DATA CENTRE AND NETWORK

INFRASTRUCTURE UPGRADE

Agenda

Agenda
1
2

Company Profile
Design Overview
Data Center Infrastructure
Structured Cabling

Warranty, Services and


support

Added Value

1- Company Profile
3

Business Regions

Midis Group operates in THREE major regions:


Eastern
Europe

Middle East
Africa

Business
Fields
Midis Group covers market needs in FOUR business fields:
Computer Systems,
Networking &
Communications

Electronic
Components
& Peripherals

Site &
Power
Solutions

Software &
Professional Services

The Group
Structure:
35 Countries
115 Companies
4,000 Employees
3.1 Billions $

Midis
Group

Levant
Group

Europe
Group

Africa
Group

East Gulf
Group
(Oman & Qatar)

UAE
Group

Saudi
Group

Asia
Group

2 Countries
8 Companies
450 Employees
300Millions $

Go To Market / By Brand
IT Supplier

Software Solutions System Integration


& Prof Services
& Telecom

Local Office

Site & Power

Value Added
Distribution

Retail

MDS Grouth

MDS Oman ISO Certificates

Financial Stability

Rev in B$

Total 500 US Corporations


Microsoft
Apple
Emerson Electric
Midis Group
Dell
Hewlett-Packard
Intl Business Machines
Ingram Micro

12,063.10
73.7
156.5
24.5
2.209
56.9
120.4
104.5
37.83

Equity in B$

Rev / Equity

6,131.80

1.97

66.363
118.21
10.295
0.622
10.68
22.436
18.86
3.61

1.11
1.32
2.38
3.55
5.33
5.37
5.54
10.47

Well below the globally recommended threshold of 5


Well ahead of similar global companies
Well below the average across the industry

10

ENT MDS REFERENCES IN DATA CENTRE IN OMAN

1.

Majlis Oman

14. Electricity Holding Company

2.

State Audit

15. Sohar University

3.

Government of Oman

16. Olympic Committee

4.

TRA

17. Central Bank Of Oman

5.

Nawras Data Centre (4 DCs)

18. ITA

6.

Omantel Exchange ( 4 DCs)

19.DRC Clinic -Salalah

7.

NRAA

20. Muriya

8.

Oman Electricity Transmission Co.

21. Salalah Methanol

9.

Government Of Oman Haya Water

22. OCTAL-Salalah

10. National Museum

23. Nawras Salalah

11.

24. OMEFCO Salalah

Ministry of Tourism

12. 12. ORPIC Sohar


13. Oman Gas

11

S Sample List of Prestigious Data Center Clients

12

MDS Team Qualification

S&P Products Range


Uninterrupted Power System

USA/Eu

Precision Cooling & Chillers


DC System
Generator

USA/Eu
USA/Eu
France

Sealed Lead Acid Batteries

UK

Leak Detection System

France

Access Raised Flooring

Germany

BMS System
Fire Prevention System

Germany
UK

14

Why MDS

15

We are specialized in
Designing and Implementing
turnkey solution as per
Clients requirement.

We have the highest level of


Partnership with Market
Leading Companies.

In house technical expertise.


MDS believe in the necessity
of getting Client engineers
updated in all Data Center
new technology and trends.
Therefore, we are offering to
host quarterly technical
update sessions to your
engineers in different
selected topics.

16

WHY MDS Oman?

We have locally the right


resources to implement &
support.

MDS Oman have built the


biggest DC references in the
Country.

Empowering Omanization.

MDS proposed a local training


course for IT team.

17

2- Design Overview

18

Data Center Existing Layout

Glass Window

Non fire rated


existing
Gypsum
Partition

Block Wall

19

Data Center Proposed Layout

20

S&P Scope of Work


Access Raised
Raised Flooring
Flooring
Access
Civil
Civil

Fire Rated
Rated Doors
Doors
Fire
Block with
with Painting
Painting
Block
False Ceiling
Ceiling
False

Cooling
Cooling
System
System

CRAC
CRAC

Split Units
Units
Split

MARA
Data Center

Electrical
Electrical

Cables
Cables

MCB
MCB

DB
DB

Sockets
Sockets

Power Distribution
Distribution
Power
UPS
UPS
Cable Tray
Tray
Cable
Leak Detection
Detection
Leak

Security
Security

Temp.
Temp.
Sensor
Sensor

EMS System
System
EMS
Humi.
Humi.
Sensor
Sensor

FF System
System
FF

Fire Detection,
Detection, and
and
Fire
Suppression
Suppression

21

A. Civil & Interior Works


22

Proposed Civil Layout

23

Civil Work
Size of Doors
MDS proposed to supply and install 3 Nos. single leaf 1hrs fire
rated wooden doors.

Fire Rated Gypsum Partitions


Supply and Install 1 hrs. Fire rated gypsum board to create NOC
room and electrical room

Block Wall
We will supply & Install block wall between DC &Employees
office
False Ceiling System
We will supply & Install fire rated false ceiling. It will cover the
NOC room and electrical room

24

Access Raised Flooring

MERO Company started its activities in 1928 in


Berlin, Germany in economic and flexible access
floor systems for office buildings and computer
areas. MERO products are of high quality
standard which is assured by permanent internal
and external quality control, which are certified
according to DIN EN ISO 9001

Ferrari Abu Dhabi

EUROVEA,
Bratislava

Al Gurg Tower in
Dubai

25

Access Raised Flooring


Panel :Chipboard panel high density 720 kg/m
Type 5 NB 30, of 30.0 mm thick with 0.5mm
Steel Sheet on bottom and 0.9mm HPL cover,
Print 577, factory bonded on top.

Pedestal :Steel, type M20 D23 zinc coated


and yellow chromatized, adjustable, including
gasket & glue.

Stringer:Heavy Duty Steel, M type (30x30x1


mm, point load +500 N), to increase the load
bearing and lateral stability.
FFH :400 mm

26

B. Cooling System
27

Close Control Unit Precision Cooling

28

Close Control Unit Precision Cooling


Our Approach
Day 1 Cooling Requirements (4
RACKS)
No
Data Description
.
1 Total IT Load (4 racks * 8 Kw)
Solar (20w per Sq. Meter = 20 * 33
2
sq. Meter )
Lighting (20w per Sq. Meter = 20 * 33
3
Sq. Mete
People (100w per person = 100 * 5
4
people)
5 TOTAL COOLING REQUIRED
6 At 85% efficiency
The Cooling
Capacity
per each (8
Future
Cooling
Expansion
7
40KW/2duty

RACKS)

No
Data Description
.
1 Total IT Load (8 racks * 8 Kw)
Solar (20w per Sq. Meter = 20 * 33
2
sq. Meter )
Lighting (20w per Sq. Meter = 20 * 33
3
Sq. Mete
People (100w per person = 100 * 5
4
people)
5 TOTAL COOLING REQUIRED
6 At 85% efficiency
The Cooling Capacity per each
7
75KW/3duty

Heat Output
32,000

660

660

500

33,820
39,788

W
W

20000

Heat Output
64,000

660

660

500

65,820
75,693

W
W

25000

29

Close Control Unit Precision Cooling

30

Main Features of Emerson Closed Control Unit

31

Cooling Solution for Electrical room-Split A/C


Our Approach
No
Data Description
.
1 UPS heat Load 60 KVA
Solar (20w per Sq. Meter = 20 * 14 sq.
2
Meter )
Lighting (20w per Sq. Meter = 20 * 14 Sq.
3
Mete )
4 People (100w per person = 100 * 5 people)
5 TOTAL COOLING REQUIRED
6 At 85% efficiency
7 In Ton

We proposed to use
Condition systems

Heat Output
3,600

280

280

500
4,660
5,359
1.5

W
W
W
Ton

2 sets of Comfort Air

The CAC indoor units will be 1 No. running and 1


No. Standby, they are connect together through AC
control panel to work in sequence each one 12 Hrs.
also to run both in case of more heat load.
32

C. Electrical Scope

33

Electrical Scope-Single Line Diagram

34

Electrical Scope-Uninterrupted Power Supply (UPS)


Option1 :Standalone UPS :
The UPS size calculated according to the client existing
requirements to have 4 racks each one 8Kw.
Total Power
Total IT Load (4 racks * 8KW)
Other load for security Systems
(CCTV, BMS, Leak
detection,..etc.)
Safety Factor 10%
Total load Power Consumption
Total KVA Required with 1 PF
40KVA

32.00

kW

4.00
40.00
40
40

kW
kW
KW
KVA

40KVA

35

Electrical Scope-Uninterrupted Power Supply (UPS)

Option2 : APM Modular UPS (Recommended)


Install 2 modular UPS each one 60 KVA. Each UPS consist of 5
modules each one 30KVA=30KW. We are going to install now
2 modules to achieve 60KVA and in future we can add more
modules
23 U

23 U

1U
2U
1U
2U

Module 30 KVA
Module 30 KVA

1U
2U
1U
2U

3U

3U

5U

5U

5U

5U

5U

5U

Rack01

Rack02

RAck03

Rack04

Rack01

Module 30 KVA
Module 30 KVA

Rack02

RAck03

Rack04

36

Grounding and bonding


Grounding and bonding will
include Supplemental bonding
grid (SBG), rack bonding
conductor (RBG),
telecommunication grounding
bus bar (TGB), and
telecommunication bonding
backbone as per standards
TIA-942 and TIA-607 B

Racks and Cable Tray Grounding

37

D. Security System

38

Environment Monitoring Systems


We proposed NTI Environment Monitoring System
for the main Equipment Room. The system is offered
with Temperature & Humidity sensors, AC voltage
sensors, GSM Modem and other components as
requested in the RFP BOQ.

39

Access Control System

No.
1

4
5

Description

SUPREMA BIO ENTRY PLUS STAND ALONE


BIOMETRIC ACCESS CONTROL READER
WITH BUILTIN PROXIMITY CARD READER &
TCP/IP CONNECTIVITY.
BIOSECURITY POWER SUPPLY WITH
ENCLOSURE & BATTERY BACKUP.
BIOSECURITY EXIT BUTTON WITH
METALLIC FINISH.
BIOSECURITY ELECTROMAGNETIC LOCK
WITH BRACKET FOR SINGLE LEAF DOOR.

Picture

Unit

Qty

No.

No.

No.

No

40

Monitoring System
Ite
m

Description
HIKVISION DS2CD2112I INDOOR VANDAL
PROOF 1.3 MEGAPIXEL POE ENABLED NETWORK
DOME CAMERA WITH IR & 4MM FIXED LENS.

Picture

Unit

QTY

No.

No.

Rack Mounted , HIKVISION DS7608NISE/P 8


CHANNEL NVR WITH 4TB HDDb
2

41

E. Fire Fighting System


42

Fire Detection System


MDS proposed Tyco Safety products (UK) which proposing a combination of a fire
alarm panel and a fire extinguishing panel. Covering all parts of the Data
Centre.

Room Void between Ceiling & Raised Floor


Below the Raised floor.
Above the false ceiling.

MDS proposed NOVEC 1230

43

3. Warranty, Maintenance and Support Services

44

Warranty

All hardware products shall


carry a warranty at site ( parts+
labor + software and firmware
update) for
a period of 12
months from the date of
commissioning .

45

MDS Support Services


Remedial Maintenance Service
Remote Technical Support
Engineer On-site Support
Defective Parts /Replacement
Quarterly Preventive Maintenance
Manufacturer Trained Personnel
All our support capabilities (Personnel and
Parts) are locally available in Oman through
our Muscat offices
24x7 helpdesk services
The result of our excellent services: MDS is
currently responsible for the support and
maintenance of more than 30 data centers in
Oman, and another 100+ S&P Sites.

46

4. Added Values For This Project

Added Value

Oman Adoption
Program
(Omanisation)

Shadow Team
Support for
Operation
Readiness

Knowledge
Transfer Sessions

48

Q&A

49

50