeder
Over view of RF Antenna &Feeder
S
e
c
t
o
r

Antenna
Feeder
Jumper
Jumper
BTS cabinet
Antenna
Feeder
Jumper
Jumper
BTS cabinet
S
e
c
t
o
r
C
B
S
e
c
t
o
r

S
e
c
t
o
r
A
Indoor feeder cable
Outdoor feeder cable
Hoisting the Antenna onto the tower
Jumper shield
Antennas should be in the 45-degree protected area of lightning rod.

The curve waterproof of Cable Jumper
Curve water proof
Cover water proof
Prepare 7/8" antenna and feeder connector
(See the installation manual for more details)

Prepare Feeder Connector
Feeder Clamp
Route Antenna and Feeder
Make a water curve for the antenna and
feeder outside the feeder window entry.
Installed antenna and feeder nameplates
Installed 3-in-1 feeder clip
Route Antenna and Feeder

Grounding of installed on the tower ,
When feeder along the tower equal or less than 60 M
Grounding
point
1
2
3 4
Grounding of installed on the tower ,
When feeder along the tower equal or less than 60 M
Lead the earthing cable of a lightning earthing clip from the top down. The appropriate angle formed by the
clip and the feeder is not greater than 15.
Connect the earthling cables of the lightning earthling clips outside to the outdoor earthling bar or well-
grounded outdoor cabling rack.
Peel the antirust paint off the grounded point of the cabling rack. Recoat the point with antirust paint after
installing the earthling cable. Coat all the exposed connectors that are difficult to be wrapped in insulation
tape with antirust paint to guarantee good contact.
Install Lightning earthling Clip
From top to down
From down to top
Lightning Earth Accessories
Wrap the feeder with three layers of waterproof-insulating tape squeeze the tape stuck to the feeder to make sure
no air remains between the tape layers then wrap the water proof-insulating tape with PVC tape again to prevent
wearing and aging of the water proof-insulating tape
Wind three layers of waterproof and insulation tape around the clip. Wind the first layer from the bottom up, the
second from the top down, and the third from the bottom up.
Install Lightning earthing Clip
Water proof protection on the window inlet
Shield silicone water prove at feeder inlet (inside & outside container)
Inside container
Outside container
Install GPS/GLONASS
Position requirements for installation
WHBB23B
The support of the GPS/GLONASS antenna is fixed firmly. In the area of its 90-degree
vertical angle there is no barrier (check when the GPS/GLONASS antenna exist).
Support antenna GPS 90


0.5

1) Surrounding building or other obstacles 2) GPS/GLONASS Antenna
Installing Antenna Stands on Tower
Installing UNONCORE GPS Antenna
UTONCORE GPS antenna.
Lightning arrester
Installing UNONCORE GPS Antenna
Installing UNONCORE GPS Antenna
BTS
Ant.
Label 1
Label 2
Label 3
Label 4
Feeder Label
Installing label feeder
DDPU DDPU DDPU
ANT_0B
ANT_0B
ANT_0B
ANT_0B
ANT_0A
ANT_0A
ANT_0A
ANT_0A
ANT_0B
ANT_0B
ANT_0A
ANT_0A
ANT_0B
ANT_0B
ANT_0A
ANT_0A
ANT A ANT B ANT C
ANT_0B
ANT_0A
ANT_1B
ANT_1A
ANT_2B
ANT_2A
ANT_3B
ANT_3A
Sector 2 Sector 4 Sector 1 Sector 5 Sector3
ANT_4B
ANT_4A
Jumper 1/4
Jumper 1/2
Feeder 1-5/8 or 7/8
SECTOR 0
TRX 1
SECTOR 0
TRX 2
SECTOR 1
TRX 1
SECTOR 1
TRX 2
SECTOR 2
TRX 1
SECTOR 2
TRX 2
The label on Jumper Feeder BTS3606
Label on indoor Jumper BTS3606
The letters on the feeder nameplates are described as follows:
ANT_0A: Transmitting
ANT_0B: Receiving
ANT_1A:Transmitting
ANT_1B: Receiving
ANT_2A: Transmitting
ANT_2B: Receiving
Install Antenna and Feeder System Feeder Nameplate
ANT _ 0B
ANT _ 0A
ANT _ 1B
ANT _ 1A
l
ANT _ 2B
ANT _ 2A
7) The label on outdoor feeder 7/8
GPS _ 0
8) The label on outdoor feeder GPS
SECTOR 0 SECTOR 1
SECTOR 2
E1 Cable wiring
E1 cable connect from BTS to DDF box
On the wall
DB 25
DDF box
External alarm E1 cable
Grounding point
E1 cable terminate with DDF box
From BTS To microwave rack Connect ground cable
Vertical Ladder for DDF
DDF bundle cable for optic metro 1000 and Metro 3000
2.5 cm.
Wrap heat shrink
1 cm.
Stick label
2.5 cm.
Bundle cable line
Please put the heat shrink ,bundle the cable and stick label according this
picture ,Which connector not use cover it with the plastic sack