Ejercicio 1:

Saturated steam at 0.276 MPa flows inside a steel pipe having an


inside diameter of 2.09 cm and an outside diameter of 2.67 cm.
The convective coefficients on the inner and outer pipe surfaces
maybe taken as 5680 and 22.7 W/m2K respectively The
surrounding air is at 294K. Find the heat loss per meter of bare
pipe and for a pipe having a 3.8 cm thickness of 85% magnesia
insulation on its outer surface.
Saturated steam at 0.276 MPa flows inside a steel pipe having an
inside diameter of 2.09 cm and an outside diameter of 2.67 cm.
The convective coefficients on the inner and outer pipe surfaces
maybe taken as 5680 and 22.7 W/m2K respectively The
surrounding air is at 294K. Find the heat loss per meter of bare
pipe and for a pipe having a 3.8 cm thickness of 85% magnesia
insulation on its outer surface.

Datos:
Valor
P1

0.276

D1

2.09

D2

2.67

5680- 22.7

3.8

T1

267

T2

294

K1

42.9

K2

0.0675

Unidad
MPa

Conversiones:
Valor

cm
cm
W/mK
cm

0.038

D1

0.0209

D2

Unidad
m
m
m

R1

0.0267
0.01045

R2

0.01335

W/m*k

R3

0.05135

W/m*k

A1

0.06565735

A2

0.08388072

A3

3.29983995
8
403.7

m
K

Solucin sin aislante:

Clculos:

Solucin con
aislante:

Clculo
s:

Ejercicio 2:
Encuentre el calor de transferencia a travs de la pared de la
tubera por unidad de longitud y tambin el flujo de calor
basado en la superficie interna y externa.

Datos
Diametro: 1.88cm =0.0188 m
Espeso: 0.391 cm= 3.91X10^-3
TI: 344 k
TE:367 K
TUBO DE ACERO

Clculo
s:Qr=2lk(T)/Ln(Ro/R1)

=2()(2)(1)(367-344)/Ln(1.88+(2)
(0.0391)/1.88))=7,066.69/0.811
=17,863.52
A1=(D)^2/4=(0.0188)^2/4=2.759X10^-4 m^2
A2=(D)^2/4= (0.026662)^2/4=5.5655X10^-4m^2

D1=q/A1= 17,863.52/2.77X10^-4=64,352,174.07 kw/m


D2= q/A2=17,863.52/5.5655X10^-4=32,096882.582 kw/m

Ejercicio 3:

The walls of the houses in a new estate are to be constructed using a cavity wall
design. This comprises an inner layer of brick (k=0.5 W/m*k and 120 mm thick),
an air gap an outer layer of brink (k=0.3W/m*k an 120mm thick). At the design
condition the inside room temperature is 20C, the outside air temperature is
-10C: the heat transfer coefficient on the inside is 10 W/m2K, that on the outside
40W/m2k, and that in the air gap 6W/m2k. What is the heat flux through the wall?

T2

Data:
H int: 10 w/m2 k
H ext: 40 w/m2 k
T int: 20C + 273.15 =293.15 K
T ext: -10 C + 273.15 = 263 K
Q=?
k int: w/m k
k ext: 40 w/m k

T1

120 mm

conv

cond

RESISTANCE
conv

conv

120 mm

cond

conv

Conversions

120mm = 0.12 m
X = 0.12 m

Ejercicio 4:

The Figure below shows a cross section through an insulated


heating pipe which is made from steel (k = 45 W / m K) with an
inner radius of 150 mm and an outer radius of 155 mm. The pipe
is coated with 100 m thickness of insulation having a thermal
conductivity of k = 0.06 W / m K. Air at Ti = 60C flows through
the pipe and the convective heat transfer coefficient from the air
to the inside of the pipe has a value of hi = 35 W / m2 K. The
outside surface of the pipe is surrounded by air which is at 15C
and the convective heat transfer coefficient on this surface has a
value of ho = 10 W / m2 K. Calculate the heat loss through 50 m
of this pipe.

Resistance

Conv.
Conv.

Cond.

Cond.

Operations:
R 1 conv.
6.063x10

K/W
r h 2 L

(0.15m)(35w/Mk)(2)(50m)
Ln(m)
0.032

R 2 cond. Ln (r/r)
2KL
= 2.2635X10 K/W
R3 cond.

Ln (r/r)

2KL
= 0.028

(45w/mk) (50m)
Ln(m)
=
m

14,137.2
0.5306
=

K/W

R 4 conv.
1
= 1.248X10
rh 2L

RT = 0.0298
W/K

(0.06w/mk
1 ) (50m)

18.849

(0.255m)(10w/mk)(2)(50m)

Q =

= 333.15K 288.15K =

1510.067 Watt
R

0.0298W/K

Ejercicio 5:
Una cava de congelacin est construida de paredes de 1 ft2
de superficie formadas por un capa de 10 in de concreto,
una capa de 4 in de lana y otra de 5 in de ladrillo de
construccin. Si la temperatura de las caras interna y
externa de la pared son -30 F y 77 F respectivamente
calcular ,a) la velocidad de transferencia de calor y b)
temperatura de la interfase concreto-lana y lana-ladrillo
Datos:
A= 1ft2
Capa de concreto: 10 in
Capa de lana: 4 in
Capa de ladrillo: 5 in
T int= -30 F
T ext = 77 F

10
in

4 in

5 in

Clculos:
=1.04 h F/btu.

= 15.74 h
F/btu
= 1.8931 h F/btu.

RT= R1+R2+R3= 1.04 h F/btu + 15.74 h F/btu + 1.8931 h


F/btu= 18.647 h F/btu

= 5.738
Btu/h

Clculo de temperaturas de las


interfaces:
T=
T1-T2
TA= T1-Ta
TB= Ta-Tb
TC= Tb-T2
Despejando la
formula
Ta= QR = ( 5.738 Btu/h)(1.893 h F/ Btu) = 10.15 F
Tb= QR = ( 5.738 Btu/h)(15.71 h F/ Btu) = 90.14 F
Tc= QR = ( 5.738 Btu/h)(1.04 h F/ Btu) = 5.96 F
T= T1-T2
TA= T1-Ta = 77 F 10.15 F= 66.14 F
TB= Ta-Tb = 66.14 F 90.14 F = -24
F
TC= Tb-T2 = -24 F -5.96 F = -29.96 F

Ejercicio 6:
Calcular la prdida de calor a travs de250 ft de longitud de tuberas de
acero de 2 pulgadas catalogo de 40 recubierto con una capa de
aislamiento de magnesio (k= 1.66 BTU/h ft F) de 102 mm de espesor, si
la temperatura interna del tubo es de 120 C y la externa del aislamiento
20 C.
Tubera de acero 2 pulgadas (D exterior= 2.375 pulgadas, D interno=
2.067 pulgadas), K tubo= 26 BTU/ h ft F

Ejercicio 7:

Un tubo de paredes gruesas de acero inoxidable con (k=21.63 w/m K


) y dimensiones de 0.0254m (Di) y 0.0508m (De) se recubre con una
capa de 0.0254 m de aislamiento de asbesto (k=0.2423 w/m K). La
temperatura de la pared interna del tubo es 811 K y la de la
superficie exterior del aislamiento es de 310.8 K. Para una longitud
de 0.305 m (1 ft) de tubera.
Calcular la prdida de calor y la temperatura en la interface entre el
metal y el aislamiento.
kB

kA

T1

Resistenci
as:

r1

r2
r3

Cond

Cond

T2

Solucin:

DATOS
Tubo de acero inoxidable
Ka= 21.63 W/m K
Di=0.0254 m
De=0.0508 m
X=0.0254 m (aislamiento de asbesto)
Kb=0.2423 W/m K
Ti=811 K
Te=310.8 K
L=0.305 m (1ft) tuberia

Temperatura de las interfaces:

Ejercicio 8:
Una corriente de aire que esta a 206.8kPa y a un promedio de 477.6K,
se est calentando a medida que fluye por un tubo de 2.54cm de
dimetro interior, a una velocidad de 7.56 m/s. El medio de calentamiento
es vapor condensado a 488.7K que se condensa en el exterior del tubo.
Puesto que el coeficiente de transferencia de calor para vapor
condensado es de varios miles de w/m^2K y la resistencia de la pared
metlica es muy pequea, se supondr que la T superficial de la pared
metlica en contacto con el aire es 488.7K.
Calcular Q para una relacin L/D > 60 y el flujo especfico Q/A.

Datos del sistema:


Aire a 206.8kPa
Taire= 477.6K
T2

Di= 2.54 cm
V = 7.56 m/s

Aire

T1

Tpared= 488. 7K
L/D > 60
Q= ?
Q/A= ?

*Nota: Se desprecian los valores k y h para el vapor condensado


y la pared de la tubera.

Propiedades del aire a


477.6K

= 2.65 x 10^-5 Pa*s


NPr= 0.729
Donde:
= Viscosidad
dinmica
NPr= Nmero de Prandtl

k = 0.03959 W/m*k
= 1.135 kg/m^3
Donde:
k= coeficiente de transferencia de
calor por conduccin
= Densidad del fluido

Clculo del nmero de


Reynolds
NRe= V

NRe= 0.0254m (6.71 m/s) (1.135 kg/m^3) =


7,299.7204
2.65 Pa*s

Clculo del nmero de Nusselt:


Nu= hD / K = (0.023Re^0.8) (Pr^0.35) ( / )
F

Nu= 0.023(7,299.7204^0.8)(0.729^0.33)(2.65*10^-5 Pa*s / 2.75^-6 Pa*s)


Nu= 0.023 (1232.0972) (0.8953) (9.6363)
Nu= 244.48

Despejando la ecuacin de Nusselt


obtenemos:

h= Nu K / D
h= 244.48 (0.03959 w/ mK) (0.0254m)
h= 381.06 w/m^2 K

Ejercicio1:
Mireya Carranza
Miriam Pulido
Liliana Prez
Ejercicio2:
Carlos Sal Gonzlez Ziga.
Eduardo Camacho.
Ejercicio 3:
Elizabeth Espino Irineo
Mara Noem Flores Gaytn
Mayra Gabriela Mandujano
Nadia Elisa Morales Estudillo
Ejercicio 4:
Mara Elena Vzquez Galvn.
Jazmn Moreno Fierro.
Yvette Hernndez Prez.

Anexo:
Ejercicio 6:
Mara Alejandra Hernndez Rubio
Eva Cruz Lpez
Guadalupe Prez Gonzlez
Mara Kasandra Snchez Jurez
Mara Florentina Hernndez cervantes
Jos Antonio Morales Snchez.

Ejercicio 5,7:
Claudia Cecilia Coln Torres.
Ana Patricia Len Rodrguez.

Ejercicio 8:
Huramo Tovar Marco Antonio
Jurez Toledo Alejandra
Silva Rodrguez Mario

You might also like