AVL DITEST MDS: MODULAR DIAGNOSTIC SYSTEM

Features, Function & Operation


performed by MDS

ECU Diagnostics

EOBD Reading

High Voltage-
Measurement

Engine and
Component Test

Emission

Info System

25.02.18 | Page 1
WHY TO SETTLE FOR LESS?

 The top product


 Modern design meets
functionality
 The latest generation of
endurance

AVL DITEST MDS: The reference… from the market leader!


25.02.18 | Page 2
AVL DITEST MDS: MODULAR DIAGNOSTIC SYSTEM

HV Measurement
ECU Diagnostics Hotline

Emission petrol

Guided diagnostice
Auxillary functions

Emission Diesel
Emission Emission
Diesel Petrol

EOBD Reading

ECU HV-
Diagnostics Measurement Auxillary
Hotline AVL DSS
functions

Info system
Engine and
Info
system

component Trolley
testing

Engine and component


testing

PC
Customer owned
systems

25.02.18 | Page 3
AVL DITEST MDS: MODULES
AVL DITEST Gas 1000

AVL DITEST Gas 1000


Module for measuring petrol
exhaust emissions (CO,
COcorre, HC, HCcorre, RHC,
NMHC, CO2, O2, Dilustation,
and Lambda).

Product benefits:
 High-precision IR- measurement
bench according to OIML R99
class 00
 Suitable for use under exposure
to external condensation
 Optional Nox measurement
 MID Homologation
 Bluetooth connectivity
25.02.18 | Page 4
Exhaust Gas Flow Diagram for GAS 1000

25.02.18 | Page 5
Definition of Lambda () Value
Air quantity effectively available in combustion chamber
Lambda () =
Air quantity necessary for complete combustion of the
gasoline in the combustion chamber

Lambda > 1: Excess air, lean mixture

Lambda = 1: Exact quantity of air for complete combustion,


stoichiometric mixture

Lambda < 1: Excess gasoline, rich mixture

25.02.18 | Page 6
Calculation of Lambda According to Brettschneider
Emission of Petrol Vehicles, Sales Meeting 2000, 0500-7

Lambda = A1 . A2 with
the following simplifications are done,

x = Ambient air humidity in kg water vapour / kg air = very low


A1 = 1
WCV = Ratio of water to carbon (fuel) = 0
OCV = Atomar ratio of oxygen to carbon in the fuel = 0.0175
HCV = Atomar ratio of hydrogen to carbon in the fuel = 1.7261
K = Water-gas equilibrium constant = 3.5
K1 = Conversion factor for NDIR-HC-values (in ppm n-Hexan)
to FID-equivalent values (% vol C1) ≈ 6. 10-4
NO = Nitrogen monoxide ≈ opp. at idle

21
A1 = CO/CO2
21 + 50 x .
K + CO/CO2

K OCV . WCV
CO2 + CO/2 + O2 +NO/2 + (HCV/4 . - ) (CO2 + CO) - .
(...)
K + CO/CO2 2 2
A2 =
(1 +HCV/4 - OCV/2) . (CO2 + CO + K1 . HC)
80000

25.02.18 | Page 7
Lambda & AFR relation

Lambda
Most practical AFR devices actually measure the amount of residual oxygen (for lean
mixes) or unburnt hydrocarbons (for rich mixtures) in the exhaust gas. Lambda (λ) is
the measure of how far from stoichiometry that mixture is. Lambda of 1.0 is at
stoichiometry, rich mixtures are less than 1.0, and lean mixtures are greater than 1.0.
There is a direct relationship between lambda and AFR. To calculate AFR from a given
lambda, multiply the measured lambda by the stoichiometric AFR for that fuel.
Alternatively, to recover lambda from an AFR, divide AFR by the stoichiometric AFR for
that fuel. This last equation is often used as the definition of lambda:
Lambda=AFR/AFR stoich.
Because the composition of common fuels varies seasonally, and because many
modern vehicles can handle different fuels, when tuning, it makes more sense to talk
about lambda values rather than AFR
Stoich for different fuels are
Gasoline (Petrol) =14.7
Diesel=14.6
Methane=6.4
Ethanol=9.1
Propane (LPG) =15.5
Natural Gas (CNG)=17.2
Hydrogen=34

25.02.18 | Page 8
Significant of COcorr, HCcorrec & Dilution.

COcorr is a calculated value (using Co and CO2 measured values as per below formula) to
check whether there is a dilution or not.

Use of COcorrec: Compare the actual


measured CO value and the COcorr value.

•If both values were the same there is no dilution


•If both values were different there is a dilution

This calculation will work as soon as the


measured CO value > 0 (see formula).

We speak about dilution if the exhaust gas is mixed up with air which does not come out from
the combustion. Possible causes for a dilution could be:
Leakage (e.g. hole) in the exhaust pipe & Pulsing of an exhaust system.

That means: Every 4 stroke engine has 4 working stroke – Intake, Compression, Power, & Exhaust

For low cylinder engines (1 cylinder 4 stroke bikes) it is possible that during the strokes 1, 2, 3
fresh air is sucked in on the back of the exhaust pipe. 25.02.18 | Page 9
AVL DITEST MDS: MODULES
AVL DITEST Gas 1000

AVL DiSmoke 480 BT


Module for the measurement of
diesel emission (k-value and opacity)

Product benefits:
 Compact, lightweight and low-
maintenance opacity meter
 Wireless signal link via Bluetooth .
 Patented linearity test; automatic
verification of readiness for use
without filter test
 Only one probe for all exhaust pipe
diameters (passenger vehicles,
trucks)
 Extremely Short warm-up phase –
quick response time 25.02.18 | Page 10
Opacity Measurement principle for DISMOKE 480 BT
Passage of a beam of light through the exhaust gases in the instrument measuring
chamber, measurement of its intensity and comparison with its original intensity

Lichtquelle
Detektor

Partikelstrom

Einfallender
Lichtstrahl
Streulicht

25.02.18 | Page 11
AVL DITEST MDS: MODULES
AVL DITEST Gas 1000

AVL DITEST AUX 2000


Module for auxiliary measurements
such as RPM and oil temperature.

Product benefits
 Based on proved AVL DiSpeed 492
technology (Acoustic & vibration)
 without settings and with the least
effort to the correct engine speed
 Best coverage
 Automatic self-calibration and
function monitoring
 Bluetooth connectivity

25.02.18 | Page 12
Unique feature of MDS 450

 Windows base open loop system – All feature of OS (MS office for data analyses)
& PC hardware (Big display, network etc.) are available for application
 Real time data measurement (50mSec) – Best suited for dynamic vehicle test
condition; carburetor, dwell angle & gas kit setting
 Class 00 measuring bench for gas– Highly accurate measurement
 Laser & Photodiode as detector for opacity – Highly accurate measurement
 MID, EPA, ARAI etc. certification requirements is fulfilled – Best suited single
instrument for world wide official measurement\
 Zero warm-up time – Very fast response, minimal initialization time, continue
measuring capability without IR & HC test for gas analyzer
 215 mm measuring chamber – Very fast response, minimal initialization time,
continues measurement without white balancing.
 SQL data base – Secures test results.
 Inbuilt memory; user configurable storage memory for data storage - No storage
space concerns.
 Printer – Laser & POS printer compatible for fast printout of text & Graphics
 Calibration is required once in a year – Very high reliability
 Optional features like ECU flashing, read, erase & reset can be done along with
combustion pressure.
 Customized testing cycle & user define measurement limits can be set, Test
cycle & results can be read by symbol reader -Barcode

25.02.18 | Page 13
AVL DiX/MDS/CDS at Glance
(CDS is available only in under model 250, 350, 450 & 550 only)

25.02.18 | Page 14