You are on page 1of 51

OptiX 155622H(Metro

1000) V200 Hardware


Description
www.huawei.com

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.


Objectives
 Upon completion of this course, you will be able to:
 Describe the network applications of the OptiX 155/622H(Metro
1000)
 Explain the system structure and features of the OptiX
155/622H(Metro 1000)
 State the main functions of the cards in the OptiX
155/622H(Metro 1000)
 Outline the system protection modes of the OptiX
155/622H(Metro 1000)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page1
Contents
1. Network application and system structure

2. Sub-rack

3. Equipment Cards

4. Common Network Elements and Configuration

5. Equipment Level and Network Level Protection

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page2
Network Application
OptiX OSN 9500
OptiX OSN 7500 OptiX OSN 7500

Core

OptiX OSN 3500 OptiX OSN 3500

Convergence
layer

OptiX OSN 1500 OptiX OSN 1500

Access layer

OptiX Metro 1000 OptiX Metro 1000


Network
terminal unit
OptiX Metro OptiX Metro
100 100
Switching /
Ethernet
Base Station

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page3
System Structure
STM-1/STM-4 , E1 IU1 IU1 STM-1/STM-4 ,E1

STM-1/STM-4 STM-1/STM-4
Ethernet E1
IU2 IU2 Ethernet , E1
Cross-connect
STM-1/STM-4 STM-1/STM-4
IU3 Unit IU3
Ethernet , E1 Ethernet , E1
16×16VC4
Ethernet ,E1 IU4 IU4 Ethernet , E1

Clock unit SCC unit Orderwire unit

external clock interface NM interface Orderwire phone

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page4
System function
 Weight : 8Kg

 Power Consumption : 82 w( Full Equipped )

 Maximum Service Access Capability


 3×STM-4,6×STM-1(O/E)

 80×E1,14×FE(O/E, Layer 2 Switch),9×E3(75Ω)

 Multi-protection
 ATM-VP-ring/SDH Protection

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page5
Contents
1. Network application and system structure

2. Sub-rack

3. Equipment Cards

4. Common Network Elements and Configuration

5. Equipment Level and Network Level Protection

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page6
Sub-rack

ETN: Ethernet indicator

RUN: Running indicator


R: Critical alarm indicator
Y: Major alarm indicator
FAN: Fan alarm indicator

The dimensions of the chassis are 436 mm (W) x 293 mm (D) x 86 mm (H).

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page7
Sub-rack (Cont.)

1. 2. Fan 3. Board 3

Chassis board area 4

4. Power filter board

Board Assignment

IU3 IU2 IU1

FAN IU4 POI

SCB

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page8
Contents
1. Network application and system structure

2. Sub-rack

3. Equipment Cards

4. Common Network Elements and Configuration

5. Equipment Level and Network Level Protection

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page9
Equipment Cards
 PDH Unit

 Ethernet Unit

 SDH Unit

 SCB Unit

 Power Unit

 Fan Unit

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page10
PDH Unit
Board Full name Available slot Interface type

4-channel E1 electrical 120 ohm/75 ohm E1


SP1S IU2 IU3
interface board interface

8-channel E1 electrical 120 ohm/75 ohm E1


SP1D IU2 IU3
interface board interface

16-channel E1 electrical 120 ohm/75 ohm E1


SP2D IU2 IU3
interface board interface

16-channel E1 electrical 120 ohm/75 ohm E1


PD2S IU4
interface board interface

32-channel E1 electrical 120 ohm/75 ohm E1


PD2D IU4
interface board interface

48-channel E1 electrical 120 ohm/75 ohm E1


PD2T IU4
interface board interface

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page11
PDH Unit (Cont.)
SP1S/SP1D

SP2D

PD2T

PD2D

PD2S

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page12
PDH Unit (Cont.)
Alarm name Alarm description Alarm level

BD_STATUS Board not in position alarm Major

HP_LOM Higher order path loss of multiframe Major

T_ALOS Loss of 2M interface analog signal Major

TU_AIS TU alarm indication signal Major

TU_LOP TU loss of pointer Major

LP_PS Lower order path switching Major

BIP_EXC BIP bit error excessive Minor

BIP_SD BIP signal deterioration Minor

LOOP_ALM Loop alarm Minor

LP_RDI Lower order path remote defect indication Minor

LP_REI Lower order path-remote error indication Minor

LP_UNEQ lower order path unequipped error Minor

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page13
Ethernet Unit (Cont.)
Board ET1 ET1O EF1 ET1D EFT ELT2 EGT
Access and 4 x FE ( E )
2 x FE
processing 8 x FE 8 x FE + 2 x FE 4× FE 1×GE
(O)
capacity 2×FE ( O)
Max Vctrunk
16 4 2 1
number
2×VC4 (6 x VC-3, or 63 x
Bandwidth 48×E1 16×E1
VC-12 + 3 x VC-3 )
Slots available IU4 IU2, IU3
Connector RJ45 RJ45, LC RJ45 LC SFP
Services types
EPL EPLAN EPL
available
Eth II,
Frame structure Eth II, 802.3, 802.1Q Eth II, 802.3
802.3
Encapsulation ML-PPP GFP/LAPS/HDLC

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page14
Ethernet Unit (Cont.)
ET1,
ET1O ALM RUN

2 1

ET1D
ALM RUN

EF1
ALM RUN

EFT g

LINK LINK
ACT
ELT2 ACT

EGT
LINK
CLASS

EGT
LASE
ACT PRODU
R
1

CT

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page15
Ethernet Unit (Cont.)
Board EFS EFSC EGS
Access and
4 x FE 12 x FE 1 x GE
processing capacity
Max Vctrunk number 24
Bandwidth 4×VC4 (12 x VC-3, or 126 x VC-12 + 6 x VC-3 )
Slots available IU2, IU3 IU4 IU2, IU3
Connector RJ45 SFP
Services types
EPL/EVPL/EPLAN/EVPLAN
available
Frame structure Ethernet II, 802.3, 802.1Q, MPLS Martini
Encapsulation GFP

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page16
Ethernet Unit (Cont.)
RUN

ALM

EFS

RUN

EFSC ALM

RUN LINK

ALM ACT
EGS

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page17
Ethernet Unit (Cont.)
No. Silkscreen Description Remarks

1 - Network interface The indicator (yellow) is on when data is passing by the network interface link.
running indicator

2 - Network interface link The indicator (green) is on when the network interface connects with a network
indicator cable.

3 RUN Board running On for 100ms and off for 100ms: The board is not in service.
indicator
On for two seconds and off for two seconds: The board is offline.

On for one second and off for one second: The board works normally.

4 ALM Board alarm indicator Off: No alarm.

Flash three times every other second: Critical alarm.

Flash twice every other second: Major alarm.

Flash once every other second: Minor alarm.

The alarm indicator and the running indicator are on for one second and off for
one second at the same time: Waiting for loading software.

The alarm indicator and the running indicator are on for 100ms and off for
100ms at the same time: Loading software.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page18
Ethernet Unit (Cont.)
Alarm Name Alarm description Level

Critica
ETH_LOS Ethernet link down
l

Critica
PROTOCOL_MM Encapsulation protocol mismatched
l

TU_AIS_VC3(VC12) TU alarm indication Major

TU_LOP_VC3(VC12) TU pointer lost Major

BIP_EXC BIP bit error excessive Minor

BIP_SD BIP signal deteriorates Minor

LOOPALM Loopback alarm Minor

Lower-order path remote receiving failure


LP_RDI_VC3(VC12) Minor
indication

LP_REI_VC3(VC12) Lower-order path remote bit error indication Minor


Copyright © 2006 Huawei Technologies
LP_UNEQ_VC3(VC12) Co., Ltd. All
Lower-order pathrights reserved.
unloaded Page19 Minor
SDH Unit
Boar
Full name Available slot Interface type
d

IU1、IU2、
OI2S 1-channel STM-1 optical interface board SC/PC
IU3

IU1、IU2、
OI2D 2-channel STM-1 optical interface board SC/PC
IU3

IU1、IU2、
OI4 1-channel STM-4 optical interface board SC/PC
IU3

Single-fiber 2-channel STM-1 interface IU1、IU2、


SB2D SC/PC
board IU3

Single-fiber 2-channel STM-1 interface IU1、IU2、


SB2L SC/PC
board IU3

Single-fiber 2-channel STM-1 interface IU1、IU2、


SB2R SC/PC
board IU3

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page20
SDH Unit (Cont.)
 For SB2D the left optical interface transmits at 1550 nm and receives at
1310 nm; the right optical interface transmits at 1310 nm and receives at
1550 nm.
 SB2L has a left optical interface only, which transmits at 1550 nm and
receives at 1310 nm.
 SB2R has a right optical interface only, which transmits at 1310 nm and
receives at 1550 nm. OptiX 155/622H
Tx: 1310 nm Rx: 1310 nm
Rx: 1550 nm SB2D Tx: 1550 nm
Rx: 1310 nm Tx: 1310 nm
Tx: 1550 nm Rx: 1550 nm
SB2 SB2R
OptiX 155/622H SB2 SB2L OptiX 155/622H
L
Tx: 1310 nmR S S Rx: 1310 nm
Rx: 1550 nm Rx: 1310 nm B B Tx: 1550 nm
2 2 Tx: 1310 nm
Tx: 1550 nm L R Rx: 1550 nm
OptiX 155/622H One single fiber

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page21
SDH Unit (Cont.)
Fiber connection indicator

OI2S/OI4

155M 622M
I-1(4).0 S-1(4).1
L-1(4).1 L-1(4).2

(a)
West East
OI2D

155M 622M 155M 622M


I-1(4).0 S-1(4).1 I-1(4).0 S-1(4).1
L-1(4).1 L-1(4).2 L-1(4).1 L-1(4).2

(b)

155M 622M
I-1(4).0 S-1(4).1 Type of the
L-1(4).1 L-1(4).2 interface.
Rate:STM-1.
Long distance.
Wavelength:1310n
m

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page22
SDH Unit
Interface
Board Full name Available slot
type

1-channel STM-4 electrical


SLE IU1、IU2、IU3 SMB
interface board

SDE 2-channel STM-4 electrical


IU1、IU2、IU3 SMB
interface board

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page23
SDH Unit (Cont.)
 Functions of SDH cards
 Access and process STM-1/4 optical/Electrical signals.

 Support I-1(4), S-1(4).1, L-1(4).1 and L-1(4).2 standard optical


modules.

 Support MSP, uni/bi-directional path protection and SNCP.

 Provide abundant alarm and performance events for convenient


equipment management and maintenance.

 Support optical interface inloop and outloop for fast fault location.

 Provide automatic laser shutdown (ALS) function.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page24
SDH Unit
Alarm name Alarm description Alarm level

R_LOF Loss of frame at receiving line side Critical

R_LOS Loss of signals at receiving line side Critical

MS_AIS Multiplex section alarm indication Major

APS_INDI Protection switching indication Major

AU_AIS AU alarm indication Major

AU_LOP AU loss of pointer Major

B2_EXC Excessive B2 bit errors Major

B3_EXC Excessive B3 bit errors Major

BD_STATUS Board not in position alarm Major

HP_LOM Higher order path loss of multiframe Major

MS_RDI Multiplex section remote defect indication Minor

HP_RDI Lower order path remote defect indication Minor

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page25
SDH Unit
Alarm name Al/arm description Alarm level

B1_EXC Excessive B1 bit errors Minor

B1_SD B1 signal deterioration Minor

B2_SD B2 signal deterioration Minor

B3_SD B3 signal deterioration Minor

HP_SLM Higher order path signal label mismatch Minor

HP_TIM Higher order path trace identifier mismatch Minor

HP_UNEQ Higher order unequipped Minor

J0_MM Mismatch of trace and identifier Minor

LOOP_ALM Loopback alarm Minor

MS_REI Multiplex section remote error indication Prompt

HP_REI Higher order path remote error indication Prompt

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page26
SCB

No. Silkscreen Description


1 SYNC 1/2 Two external clock input/output
2 RST RESET button
3 Equipment indicators Running and alarm indicators
4 16……………1 DIP switch
5 ALM CUT Audio and visual alarm cutoff switch
6 MODEM MODEM interface
7 RS-232 2 Serial communication port controlled by CPU
8 RS-232 1 Serial communication port controlled by CPU
9 F2 Network management interface
10 ETHERNET RJ-45 Ethernet interface
11 PHONE Orderwire phone interface

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page27
SCB
 Functions of SCB card
 Provide cross-connection function.

 Provide clock synchronization function.

 Detect and report performance events and alarms.

 Provide 10M/100M Ethernet NM interface.

 Provide embedded control channel (ECC).

 Provide a line of orderwire phone.

 Provide transparent data interfaces.


The system
Provide control board and
fan alarm (SCB) combines the SCC
management unit, cross-connect unit,
function.
clock unit, orderwire unit, Auxiliary unit.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page28
SCB (Cont.)
 IP address & ID
How is the network element ID designed?
The low 8 digits and high 4 digits from right to left of the 16 DIP switch group
are used representing ID of NE..

ON

OFF

D3 D2 D1 D0 D7 D6 D5 D4 D3 D2 D1 D0

If ID=9, the lower 12 digits DIP switch should be 0000 00001001

Note: This figure only shows us the right half

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page29
SCB (Cont.)
Alarm name Alarm description Alarm level

LTI Loss of all synchronization sources Major

SYNC_C_LOS Loss of higher level synchronization source Major

POWER_FAIL Power supply failure Major

FAN_FAIL Fan failure Major

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page30
Contents
1. Network application and system structure

2. Sub-rack

3. Equipment Cards

4. Common Network Elements and Configuration

5. Equipment Level and Network Level Protection

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page31
Common Network Elements
 Terminal multiplexer (TM)

 Add and drop multiplexer (ADM)

 Multi-add and drop multiplexer (MADM)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page32
TM

STM-1/4/16/64

Low-rate SDH signal


PDH signal. etc.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page33
TM (Cont.)
 Applications:
 Point-to-Point Network TM TM

 Chain Network

 Ring-Chain Combination TM ADM TM

ADM

ADM ADM TM

ADM

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page34
TM (Cont.)
 Configure a TM:
 Tributary Unit : 48X2M

PD2T: IU 4

 Line Unit : STM-1

OI2S: IU 1

IU3 IU2 IU1-OI2S

IU4-PD2T

IU9-X42 IU10-STG IU11-SCC IU12-OHP2

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page35
ADM

STM-1/4/16/64 STM-1/4/16/64

Low-rate SDH signal


PDH signal. etc.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page36
ADM (Cont.)
 Applications:
 Chain Network
 Ring Network

TM ADM ADM TM

ADM

ADM AD
M

ADM

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page37
ADM (Cont.)
 Configure an ADM:
 Tributary Unit : 48X2M

PD2T: IU4

 Line Unit : STM-1

OI2S: IU1,IU2

IU3 IU2-OI2S IU1-OI2S

IU4-PD2T

IU9-X42 IU10-STG IU11-SCC IU12-OHP2

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page38
MADM
MADM

ADM ADM

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page39
MADM (Cont.)
STM-1/4/16/64 STM-1/4/16/64

...

STM-1/4/16/64 STM-
1/4/16/64

Low-rate SDH
signal
PDH signal. etc.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page40
MADM (Cont.)
 Configure a double ADM:
 Tributary Unit : 48X2M

PD2T: IU4

 Line Unit : STM-1

OI2S: IU1,IU2

OI2D: IU3
IU3-OI2D IU2-OI2S IU1-OI2S

IU4-PD2T

IU9-X42 IU10-STG IU11-SCC IU12-OHP2

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page41
Contents
1. Network application and system structure

2. Sub-rack

3. Equipment Cards

4. Common Network Elements and Configuration

5. Equipment Level and Network Level Protection

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page42
Equipment Level Protection
 Power input unit 1+1 hot backup

Failed Power switch


Input PWR1
Power interface
Input PWR2
Power interface

Grounding terminal

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page43
Network Level Protections (Cont.)
 Linear MSP
 Is mainly used in linear network topology.

 Supports 1+1 and 1:N (1 ≤ N ≤ 3) protection schemes in the point-


to-point linear network topology.

 In the 1:N protection mode, additional services are supported.

1+1/1:1 Linear MS Protection

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page44
Network Level Protections (Cont.)
 MSP Ring

CA AC
S1/P2
S2/P1

A
B D
C
S2/P1
S1/P2

CA AC

Two Fiber MS shared protection Ring

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page45
Network Level Protections (Cont.)
 SNCP

Sub-network
Working
SNC 1
SNC SNC
Termination
Starting Node
Node

Selector

NE A Protection NE B
SNC
Sub-network
2

SNCP Protection

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page46
Network Level Protections (Cont.)
 Protection for Inter-Ring Services
 When there are more than one routes existing between the
rings, inter-ring service protection can be enabled.
 SNCP and MSP ring, SNCP and SNCP ring

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page47
Network Level Protections (Cont.)
 Fiber-Shared Virtual Trail Protection
 The left ring and the right ring will share the fiber.

 Both of the ring should be SNCP or uni-direction MSP ring

STM-4
STM-4

STM-1 STM-1
SNCP SNCP

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page48
Summary
 Product Introduction

 Cabinet, Sub-rack and Boards

 Common Network Elements and Configuration

 Features

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page49
Thank you
www.huawei.com

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page50

You might also like