Professional Documents
Culture Documents
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page1
Contents
1. Network application and system structure
2. Sub-rack
3. Equipment Cards
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page2
Network Application
OptiX OSN 9500
OptiX OSN 7500 OptiX OSN 7500
Core
Convergence
layer
Access layer
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page3
System Structure
STM-1/STM-4 , E1 IU1 IU1 STM-1/STM-4 ,E1
STM-1/STM-4 STM-1/STM-4
Ethernet E1
IU2 IU2 Ethernet , E1
Cross-connect
STM-1/STM-4 STM-1/STM-4
IU3 Unit IU3
Ethernet , E1 Ethernet , E1
16×16VC4
Ethernet ,E1 IU4 IU4 Ethernet , E1
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page4
System function
Weight : 8Kg
Multi-protection
ATM-VP-ring/SDH Protection
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page5
Contents
1. Network application and system structure
2. Sub-rack
3. Equipment Cards
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page6
Sub-rack
The dimensions of the chassis are 436 mm (W) x 293 mm (D) x 86 mm (H).
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page7
Sub-rack (Cont.)
1. 2. Fan 3. Board 3
Board Assignment
SCB
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page8
Contents
1. Network application and system structure
2. Sub-rack
3. Equipment Cards
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page9
Equipment Cards
PDH Unit
Ethernet Unit
SDH Unit
SCB Unit
Power Unit
Fan Unit
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page10
PDH Unit
Board Full name Available slot Interface type
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page11
PDH Unit (Cont.)
SP1S/SP1D
SP2D
PD2T
PD2D
PD2S
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page12
PDH Unit (Cont.)
Alarm name Alarm description Alarm level
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page13
Ethernet Unit (Cont.)
Board ET1 ET1O EF1 ET1D EFT ELT2 EGT
Access and 4 x FE ( E )
2 x FE
processing 8 x FE 8 x FE + 2 x FE 4× FE 1×GE
(O)
capacity 2×FE ( O)
Max Vctrunk
16 4 2 1
number
2×VC4 (6 x VC-3, or 63 x
Bandwidth 48×E1 16×E1
VC-12 + 3 x VC-3 )
Slots available IU4 IU2, IU3
Connector RJ45 RJ45, LC RJ45 LC SFP
Services types
EPL EPLAN EPL
available
Eth II,
Frame structure Eth II, 802.3, 802.1Q Eth II, 802.3
802.3
Encapsulation ML-PPP GFP/LAPS/HDLC
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page14
Ethernet Unit (Cont.)
ET1,
ET1O ALM RUN
2 1
ET1D
ALM RUN
EF1
ALM RUN
EFT g
LINK LINK
ACT
ELT2 ACT
EGT
LINK
CLASS
EGT
LASE
ACT PRODU
R
1
CT
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page15
Ethernet Unit (Cont.)
Board EFS EFSC EGS
Access and
4 x FE 12 x FE 1 x GE
processing capacity
Max Vctrunk number 24
Bandwidth 4×VC4 (12 x VC-3, or 126 x VC-12 + 6 x VC-3 )
Slots available IU2, IU3 IU4 IU2, IU3
Connector RJ45 SFP
Services types
EPL/EVPL/EPLAN/EVPLAN
available
Frame structure Ethernet II, 802.3, 802.1Q, MPLS Martini
Encapsulation GFP
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page16
Ethernet Unit (Cont.)
RUN
ALM
EFS
RUN
EFSC ALM
RUN LINK
ALM ACT
EGS
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page17
Ethernet Unit (Cont.)
No. Silkscreen Description Remarks
1 - Network interface The indicator (yellow) is on when data is passing by the network interface link.
running indicator
2 - Network interface link The indicator (green) is on when the network interface connects with a network
indicator cable.
3 RUN Board running On for 100ms and off for 100ms: The board is not in service.
indicator
On for two seconds and off for two seconds: The board is offline.
On for one second and off for one second: The board works normally.
The alarm indicator and the running indicator are on for one second and off for
one second at the same time: Waiting for loading software.
The alarm indicator and the running indicator are on for 100ms and off for
100ms at the same time: Loading software.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page18
Ethernet Unit (Cont.)
Alarm Name Alarm description Level
Critica
ETH_LOS Ethernet link down
l
Critica
PROTOCOL_MM Encapsulation protocol mismatched
l
IU1、IU2、
OI2S 1-channel STM-1 optical interface board SC/PC
IU3
IU1、IU2、
OI2D 2-channel STM-1 optical interface board SC/PC
IU3
IU1、IU2、
OI4 1-channel STM-4 optical interface board SC/PC
IU3
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page20
SDH Unit (Cont.)
For SB2D the left optical interface transmits at 1550 nm and receives at
1310 nm; the right optical interface transmits at 1310 nm and receives at
1550 nm.
SB2L has a left optical interface only, which transmits at 1550 nm and
receives at 1310 nm.
SB2R has a right optical interface only, which transmits at 1310 nm and
receives at 1550 nm. OptiX 155/622H
Tx: 1310 nm Rx: 1310 nm
Rx: 1550 nm SB2D Tx: 1550 nm
Rx: 1310 nm Tx: 1310 nm
Tx: 1550 nm Rx: 1550 nm
SB2 SB2R
OptiX 155/622H SB2 SB2L OptiX 155/622H
L
Tx: 1310 nmR S S Rx: 1310 nm
Rx: 1550 nm Rx: 1310 nm B B Tx: 1550 nm
2 2 Tx: 1310 nm
Tx: 1550 nm L R Rx: 1550 nm
OptiX 155/622H One single fiber
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page21
SDH Unit (Cont.)
Fiber connection indicator
OI2S/OI4
155M 622M
I-1(4).0 S-1(4).1
L-1(4).1 L-1(4).2
(a)
West East
OI2D
(b)
155M 622M
I-1(4).0 S-1(4).1 Type of the
L-1(4).1 L-1(4).2 interface.
Rate:STM-1.
Long distance.
Wavelength:1310n
m
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page22
SDH Unit
Interface
Board Full name Available slot
type
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page23
SDH Unit (Cont.)
Functions of SDH cards
Access and process STM-1/4 optical/Electrical signals.
Support optical interface inloop and outloop for fast fault location.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page24
SDH Unit
Alarm name Alarm description Alarm level
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page25
SDH Unit
Alarm name Al/arm description Alarm level
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page26
SCB
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page27
SCB
Functions of SCB card
Provide cross-connection function.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page28
SCB (Cont.)
IP address & ID
How is the network element ID designed?
The low 8 digits and high 4 digits from right to left of the 16 DIP switch group
are used representing ID of NE..
ON
OFF
D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page29
SCB (Cont.)
Alarm name Alarm description Alarm level
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page30
Contents
1. Network application and system structure
2. Sub-rack
3. Equipment Cards
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page31
Common Network Elements
Terminal multiplexer (TM)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page32
TM
STM-1/4/16/64
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page33
TM (Cont.)
Applications:
Point-to-Point Network TM TM
Chain Network
ADM
ADM ADM TM
ADM
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page34
TM (Cont.)
Configure a TM:
Tributary Unit : 48X2M
PD2T: IU 4
OI2S: IU 1
IU4-PD2T
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page35
ADM
STM-1/4/16/64 STM-1/4/16/64
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page36
ADM (Cont.)
Applications:
Chain Network
Ring Network
TM ADM ADM TM
ADM
ADM AD
M
ADM
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page37
ADM (Cont.)
Configure an ADM:
Tributary Unit : 48X2M
PD2T: IU4
OI2S: IU1,IU2
IU4-PD2T
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page38
MADM
MADM
ADM ADM
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page39
MADM (Cont.)
STM-1/4/16/64 STM-1/4/16/64
...
STM-1/4/16/64 STM-
1/4/16/64
Low-rate SDH
signal
PDH signal. etc.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page40
MADM (Cont.)
Configure a double ADM:
Tributary Unit : 48X2M
PD2T: IU4
OI2S: IU1,IU2
OI2D: IU3
IU3-OI2D IU2-OI2S IU1-OI2S
IU4-PD2T
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page41
Contents
1. Network application and system structure
2. Sub-rack
3. Equipment Cards
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page42
Equipment Level Protection
Power input unit 1+1 hot backup
Grounding terminal
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page43
Network Level Protections (Cont.)
Linear MSP
Is mainly used in linear network topology.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page44
Network Level Protections (Cont.)
MSP Ring
CA AC
S1/P2
S2/P1
A
B D
C
S2/P1
S1/P2
CA AC
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page45
Network Level Protections (Cont.)
SNCP
Sub-network
Working
SNC 1
SNC SNC
Termination
Starting Node
Node
Selector
NE A Protection NE B
SNC
Sub-network
2
SNCP Protection
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page46
Network Level Protections (Cont.)
Protection for Inter-Ring Services
When there are more than one routes existing between the
rings, inter-ring service protection can be enabled.
SNCP and MSP ring, SNCP and SNCP ring
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page47
Network Level Protections (Cont.)
Fiber-Shared Virtual Trail Protection
The left ring and the right ring will share the fiber.
STM-4
STM-4
STM-1 STM-1
SNCP SNCP
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page48
Summary
Product Introduction
Features
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page49
Thank you
www.huawei.com
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page50