You are on page 1of 10

© VimpelCom Ltd 2012

Dynamic SDCCH Algorithm


B/m is TCH ~ Dynamic SDCCH algorithm:

 If the number of idle SDCCHs in the cell is smaller than or equal to the value of Idle SDCCH Threshold N1
,the BSC tries to find a TCHF that can be converted to the SDCCH.

if number of idle SDCCH TSs <= Idle SDCCH Threshold N1


© VimpelCom Ltd 2012

 Now BSC will check following three conditions for initiating the conversion from TCHFs to SDCCHs:

 The cell allows the SDCCH dynamic adjustment


 (Number of idle TCHFs + number of idle TCHHs/2) ≥ 4 or the number of TRXs in the cell, and the cell must have
at least one idle TCHF
 The sum of the number of SDCCHs in the cell plus eight is smaller than the maximum number of SDCCHs
allowed in the cell

When all a/m conditions are true then

Convert TCHF >>>>>>>>> Dynamic SDCCH


TCH Recovery Algorithm
 Dynamic SDCCH to TCH conversion back algorithm is given below:

 Each cell is configured with a counter S. Each time the TCH is converted to the SDCCH, the counter is set to ResTime.
The value of the counter is adjusted every three seconds.

Where ResTime = TCH Min Recovery Time [Minimum time for the recovery of a TCH from SDCCH]
© VimpelCom Ltd 2012

If
Number of Idle SDCCHs > 8 + Idle SDCCH Threshold N1
[S decreased by 3]

If
Number of Idle SDCCHs < 8 + Idle SDCCH Threshold N1
[S increased by 12 but not above than TCH recovery Time]

If
Number of Idle SDCCHs = 8 + Idle SDCCH Threshold N1
[S is unchanged]

If the value of the counter S is equal to or lower than 0 after adjustment, the SDCCH is converted to the TCH.
© VimpelCom Ltd 2012

Related Parameters
Dynamic Allocation Enabled
© VimpelCom Ltd 2012
Cell SDCCH Channel Maximum
© VimpelCom Ltd 2012
Idle SDCCH Threshold N1
© VimpelCom Ltd 2012
TCH Minimum Recovery Time(s)
© VimpelCom Ltd 2012
EID Sample WO [For Reference]
 Dynamic SDCCH sample WO for EID is pasted below for reference:
© VimpelCom Ltd 2012

Idle SDCCH Threshold N1


BSC Cell Index Cell Name CI
Current Proposed
ISB644H__I-10_Building_ISB_1 44 ISB0232__H_G61 232 2 8
ISB644H__I-10_Building_ISB_1 7 ISB10005__S_Parliament_Lodges 10005 2 8
ISB650H__I-10_Building_ISB_4 237 ISB10013__P_F103 10013 2 8
© VimpelCom Ltd 2012